BURLEY, ID —
OSHA Inspection: THE SPRINKLER SHOP, INC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of THE SPRINKLER SHOP, INC in HWY 30, MILE POST 146, BURLEY, ID 83318 (NAICS 237110). OSHA activity number 344647912.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- THE SPRINKLER SHOP, INC
- Site address
- HWY 30, MILE POST 146
- City
- BURLEY
- State
- ID
- ZIP
- 83318
- Mailing
- PO BOX 599, PAUL, ID 83347
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- Employees
- 3
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.21 B02
- Issued
- Mar 13, 2020
- Abate by
- Mar 19, 2020
- Penalty
- Initial $6,747 · Current $3,374 Reduced
General-duty citation text
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to the work environment to control or eliminate any hazards or other exposure to illness or injury: a) Jobsite: On February 21, 2020 and at times prior thereto employees worked in an area of an excavation without a cave-in protective system in place. Including the excavated spoil material, the area was 4 to 10 feet deep. Employees did not recognize or acknowledge the hazards of working in an unprotected area of an excavation or the actions needed to minimize or control the hazard. b) Jobsite: On February 21, 2020 and at times prior thereto a ladder or other safe means of egress was not available for employees working in an excavation. Employees did not recognize or acknowledge the hazard of not having safe egress out of the trench or take action to correct the hazard. c) Jobsite: On February 21, 2020 and at times prior thereto the excavated spoil material was not placed away from the top of the excavation. This made areas of the excavation up to 10 feet deep. Employees did not recognize or acknowledge this hazard and take action to minimize the hazard. Note) Certification of corrective actions are required for these items.
Recent events (2)
- — I (S) $3373.5
- — Z (S) $6747
1926.651 K01
- Issued
- Mar 13, 2020
- Abate by
- Mar 19, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems was not made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection was not conducted by the competent person prior to the start of work and as needed throughout the shift: a) Jobsite: On February 21, 2020 an at times prior thereto hazardous conditions were not identified and actions were not taken to correct or minimize the hazards before employees performed work in an excavation. The conditions included the spoil piles and other materials placed at or near the edge of the excavation, a proper cave-in protective system was not in place, and a safe means of egress was not available for employees. Note) The competent person definition applicable to this subpart means one who is capable of identifying existing and predictable hazards in the surroundings, or working conditions which are unsanitary, hazardous, or dangerous to employees, and who has authorization to take prompt corrective measures to eliminate them. Note) Certification is required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.651 C02
- Issued
- Mar 13, 2020
- Abate by
- Mar 19, 2020
- Penalty
- Initial $4,048 · Current $2,024 Reduced
General-duty citation text
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: a) Jobsite: On February 21, 2020 and at times prior thereto employees worked in a 4 to 10 foot deep excavation. A safe means of egress was not available. Employees used an area between a concrete wall and a vertical, excavated wall to climb out of the excavation. Note) Certification of corrective action is required for this item.
Recent events (2)
- — I (S) $2024
- — Z (S) $4048
1926.651 J02
- Issued
- Mar 13, 2020
- Abate by
- Mar 19, 2020
- Penalty
- Initial $6,747 · Current $3,374 Reduced
General-duty citation text
29 CFR 1926.651(j)(2): Employees were not protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations: a) Jobsite: On February 21, 2020 and at times prior thereto employees working in an excavation that was up to 10 feet deep, were exposed to excavated spoil material that was placed at the top of the excavation wall. Note) Certification of corrective action is required for this item.
Recent events (2)
- — I (S) $3373.5
- — Z (S) $6747
1926.652 A01
- Issued
- Mar 13, 2020
- Abate by
- Mar 19, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c) of this section: a) Jobsite: On February 21, 2020 and at times prior thereto employees worked in a 4 to 10 foot deep excavation to uncover phone and other power lines as part of the demolition of a concrete box. There was no cave-in protection system was in place. Note) Abatement certification is required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.417 A
- Issued
- Mar 13, 2020
- Abate by
- Mar 19, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.417(a): Controls that were to be deactivated during the course of work on energized or de-energized equipment or circuits were not tagged: a) Jobsite: On February 21, 2020 and at times prior thereto the control handle on the 480 volt control box for the irrigation system was in the OFF position. A tag was not placed on the control handle. Note) Certification of corrective action is required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at The Sprinkler Shop, INC