Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: COMBINED SYSTEMS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of COMBINED SYSTEMS, INC. in 388 KINSMAN ROAD, JAMESTOWN, PA 16134 (NAICS 332993). OSHA activity number 344672936.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Combined Systems, INC. — free Get an email when a new federal OSHA severe-injury report for Combined Systems, INC. is published. One employer, no account, unsubscribe in one click.
Site address
388 KINSMAN ROAD
City
JAMESTOWN
State
PA
ZIP
16134
Mailing
388 KINSMAN ROAD, JAMESTOWN, PA 16134
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332993
Employees
235
Ownership type
A

4 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 12, 2020
Abate by
Sep 8, 2020
Penalty
Initial $5,899 · Current $4,500 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    A.)  Combined Systems, Inc., 388 Kinsman Rd, Jamestown, PA 16134, Building D-2, on or about February 25, 2020 and times prior thereto:  Employee operates an Enco Variable Speed Mini Lathe to perform work operations including, but not limited to, cutting down brass tubes.  The lathe was not equipped with a chuck guard.
Recent events (2)
  • — I (S) $4500
  • — Z (S) $5899

1910.212 A03 II

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 12, 2020
Abate by
Sep 8, 2020
Penalty
Initial $5,899 · Current $4,500 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    A.)  Combined Systems, Inc., 388 Kinsman Rd, Jamestown, PA 16134, Building D-2, on or about February 25, 2020 and times prior thereto:  Employees operate a dual palm button Atlas air press (pancake press) for work operations that include, but are not limited to, consolidating powder into brass delay tubes.  The pancake press is actuated by a two-hand trip device and potentially exposes employee to an amputation/crush hazards due to the delay and slow speed of the machine cycle.
Recent events (2)
  • — I (S) $4500
  • — Z (S) $5899

1910.305 G01 IV

Serious Gravity 1 2 instances 1 exposed
Issued
Aug 12, 2020
Abate by
Sep 8, 2020
Penalty
Initial $4,424 · Current $700 Reduced
29 CFR 1910.305(g)(1)(iv): Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv):    A.)  Combined Systems, Inc., 388 Kinsman Rd, Jamestown, PA 16134, Building D-2, on or about February 25, 2020 and times prior thereto:  A flexible cord was plugged into an electrical receptacle, running down the wall, and across the floor to a second flexible cord which was powering an electrical knockout box and subsequently powered equipment including, but not limited to, a Uline scale on the table.  The use of the flexible cords were prohibited in that they were used in lieu of permanent wiring of the structure.     B.)  Combined Systems, Inc., 388 Kinsman Rd, Jamestown, PA 16134, Building D-2, on or about February 25, 2020 and times prior thereto:  A flexible cord was ran to a metal knockout box that was on the floor of the building.  The metal knockout box powered equipment including, but not limited to, a Fisher Scientific IsoTemp Incubator (M/N:  550D, S/N:  60500062).  The use of the flexible cords were prohibited in that they were used in lieu of permanent wiring of the structure.
Recent events (2)
  • — I (S) $700
  • — Z (S) $4424

1910.303 B02

Serious Gravity 1 1 instance 1 exposed
Issued
Aug 12, 2020
Abate by
Sep 8, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  A.)  Combined Systems, Inc., 388 Kinsman Rd, Jamestown, PA 16134, Building D-2, on or about February 25, 2020 and times prior thereto:  A flexible cord was ran to a metal knockout box that was on the floor of the building.  The metal knockout box powered equipment including, but not limited to, a Fisher Scientific IsoTemp Incubator (M/N:  550D, S/N:  60500062).  The metal knockout box is not designed for portable applications as a cord cap at the end of a flexible cord, and is required to be mounted.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Combined Systems, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344672936.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.