COLORADO SPRINGS, CO —
OSHA Inspection: CEA MEDICAL MANUFACTURING, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of CEA MEDICAL MANUFACTURING, INC. in 1735 MERCHANTS CT, COLORADO SPRINGS, CO 80916 (NAICS 339112). OSHA activity number 344688288.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CEA MEDICAL MANUFACTURING, INC.
- Site address
- 1735 MERCHANTS CT
- City
- COLORADO SPRINGS
- State
- CO
- ZIP
- 80916
- Mailing
- 1735 MERCHANTS CT, COLORADO SPRINGS, CO 80916
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 339112
- Employees
- 113
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.1025 D02
- Issued
- Apr 23, 2020
- Abate by
- Jun 15, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1025(d)(2): An initial determination was not made to determine if any employee may be exposed to lead at or above the action level: a) On or about March 11, 2020, and at times prior, the employer did conduct initial monitoring to ensure employees performing lead soldering operations were not exposed to hazardous levels of airborne lead. Abatement Note: Abatement certification is required for this item (See Certification of Corrective Action Worksheet).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1048 D01 I
- Issued
- Apr 23, 2020
- Penalty
- Initial $0 · Current $0
1290
General-duty citation text
29 CFR 1910.1048(d)(1)(i): Employees of a workplace covered by this standard were not monitored to determine their exposure to formaldehyde: a) On or about March 11, 2020, and at times prior, the employer did not ensure that employees conducting injection molding operations were not exposed to hazardous levels of formaldehyde. Abatement note: Abatement certification and documentation are required for this item (See Certification of Corrective Action Worksheet).
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at CEA Medical Manufacturing, INC.
View CEA Medical Manufacturing, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 339112)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344688288.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.