CHICAGO, IL —
OSHA Inspection: CRRC SIFANG AMERICA INCORPORATED
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of CRRC SIFANG AMERICA INCORPORATED in 13535 TORRENCE AVE., CHICAGO, IL 60633 (NAICS 336510). OSHA activity number 344668975.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CRRC SIFANG AMERICA INCORPORATED
- Site address
- 13535 TORRENCE AVE.
- City
- CHICAGO
- State
- IL
- ZIP
- 60633
- Mailing
- 13535 TORRENCE AVE., CHICAGO, IL 60633
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336510
- Employees
- 70
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.30 A01
- Issued
- May 11, 2020
- Abate by
- Jun 5, 2020
- Penalty
- Initial $8,096 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.30(a)(1): (a) Fall hazards. (1) Before any employee is exposed to a fall hazard, the employer did not provide training for each employee who uses personal fall protection systems or who is required to be trained as specified elsewhere in this subpart. Employers must ensure employees are trained in the requirements of this paragraph on or before May 17, 2017. a) On or about March 4, 2020, at the above located workplace, employees in the final assemble/car body and truck assembly marrying area were required to work on an open-sided floor (having pits) which did not have a guardrail system, safety net system, or personal fall arrest system. The employees were thereby exposed to a fall hazard of approximately 5.3 feet. b) On or about March 4, 2020, at the above located workplace, employees in the commissioning shop were required to work on an open-sided floor (having pits) which did not have a guardrail system, safety net system, or personal fall arrest system. The employees were thereby exposed to a fall hazard of approximately 5.3 feet. Employees were not trained in the hazards of working around pits.
Recent events (2)
- — I (S) $4000
- — Z (S) $8096
1910.147 C04 I
- Issued
- May 11, 2020
- Abate by
- Jun 5, 2020
- Penalty
- Initial $9,446 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) On or about February 21, 2020, employees in the assembly shop were exposed to the unexpected energization and release of energy that could cause serious injuries. Employees were required to switch out core grips on an Auxiliary Power Supply unit on a transit system passenger car during assembly and testing, prior to commissioning. The equipment was worked on without being locked out. The employer did not develop and document procedures for the control of potentially hazardous energy for authorized employee use when servicing and/or maintaining this equipment.
Recent events (2)
- — I (S) $0
- — Z (S) $9446
1910.335 A01
- Issued
- May 11, 2020
- Abate by
- Jul 6, 2020
- Penalty
- Initial $9,446 · Current $4,773 Reduced
General-duty citation text
29 CFR 1910.335(a)(1): Employees working in areas where there were potential electrical hazards were not provided with, and/or did not use, electrical protective equipment that was appropriate for the specific parts of the body to be protected and for the work to be performed: a) On or about February 21, 2020, at the above located workplace, employees in the assembly area were required to work with an energized rail car and rail car equipment. At least one high amperage battery was not isolated. An arc flash occurred and knocked an employee to the floor. The employees were not provided and required to use electrical personal protective equipment such as eye and face protection, tested rubber gloves with protective outer leather gloves and arc flash resistant clothing that was appropriate for the specific parts of the body to be protected and for the work to be performed. Employees were exposed to the hazards associated with electrical arc flash. b) On or about late January or early February 2020, at the above located workplace, employees in the assembly area were required install a large, high amperage battery. As they installed the battery, there was an arc flash. The employees performing this work were not provided and required to use electrical personal protective equipment such as eye and face protection, tested rubber gloves with protective outer leather gloves and arc flash resistant clothing that was appropriate for the specific parts of the body to be protected and for the work to be performed. Employees were exposed to the hazards associated with electrical arc flash.
Recent events (2)
- — I (S) $4773
- — Z (S) $9446
1904.4 A
- Issued
- May 11, 2020
- Abate by
- Jun 5, 2020
- Penalty
- Initial $1,350 · Current $0 Reduced
General-duty citation text
29 CFR 1904.4(a): The employer did not record each work-related fatality, injury or illness case that resulted in the general recording criteria on the OSHA Form 300 or equivalent. a) On or about November 12, 2019, a recordable injury occurred when an employee fell in the parking lot. No information related to the injury was not entered on the 2019 calendar year OSHA 300 injury and illness log.
Recent events (2)
- — I (O) $0
- — Z (O) $1350
1910.132 D02
- Issued
- May 11, 2020
- Abate by
- Jun 5, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated, the person certifying that the evaluation has been performed, the date(s) of the hazard assessment, and, which identifies the document as a certification of hazard assessment: a) On or about March 4, 2020, at the above located workplace, employees were exposed to chemical, physical and electrical hazards. The employer did not verify, through a written certification, the identity of the workplace evaluated, the person certifying that the evaluation had been performed, and the date the hazard assessment was done.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Crrc Sifang America Incorporated
View Crrc Sifang America Incorporated's full OSHA safety record →
More inspections in this industry (NAICS 336510)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344668975.