MANSFIELD, OH —
OSHA Inspection: RUSSELL T BUNDY ASSOCIATES, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of RUSSELL T BUNDY ASSOCIATES, INC. in 1711 N. MAIN ST., MANSFIELD, OH 44903 (NAICS 332812). OSHA activity number 344625181.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RUSSELL T BUNDY ASSOCIATES, INC.
- Site address
- 1711 N. MAIN ST.
- City
- MANSFIELD
- State
- OH
- ZIP
- 44903
- Mailing
- 417 E. WATER ST. P.O. BOX 150, URBANA, OH 43078
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332812
- Employees
- 20
- Ownership type
- A
Citations
10 citations on file for this inspection.
5(a)(1)
- Issued
- Apr 16, 2020
- Abate by
- Jun 30, 2020
- Penalty
- Initial $6,940 · Current $3,470 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that employees were exposed to struck-by hazards: a. Russell T Bundy Associates, Inc. - Mansfield, OH: On or about February 12, 2020, employees were exposed to struck/crush-by hazards in that the spreader bar, used as an under-the-hook lifting device with the north hoist on the west side of the tank line, was not marked with the device's rated capacity. The lifting device was used to transfer and dip baskets of parts at the tank line. b. Russell T Bundy Associates, Inc. - Mansfield, OH: On or about February 12, 2020, employees were exposed to struck/crush-by hazards in that the spreader bar, used as an under-the-hook lifting device with the south hoist on the west side of the tank line, was not marked with the device's rated capacity. The lifting device was used to transfer and dip baskets of parts at the tank line. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
- — I (S) $3470
- — Z (S) $6940
1910.106 E06 II
- Issued
- Apr 16, 2020
- Abate by
- Apr 29, 2020
- Penalty
- Initial $6,940 · Current $3,470 Reduced
General-duty citation text
29 CFR 1910.106(e)(6)(ii): Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), were dispensed into containers without the nozzle and container being electrically interconnected. Russell T Bundy Associates, Inc. - Mansfield, OH: On or about February 11, 2020, the employer did not ensure a metal 5-gallon Justrite parts cleaner can (model 27605) was bonded as Amerisolv, a category 2 flammable liquid, was being dispensed into the portable container.
Recent events (2)
- — I (S) $3470
- — Z (S) $6940
1910.132 A
- Issued
- Apr 16, 2020
- Abate by
- Apr 27, 2020
- Penalty
- Initial $10,409 · Current $5,204 Reduced
General-duty citation text
29 CFR 1910.132(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, were not provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact: a. Russell T Bundy Associates, Inc. - Mansfield, OH: On or about February 11, 2020, the employer did not ensure that employees who performed pouring operations in the smelting area wore flame resistant clothing to protect against burn injuries to the upper and lower body. Employees that tend the furnace were exposed to burn injuries from molten tin splash. b. Russell T Bundy Associates, Inc. - Mansfield, OH: On or about February 11, 2020, employees who performed pouring operations were exposed to burn injuries to their hands in that the heat resistant gloves were not maintained in a reliable condition. Holes in the gloves put employees at risk of burn injuries from molten tin splash.
Recent events (2)
- — I (S) $5204
- — Z (S) $10409
1910.132 D01 I
- Issued
- Apr 16, 2020
- Abate by
- Apr 27, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(1)(i): The employer did not select and have each affected employee use, the types of personal protective equipment that would protect the affected employee(s) from the hazards identified in the hazard assessment: Russell T Bundy Associates, Inc. - Mansfield, OH: On or about February 11, 2020, the employer did not perform an adequate hazard assessment to determine the proper protective equipment to be worn by employees exposed to burn injuries when conducting tin smelting and pouring operations.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.135 A01
- Issued
- Apr 16, 2020
- Abate by
- Apr 27, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.135(a)(1): The employer did not ensure that each affected employee wear a protective helmet when working in areas where there is a potential for injury to the head from falling objects: Russell T Bundy Associates, Inc. - Mansfield, OH: On or about February 11, 2020, the employer did not ensure that employees who performed smelting operations were provided with and wore head protection to protect against burn injury from molten metal splash. Employees were exposed to burn injury when pouring and tending the furnace.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.136 A
- Issued
- Apr 16, 2020
- Abate by
- Apr 27, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.136(a): The employer did not ensure that each affected employee used protective footwear when working in areas where there was a danger of foot injuries due to falling or rolling objects, or objects piercing the sole, and where such employee's feet were exposed to electrical hazards: Russell T Bundy Associates, Inc. - Mansfield, OH: On or about February 11, 2020, the employer did not ensure that employees were protected from foot injuries while performing smelting and pouring operations in that metatarsals and spats were not provided or used to protect the top of the foot from molten tin.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 I
- Issued
- Apr 16, 2020
- Abate by
- Apr 27, 2020
- Penalty
- Initial $10,409 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: Russell T Bundy Associates, Inc. - Mansfield, OH: On or about February 11, 2020, the employer did not ensure that employees who cleaned the glaze line were trained in the skills required for the safe application, usage, and removal of energy controls. Employees that used solvent to clean the equipment were not trained to isolate and/or render the electrical/mechanical energy source safe.
Recent events (2)
- — I (S) $0
- — Z (S) $10409
1910.147 D
- Issued
- Apr 16, 2020
- Abate by
- Apr 27, 2020
- Penalty
- Initial $10,409 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): Russell T Bundy Associates, Inc. - Mansfield, OH: On or about February 11, 2020, employees were exposed to injury from rotating parts in that the glaze line was not locked out prior to cleaning activities. The employer did not ensure energy control application steps to control the electrical/mechanical energy source were implemented prior to employees accessing hazard areas around rotating sprockets to clean glaze from the equipment - the employer did not: - Turn off or shut down the equipment. - Physically operate energy isolating devices to control energy sources and affix lockout device(s). - Ensure that all potentially hazardous stored or residual energy was relieved, disconnected, and rendered safe. - Verify that isolation and deenergization of the machine or equipment had been accomplished.
Recent events (2)
- — I (S) $0
- — Z (S) $10409
1910.212 A01
- Issued
- Apr 16, 2020
- Abate by
- Apr 29, 2020
- Penalty
- Initial $8,675 · Current $0 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: Russell T Bundy Associates, Inc. - Mansfield, OH: On or about February 11, 2020, the employer did not ensure that the vertical mixer associated with the Americoat reserve tank at the glaze line was adequately guarded to protect employees from rotating parts. Employees that accessed the top of the tank and/or opened the tank lid, were exposed to caught-in injuries created by the vertical pneumatic mixer.
Recent events (2)
- — I (S) $0
- — Z (S) $8675
1910.134 D01 III
- Issued
- Apr 16, 2020
- Abate by
- May 11, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form: Russell T Bundy Associates, Inc. - Mansfield, OH: On or about February 11, 2020, the employer did not conduct an evaluation to determine the respiratory hazards associated with working at the tank line. Employees were potentially exposed to hazards associated with diethylene glycol, 2-methylpentane-2,4-diol, potassium hydroxide, ethylene glycol phenyl ether, sodium metasilicate, and sodium tetraborate, such as, but not limited to, burns to the skin and eyes, irritation to the nasal and respiratory tract, eyes, throat, and skin.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Russell T Bundy Associates, INC.
View Russell T Bundy Associates, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332812)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344625181.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.