OSHA Inspection: SUNBURN CONSTRUCTION, LLC

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of SUNBURN CONSTRUCTION, LLC in 504 KOPP ROAD, WAUNAKEE, WI 53597 (NAICS 238210). OSHA activity number 344701263.

Watch Sunburn Construction, LLC — free Get an email when a new federal OSHA severe-injury report for Sunburn Construction, LLC is published. One employer, no account, unsubscribe in one click.
Site address
504 KOPP ROAD
City
WAUNAKEE
State
WI
ZIP
53597
Mailing
6720 FAIRHAVEN ROAD, UNIT 3, MADISON, WI 53719
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
4
Ownership type
A

4 citations on file for this inspection.

1926.20 B01

Other-than-serious 1 instance 4 exposed
Issued
Sep 15, 2020
Abate by
Oct 6, 2020
Penalty
Initial $5,399 · Current $4,589 Reduced
29 CFR 1926.20(b)(1): The employer did not initiate and maintain accident prevention programs as necessary to comply with this part:    On or about March 17, 2020, and times prior, the employer did not initiate and maintain safety and health programs.
Recent events (2)
  • — I (O) $4589
  • — Z (S) $5399

1926.21 B02

Other-than-serious 1 instance 4 exposed
Issued
Sep 15, 2020
Abate by
Oct 6, 2020
Penalty
Initial $0 · Current $0
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury:    On or about March 17, 2020, and times prior, the employer did not instruct each employee on the recognition and avoidance of unsafe conditions and the regulations applicable to the work environment.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1926.416 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 15, 2020
Abate by
Sep 23, 2020
Penalty
Initial $13,494 · Current $11,470 Reduced
29 CFR 1926.416(a)(1): An employee was permitted to work in proximity to an electric power circuit that the employee could contact in the course of work and was not protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means:    On or about March 17, 2020 an employee was permitted to operator an aerial lift (model JLG T500J) in close proximity to an unguarded powerline that was not de-energized and grounded or effectively guarded.
Recent events (2)
  • — I (S) $11470
  • — Z (S) $13494

1926.453 B02 V

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 15, 2020
Abate by
Sep 29, 2020
Penalty
Initial $13,494 · Current $11,470 Reduced
29 CFR 1926.453(b)(2)(v): A safety harness with lanyard attached to the boom or basket was not worn by employee(s) working from an aerial lift:    On or about March 17, 2020 an employee working from a aerial lift (model JLG T500J) was doing so without a harness and lanyard attached to the boom or basket.
Recent events (2)