JAMESTOWN, PA —
OSHA Inspection: COMBINED SYSTEMS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of COMBINED SYSTEMS, INC. in 388 KINSMAN ROAD, JAMESTOWN, PA 16134 (NAICS 332993). OSHA activity number 344672936.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COMBINED SYSTEMS, INC.
- Site address
- 388 KINSMAN ROAD
- City
- JAMESTOWN
- State
- PA
- ZIP
- 16134
- Mailing
- 388 KINSMAN ROAD, JAMESTOWN, PA 16134
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332993
- Employees
- 235
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.212 A01
- Issued
- Aug 12, 2020
- Abate by
- Sep 8, 2020
- Penalty
- Initial $5,899 · Current $4,500 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: A.) Combined Systems, Inc., 388 Kinsman Rd, Jamestown, PA 16134, Building D-2, on or about February 25, 2020 and times prior thereto: Employee operates an Enco Variable Speed Mini Lathe to perform work operations including, but not limited to, cutting down brass tubes. The lathe was not equipped with a chuck guard.
Recent events (2)
- — I (S) $4500
- — Z (S) $5899
1910.212 A03 II
- Issued
- Aug 12, 2020
- Abate by
- Sep 8, 2020
- Penalty
- Initial $5,899 · Current $4,500 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): A.) Combined Systems, Inc., 388 Kinsman Rd, Jamestown, PA 16134, Building D-2, on or about February 25, 2020 and times prior thereto: Employees operate a dual palm button Atlas air press (pancake press) for work operations that include, but are not limited to, consolidating powder into brass delay tubes. The pancake press is actuated by a two-hand trip device and potentially exposes employee to an amputation/crush hazards due to the delay and slow speed of the machine cycle.
Recent events (2)
- — I (S) $4500
- — Z (S) $5899
1910.305 G01 IV
- Issued
- Aug 12, 2020
- Abate by
- Sep 8, 2020
- Penalty
- Initial $4,424 · Current $700 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv): Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv): A.) Combined Systems, Inc., 388 Kinsman Rd, Jamestown, PA 16134, Building D-2, on or about February 25, 2020 and times prior thereto: A flexible cord was plugged into an electrical receptacle, running down the wall, and across the floor to a second flexible cord which was powering an electrical knockout box and subsequently powered equipment including, but not limited to, a Uline scale on the table. The use of the flexible cords were prohibited in that they were used in lieu of permanent wiring of the structure. B.) Combined Systems, Inc., 388 Kinsman Rd, Jamestown, PA 16134, Building D-2, on or about February 25, 2020 and times prior thereto: A flexible cord was ran to a metal knockout box that was on the floor of the building. The metal knockout box powered equipment including, but not limited to, a Fisher Scientific IsoTemp Incubator (M/N: 550D, S/N: 60500062). The use of the flexible cords were prohibited in that they were used in lieu of permanent wiring of the structure.
Recent events (2)
- — I (S) $700
- — Z (S) $4424
1910.303 B02
- Issued
- Aug 12, 2020
- Abate by
- Sep 8, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: A.) Combined Systems, Inc., 388 Kinsman Rd, Jamestown, PA 16134, Building D-2, on or about February 25, 2020 and times prior thereto: A flexible cord was ran to a metal knockout box that was on the floor of the building. The metal knockout box powered equipment including, but not limited to, a Fisher Scientific IsoTemp Incubator (M/N: 550D, S/N: 60500062). The metal knockout box is not designed for portable applications as a cord cap at the end of a flexible cord, and is required to be mounted.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Combined Systems, INC.
View Combined Systems, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332993)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344672936.