Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: THERMACOR PROCESS INC.

Follow-up inspection · Health discipline

On , OSHA opened a follow-up health inspection of THERMACOR PROCESS INC. in 1670 E. HICKS FIELD ROAD, SAGINAW, TX 76179 (NAICS 331210). OSHA activity number 344696828.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Thermacor Process INC. for free Get an email when a new federal OSHA severe-injury report for Thermacor Process INC. is published. One employer, no account, unsubscribe in one click.
Site address
1670 E. HICKS FIELD ROAD
City
SAGINAW
State
TX
ZIP
76179
Mailing
1670 E. HICKS FIELD ROAD, SAGINAW, TX 76179
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331210
Employees
120
Ownership type
Private (A)

2 citations on file for this inspection.

1910.253 B02 IV

Serious Gravity 5 6 instances 120 exposed
Issued
Mar 20, 2020
Abate by
Apr 17, 2020
Penalty
Initial $6,940 · Current $4,164 Reduced
29 CFR 1910. 253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use:        On or about March 12, 2020 and at times prior thereto, at a workplace located at 1670 E. Hicks Field Road, Saginaw, Texas; oxygen, argon and compressed gas cylinder caps were not in place when the cylinders were not in use.
Recent events (2)
  • · I (S) $4164
  • · Z (S) $6940

1910.303 E01 II

Serious Gravity 5 5 instances 6 exposed
Issued
Mar 20, 2020
Abate by
Apr 17, 2020
Penalty
Initial $6,940 · Current $4,164 Reduced
29 CFR 1910. 303(e)(1)(ii): Markings were not provided for voltage, current, wattage, and other ratings as necessary:    On or about March 12, 2020 and at times prior thereto, at a workplace located at 1670 E. Hicks Field Road, Saginaw, Texas; the employer had electrical panel boxes that were energized with no marked voltage ratings.
Recent events (2)
  • · I (S) $4164
  • · Z (S) $6940

View Thermacor Process INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 344696828.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.