SOCIAL CIRCLE, GA —
OSHA Inspection: MASTERACK, LLC
Federal Agency inspection · Health discipline
At a glance
On , OSHA opened a federal Agency health inspection of MASTERACK, LLC in 1 WATERS DRIVE 1670 ANNIE P HENDERSON ROAD, SOCIAL CIRCLE, GA 30025 (NAICS 336390). OSHA activity number 344789730.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MASTERACK, LLC
- Site address
- 1 WATERS DRIVE 1670 ANNIE P HENDERSON ROAD
- City
- SOCIAL CIRCLE
- State
- GA
- ZIP
- 30025
- Mailing
- 2400 MELLON COURT, DECATUR, GA 30035
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336390
- Employees
- 63
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.134 C01
- Issued
- Nov 30, 2020
- Abate by
- Dec 17, 2020
- Penalty
- Initial $12,145 · Current $12,145
General-duty citation text
29 CFR 1910.134(c)(1):The respiratory protection program was not updated as necessary to reflect those changes in workplace conditions that affected respirator use: On or about 06/05/2020, at the Masterack, LLC, the employer's written respiratory protection program did not include all necessary information, including but not limited to, the workplace respiratory selection used in the facility.
Recent events (1)
- — Z (S) $12145
1910.134 E01
- Issued
- Nov 30, 2020
- Abate by
- Dec 17, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1):The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: On or about 06/05/2020, at the Masterack, LLC, the employer did not ensure employees required to use a Supplied Air Respirator while powder coating metal vehicle parts were medically evaluated.
Recent events (1)
- — Z (S) $0
More inspections at Masterack, LLC
View Masterack, LLC's full OSHA safety record →
More inspections in this industry (NAICS 336390)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344789730.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.