MENOMONEE FALLS, WI —
OSHA Inspection: UNIVERSAL METRICS, LLC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of UNIVERSAL METRICS, LLC in N93W14475 WHITTAKER WAY, MENOMONEE FALLS, WI 53051 (NAICS 339112). OSHA activity number 344680343.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- UNIVERSAL METRICS, LLC
- Site address
- N93W14475 WHITTAKER WAY
- City
- MENOMONEE FALLS
- State
- WI
- ZIP
- 53051
- Mailing
- N93W14475 WHITTAKER WAY, MENOMONEE FALLS, WI 53051
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 339112
- Employees
- 70
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.134 E01
- Issued
- Jul 23, 2020
- Abate by
- Aug 11, 2020
- Penalty
- Initial $3,441 · Current $3,441
9135F104
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (a) On or about March 6, 2020, a welder(s) used elastomeric respirator voluntarily while performing welding work without a medical evaluation to determine the employee's ability to use a respirator. (b) On or about March 11, 2020, a welder(s) used elastomeric respirator voluntarily while performing welding work without a medical evaluation to determine the employee's ability to use a respirator.
Recent events (2)
- — P (S) $3441
- — Z (S) $3441
1910.134 F01
- Issued
- Jul 23, 2020
- Abate by
- Aug 11, 2020
- Penalty
- Initial $0 · Current $0
9135F104
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): (a) On or about March 6, 2020, a welder(s) used 3M elastomeric half face respirator voluntarily while performing welding work without a fit test. (b) On or about March 11, 2020, a welder(s) used 3M elastomeric respirator voluntarily while performing welding work without a fit test.
Recent events (2)
- — P (S) $0
- — Z (S) $0
1910.1000 A02
- Issued
- Jul 23, 2020
- Abate by
- Oct 26, 2020
- Penalty
- Initial $6,882 · Current $6,882
15209135F104
General-duty citation text
29 CFR 1910.1000(a)(2): Employee were exposed to an airborne concentration of Total Particulate dust containing Iron Oxide listed in Table Z-1 in excess of the 8 hour Time Weighted Average concentration of 15 mg per cubic meter of air for the Total Particulates and the 8 hour Time Weighted Average concentration of 10 mg per cubic meter of air for Total Iron Oxide. (a) On or about March 11, 2020, the welder in welding booth #1 next to the robotic welder was exposed to particulates not otherwise regulated Total Particulate dust at an 8-hour time weighted average of 35.8 milligrams per cubic meter of air, approximately 2.39 times the limit of 15 milligrams per cubic meter of air. **This limit is established to prevent upper respiratory tract irritation and pneumoconiosis. The sample was collected during a 360 minute sampling period, and exposure calculations include a zero increment for the 120 minutes not sampled. (b) On or about March 11, 2020, the welder in welding booth #1 next to the robotic welder was exposed to Iron Oxide dust and fumes at an 8-hour time weighted average of 27.2 milligrams per cubic meter of air, approximately 2.72 times the limit of 10 milligrams per cubic meter of air. **This limit is established to prevent upper respiratory tract irritation and siderosis. The sample was collected on during a 360 minute sampling period, and exposure calculations include a zero increment for the 120 minutes not sampled.
Recent events (2)
- — P (S) $6882
- — Z (S) $6882
1910.1000 E
- Issued
- Jul 23, 2020
- Abate by
- Oct 26, 2020
- Penalty
- Initial $0 · Current $0
15209135F104
General-duty citation text
29 CFR 1910.1000(e): Feasible administrative or engineering controls were not determined and implemented to achieve compliance with the limits prescribed in 29 CFR 1910.1000(a) through (d): (a) On or about March 11, 2020, the welder in welding booth #1 next to the robotic welder was exposed to particulates not otherwise regulated Total Particulate dust at an 8-hour time weighted average of 35.8 milligrams per cubic meter of air, approximately 2.39 times the limit of 15 milligrams per cubic meter of air. The sample was collected during a 360 minute sampling period, and exposure calculations include a zero increment for the 120 minutes not sampled. The existing control measures, including administrative and engineering controls, were not adequate to limit the exposure of employees to mercury to or below the PEL. (b) On or about March 11, 2020, the welder in welding booth #1 next to the robotic welder was exposed to Iron Oxide dust and fumes at an 8-hour time weighted average of 27.2 milligrams per cubic meter of air, approximately 2.72 times the limit of 10 milligrams per cubic meter of air. The sample was collected on during a 360 minute sampling period, and exposure calculations include a zero increment for the 120 minutes not sampled. The existing control measures, including administrative and engineering controls, were not adequate to limit the exposure of employees to mercury to or below the PEL.
Recent events (2)
- — P (S) $0
- — Z (S) $0
1910.1200 F06 II
- Issued
- Jul 23, 2020
- Penalty
- Initial $3,441 · Current $3,441
General-duty citation text
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical (a) On or about March 6, 2020, at the weld stations, employees used spray bottles containing anti-spatter or soap solution. Spray bottles were not labeled with content identity, and pictograms or warnings of hazards.
Recent events (1)
- — Z (S) $3441
1910.303 G01
- Issued
- Jul 23, 2020
- Abate by
- Aug 11, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1): Space about electric equipment. Sufficient access and working space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment. (a) On or about March 11, 2020, access to a wall mounted electrical panel box for lighting and other equipment was blocked by long metal pieces on the floor and saw horses. These materials also blocked easy access to on/off switches for ceiling mounted HVAC units.
Recent events (1)
- — Z (O) $0
More inspections at Universal Metrics, LLC
View Universal Metrics, LLC's full OSHA safety record →
More inspections in this industry (NAICS 339112)
More inspections in WI