AMERY, WI ·
OSHA Inspection: RELIATRACE, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of RELIATRACE, INC. in 709 KELLER AVE S, AMERY, WI 54001 (NAICS 334510). OSHA activity number 344645056.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RELIATRACE, INC.
- Site address
- 709 KELLER AVE S
- City
- AMERY
- State
- WI
- ZIP
- 54001
- Mailing
- 709 KELLER AVE S, AMERY, WI 54001
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 334510
- Employees
- 60
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.147 C04 II B
- Issued
- May 27, 2020
- Abate by
- Jun 17, 2020
- Penalty
- Initial $9,446 · Current $5,668 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. (a) Punching area; The employer had not developed adequate procedures for isolating pneumatic energy source(s) on equipment such as but not limited to the D' Slugging machine.
Recent events (2)
- · I (S) $5668
- · Z (S) $9446
1910.147 D04 I
- Issued
- May 27, 2020
- Abate by
- Jun 17, 2020
- Penalty
- Initial $9,446 · Current $5,668 Reduced
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: (a) Punching area; A lock-out / tag-out device was not utilized on the D' Slugging machine to isolate the pneumatic energy when conducting service or maintenance work.
Recent events (2)
- · I (S) $5668
- · Z (S) $9446
More inspections in this industry (NAICS 334510)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 344645056.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.