Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,195,903Inspections Most recent open 2026-08-18 Last loaded 2026-08-21

OSHA Inspection: WELSPUN TUBULAR, LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of WELSPUN TUBULAR, LLC in 9301 FRAZIER PIKE, LITTLE ROCK, AR 72206 (NAICS 331210). OSHA activity number 344649926.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Welspun Tubular, LLC for free Get an email when a new federal OSHA severe-injury report for Welspun Tubular, LLC is published. One employer, no account, unsubscribe in one click.
Site address
9301 FRAZIER PIKE
City
LITTLE ROCK
State
AR
ZIP
72206
Mailing
9301 FRAZIER PIKE, LITTLE ROCK, AR 72206
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331210
Employees
777
Ownership type
Private (A)

6 citations on file for this inspection.

1910.146 C01

Other-than-serious Gravity 5 1 instance 245 exposed
Issued
Aug 24, 2020
Abate by
Jan 13, 2021
Penalty
Initial $9,639 · Current $9,639
29 CFR 1910.146(c)(1): The employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces:  In the Spiral Building, at the southside sampling area, employees perform grinding and welding operations inside such as but not limited to 24-inch to 42-inch in diameter steel pipe that is 100-feet in length. This condition exposes employees to the inhalation hazards.
Recent events (3)
  • · F (O) $9639
  • · C (S) $9639
  • · Z (S) $9639

1910.132 D01 I

Serious Gravity 10 1 instance 245 exposed
Issued
Aug 24, 2020
Abate by
Sep 22, 2020
Penalty
Initial $13,494 · Current $7,000 Reduced
29 CFR 1910.132(d)(1)(i):  The employer did not select and have each affected employee use, the types of personal protective equipment that would protect the affected employee(s) from the hazards identified in the hazard assessment:    At the south side sampling area, an employee was observed without a helmet, while using a grinder inside a 24-inch steel pipe. The employer did not ensure that a helmet was being utilized. Employee was exposed to skin burns.
Recent events (2)
  • · I (S) $7000
  • · Z (S) $13494

1910.134 D01 I

Other-than-serious 1 instance 245 exposed
Issued
Aug 24, 2020
Abate by
Sep 22, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.134(d)(1)(i): Selection of appropriate respirators was not based on the respiratory hazard(s) to which the worker was exposed and user factors that affect respirator performance and reliability:  CNC plasma cutter, fume clouds:  Welding/cutting fume clouds existed during the operation of the CNC plasma cutter, this condition exposed employees to acute health effects such as irritations of the mucous membranes e.g. nose and throat.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.134 K05 II

Other-than-serious 1 instance 245 exposed
Issued
Aug 24, 2020
Abate by
Sep 22, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(5)(ii): Retraining was not conducted when inadequacies in the employee's knowledge or use of the respirator indicated that the employee did not retain the necessary training or skill:  At the Southside Sampling area, employees lack the knowledge and training of the chemical hazards associated with welding and cutting steel pipes.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.134 K06

Other-than-serious 2 instances 245 exposed
Issued
Aug 24, 2020
Abate by
Sep 22, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer:  In the Spiral Building, at the South Side Sampling area, employees are provided voluntary use of filtering facepiece  (dust mask) respirators for use while operating machinery and equipment:  a) Employees who stick weld Shielded Metal Arc Welding (SMAW) and Gas Metal Arc (MIG) weld inside of 24 to 42-inch steel pipes. This condition exposed employees to gas inhalation hazards.  b) Employees who operate the CNC Plasma Cutter that automatically cuts including but not limited to 42-inch steel pipes. This practice exposed employees to inhalation hazards.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.252 A02 IV

Deleted Other-than-serious 1 instance 245 exposed
Issued
Aug 24, 2020
Abate by
Sep 22, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.252(a)(2)(iv): The individual responsible for authorizing cutting or welding operations did not designate precautions to be followed in granting authorization to proceed preferably in the form of a written permit:  At the Spiral Building, in the Southside Sampling area, prior to the beginning of welding operations including but not limited to shielded metal arc (stick) and gas metal arc (MIG) welding of steel pipes, the employer did not develop, implement and address precautions to be followed by issuance of hot work permits.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Welspun Tubular, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 344649926.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.