COLUMBUS, OH —
OSHA Inspection: CAPITOL CITICOM, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of CAPITOL CITICOM, INC. in 2225 CITYGATE DRIVE SUITE A, COLUMBUS, OH 43219 (NAICS 323111). OSHA activity number 344617634.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CAPITOL CITICOM, INC.
- Site address
- 2225 CITYGATE DRIVE SUITE A
- City
- COLUMBUS
- State
- OH
- ZIP
- 43219
- Mailing
- 2225 CITYGATE DRIVE SUITE A, COLUMBUS, OH 43219
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 323111
- Employees
- 40
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C04 II B
- Issued
- Apr 22, 2020
- Abate by
- May 12, 2020
- Penalty
- Initial $5,398 · Current $5,398
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following: 29 CFR 1910.147(c)(4)(ii)(B): Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy; a. On or about February 6, 2020, located in the Bindery Department, the employer did not list the rules and techniques on energy control procedures pertaining to thermal hazards for XtraCoat UV Roller Coater printing press, model number XCF 29-1-3A, serial number CON-1615 that was associated with performing service and maintenance tasks. There were no specific procedural steps for the safe shutdown and isolation of the thermal energy to protect the employees from the UV light heat, thereby exposing employees to burn hazards.
Recent events (2)
- — I (S) $5398
- — Z (S) $5398
1910.147 D
- Issued
- Apr 22, 2020
- Abate by
- May 12, 2020
- Penalty
- Initial $9,446 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence: a. On or about February 6, 2020, located in the Bindery Department, employees were exposed to machine hazards associated with moving parts, in-going nip points, and thermal hazards during servicing and cleaning the XtraCoat UV Roller Coater printing press, model number XCF 29-1-3A, serial number CON-1615. The employer failed to implement energy control application steps as the machine was not shut down or turned off to perform the servicing [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards. On February 6, 2020, an employee bypassed a guard to the lockout activity of cleaning print rollers on the XtraCoat UV Roller Coater printing press, model number XCF 29-1-3A, serial number CON-1615. Lockout/tagout was not performed prior to cleaning the rollers resulting in a fingertip injury.
Recent events (2)
- — I (S) $0
- — Z (S) $9446
1910.147 C06 I
- Issued
- Apr 22, 2020
- Abate by
- May 12, 2020
- Penalty
- Initial $6,747 · Current $6,747
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed. a. On or about February 6, 2020, located in the Bindery Department, the employer did not conduct a periodic inspection of the energy control procedures at least annually, thereby exposing employees to the hazards associated with servicing and maintenance activities on machines and equipment, i.e. electrical shock/electrocution, caught-in/caught-between hazards, etc.
Recent events (2)
- — I (S) $6747
- — Z (S) $6747
1910.147 C07 I A
- Issued
- Apr 22, 2020
- Abate by
- May 12, 2020
- Penalty
- Initial $9,446 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control. a. On or about February 6, 2020, located in the Bindery Department, employees performed service and maintenance activities on machines and equipment without receiving authorized employee lockout/tagout training. There employees were not able to recognize hazardous energy sources, type and magnitude of the energy available, and the methods and means for energy isolation and control exposing the employees to the unexpected energization or startup of the equipment or release of hazardous energy.
Recent events (2)
- — I (S) $0
- — Z (S) $9446
More inspections at Capitol Citicom, INC.
View Capitol Citicom, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 323111)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344617634.