Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CRRC SIFANG AMERICA INCORPORATED

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CRRC SIFANG AMERICA INCORPORATED in 13535 TORRENCE AVE., CHICAGO, IL 60633 (NAICS 336510). OSHA activity number 344668975.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Crrc Sifang America Incorporated — free Get an email when a new federal OSHA severe-injury report for Crrc Sifang America Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
13535 TORRENCE AVE.
City
CHICAGO
State
IL
ZIP
60633
Mailing
13535 TORRENCE AVE., CHICAGO, IL 60633
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336510
Employees
70
Ownership type
A

5 citations on file for this inspection.

1910.30 A01

Serious Gravity 5 2 instances 10 exposed
Issued
May 11, 2020
Abate by
Jun 5, 2020
Penalty
Initial $8,096 · Current $4,000 Reduced
29 CFR 1910.30(a)(1):     (a) Fall hazards. (1) Before any employee is exposed to a fall hazard, the employer did not provide training for each employee who uses personal fall protection systems or who is required to be trained as specified elsewhere in this subpart.  Employers must ensure employees are trained in the requirements of this paragraph on or before May 17, 2017.    a) On or about March 4, 2020, at the above located workplace, employees in the final assemble/car body and truck assembly marrying area were required to work on an open-sided floor (having pits) which did not have a guardrail system, safety net system, or personal fall arrest system. The employees were thereby exposed to a fall hazard of approximately 5.3 feet.        b) On or about March 4, 2020, at the above located workplace, employees in the commissioning shop were required to work on an open-sided floor (having pits) which did not have a guardrail system, safety net system, or personal fall arrest system. The employees were thereby exposed to a fall hazard of approximately 5.3 feet.    Employees were not trained in the hazards of working around pits.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $8096

1910.147 C04 I

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
May 11, 2020
Abate by
Jun 5, 2020
Penalty
Initial $9,446 · Current $0 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:   a) On or about February 21, 2020, employees in the assembly shop were exposed to the unexpected energization and release of energy that could cause serious injuries. Employees were required to switch out core grips on an Auxiliary Power Supply unit on a transit system passenger car during assembly and testing, prior to commissioning. The equipment was worked on without being locked out. The employer did not develop and document procedures for the control of potentially hazardous energy for authorized employee use when servicing and/or maintaining this equipment.
Recent events (2)
  • — I (S) $0
  • — Z (S) $9446

1910.335 A01

Serious Gravity 10 2 instances 2 exposed
Issued
May 11, 2020
Abate by
Jul 6, 2020
Penalty
Initial $9,446 · Current $4,773 Reduced
29 CFR 1910.335(a)(1): Employees working in areas where there were potential electrical hazards were not provided with, and/or did not use, electrical protective equipment that was appropriate for the specific parts of the body to be protected and for the work to be performed:     a) On or about February 21, 2020, at the above located workplace, employees in the assembly area were required to work with an energized rail car and rail car equipment. At least one high amperage battery was not isolated. An arc flash occurred and knocked an employee to the floor. The employees were not provided and required to use electrical personal protective equipment such as eye and face protection, tested rubber gloves with protective outer leather gloves and arc flash resistant clothing that was appropriate for the specific parts of the body to be protected and for the work to be performed. Employees were exposed to the hazards associated with electrical arc flash.    b) On or about late January or early February 2020, at the above located workplace, employees in the assembly area were required install a large, high amperage battery. As they installed the battery, there was an arc flash. The employees performing this work were not provided and required to use electrical personal protective equipment such as eye and face protection, tested rubber gloves with protective outer leather gloves and arc flash resistant clothing that was appropriate for the specific parts of the body to be protected and for the work to be performed. Employees were exposed to the hazards associated with electrical arc flash.
Recent events (2)
  • — I (S) $4773
  • — Z (S) $9446

1904.4 A

Other-than-serious 1 instance 1 exposed
Issued
May 11, 2020
Abate by
Jun 5, 2020
Penalty
Initial $1,350 · Current $0 Reduced
29 CFR 1904.4(a): The employer did not record each work-related fatality, injury or illness case that resulted in the general recording criteria on the OSHA Form 300 or equivalent.       a) On or about November 12, 2019, a recordable injury occurred when an employee fell in the parking lot. No information related to the injury was not entered on the 2019 calendar year OSHA 300 injury and illness log.
Recent events (2)
  • — I (O) $0
  • — Z (O) $1350

1910.132 D02

Deleted Other-than-serious 1 instance 20 exposed
Issued
May 11, 2020
Abate by
Jun 5, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated, the person certifying that the evaluation has been performed, the date(s) of the hazard assessment, and, which identifies the document as a certification of hazard assessment:   a) On or about March 4, 2020, at the above located workplace, employees were exposed to chemical, physical and electrical hazards. The employer did not verify, through a written certification, the identity of the workplace evaluated, the person certifying that the evaluation had been performed, and the date the hazard assessment was done.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Crrc Sifang America Incorporated's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344668975.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.