On , OSHA opened a referral safety inspection of CAPITOL CITICOM, INC. in 2225 CITYGATE DRIVE SUITE A, COLUMBUS, OH 43219 (NAICS 323111). OSHA activity number 344617634.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Capitol Citicom, INC. — free Get an email when a new federal OSHA severe-injury report for Capitol Citicom, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2225 CITYGATE DRIVE SUITE A
City
COLUMBUS
State
OH
ZIP
43219
Mailing
2225 CITYGATE DRIVE SUITE A, COLUMBUS, OH 43219
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
323111
Employees
40
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 II B

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 22, 2020
Abate by
May 12, 2020
Penalty
Initial $5,398 · Current $5,398
29 CFR 1910.147(c)(4)(ii): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following:  29 CFR 1910.147(c)(4)(ii)(B): Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy;  a. On or about February 6, 2020, located in the Bindery Department, the employer did not list the rules and techniques on energy control procedures pertaining to thermal hazards for XtraCoat UV Roller Coater printing press, model number XCF 29-1-3A, serial number CON-1615 that was associated with performing service and maintenance tasks. There were no specific procedural steps for the safe shutdown and isolation of the thermal energy to protect the employees from the UV light heat, thereby exposing employees to burn hazards.
Recent events (2)
  • — I (S) $5398
  • — Z (S) $5398

1910.147 D

Serious Gravity 10 1 instance 3 exposed
Issued
Apr 22, 2020
Abate by
May 12, 2020
Penalty
Initial $9,446 · Current $0 Reduced
29 CFR 1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence:  a. On or about February 6, 2020, located in the Bindery Department, employees were exposed to machine hazards associated with moving parts, in-going nip points, and thermal hazards during servicing and cleaning the XtraCoat UV Roller Coater printing press, model number XCF 29-1-3A, serial number CON-1615. The employer failed to implement energy control application steps as the machine was not shut down or turned off to perform the servicing [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.  On February 6, 2020, an employee bypassed a guard to the lockout activity of cleaning print rollers on the  XtraCoat UV Roller Coater printing press, model number XCF 29-1-3A, serial number CON-1615. Lockout/tagout was not performed prior to cleaning the rollers resulting in a fingertip injury.
Recent events (2)
  • — I (S) $0
  • — Z (S) $9446

1910.147 C06 I

Serious Gravity 5 1 instance 40 exposed
Issued
Apr 22, 2020
Abate by
May 12, 2020
Penalty
Initial $6,747 · Current $6,747
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.   a. On or about February 6, 2020, located in the Bindery Department, the employer did not conduct a periodic inspection of the energy control procedures at least annually, thereby exposing employees to the hazards associated with servicing and maintenance activities on machines and equipment, i.e. electrical shock/electrocution, caught-in/caught-between hazards, etc.
Recent events (2)
  • — I (S) $6747
  • — Z (S) $6747

1910.147 C07 I A

Serious Gravity 10 1 instance 40 exposed
Issued
Apr 22, 2020
Abate by
May 12, 2020
Penalty
Initial $9,446 · Current $0 Reduced
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.   a. On or about February 6, 2020, located in the Bindery Department, employees performed service and maintenance activities on machines and equipment without receiving authorized employee lockout/tagout training. There employees were not able to recognize hazardous energy sources, type and magnitude of the energy available, and the methods and means for energy isolation and control exposing the employees to the unexpected energization or startup of the equipment or release of hazardous energy.
Recent events (2)
  • — I (S) $0
  • — Z (S) $9446