BYRON, GA —
OSHA Inspection: PYROTECHNIC SPECIALTIES, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of PYROTECHNIC SPECIALTIES, INC. in 1661 JUNIPER CREEK ROAD, BYRON, GA 31008 (NAICS 325920). OSHA activity number 344796271.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PYROTECHNIC SPECIALTIES, INC.
- Site address
- 1661 JUNIPER CREEK ROAD
- City
- BYRON
- State
- GA
- ZIP
- 31008
- Mailing
- 1661 JUNIPER CREEK ROAD, BYRON, GA 31008
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325920
- Employees
- 110
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.119 D03 II
- Issued
- Oct 2, 2020
- Abate by
- Nov 20, 2020
- Penalty
- Initial $13,359 · Current $8,015 Reduced
General-duty citation text
29 CFR 1910.119(d)(3)(ii): The employer did not document that equipment complies with recognized and generally accepted good engineering practices. On or about 6/17/20, at the Byron facility, the employer did not assure new tooling used on presses had been X-rayed prior to putting the tooling in service, per the procedure established at the facility. Tooling used on press 8 jammed resulting in a deflagration.
Recent events (2)
- — I (S) $8015.4
- — Z (S) $13359
1910.147 C06 I B
- Issued
- Oct 2, 2020
- Abate by
- Nov 20, 2020
- Penalty
- Initial $13,359 · Current $8,015 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i)(B): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed. On or about 6/19/20, at the Byron facility, the employer did not ensure a periodic inspection of the Lockout program was conducted to ensure deficiencies were corrected. Deficiencies included: a - Employees who were servicing and maintaining presses at the site did not know or understand the magnitude of energy for the equipment they were charged with maintaining. Specific procedures did not indicate what the magnitudes of energy were and the employees interviewed indicated they did not know. b - Procedures did not indicate what piece of equipment the procedure was for and instead addressed all presses despite the fact the presses are on different disconnects. c - A specific statement of the intended use of the procedure. d - Specific requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures. e - The certification did not identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection.
Recent events (2)
- — I (S) $8015.4
- — Z (S) $13359
1910.147 C07 I A
- Issued
- Oct 2, 2020
- Abate by
- Nov 20, 2020
- Penalty
- Initial $13,359 · Current $8,015 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation. On 6/19/20, at the Byron facility, the employer did not train press operators who were providing service and maintenance to presses as Authorized employees.
Recent events (2)
- — I (S) $8015.4
- — Z (S) $13359
More inspections at Pyrotechnic Specialties, INC.
View Pyrotechnic Specialties, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 325920)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344796271.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.