Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PYROTECHNIC SPECIALTIES, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PYROTECHNIC SPECIALTIES, INC. in 1661 JUNIPER CREEK ROAD, BYRON, GA 31008 (NAICS 325920). OSHA activity number 344796271.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pyrotechnic Specialties, INC. — free Get an email when a new federal OSHA severe-injury report for Pyrotechnic Specialties, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1661 JUNIPER CREEK ROAD
City
BYRON
State
GA
ZIP
31008
Mailing
1661 JUNIPER CREEK ROAD, BYRON, GA 31008
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325920
Employees
110
Ownership type
A

3 citations on file for this inspection.

1910.119 D03 II

Serious Gravity 10 1 instance 20 exposed
Issued
Oct 2, 2020
Abate by
Nov 20, 2020
Penalty
Initial $13,359 · Current $8,015 Reduced
29 CFR 1910.119(d)(3)(ii): The employer did not document that equipment complies with recognized and generally accepted good engineering practices.  On or about 6/17/20, at the Byron facility, the employer did not assure new tooling used on presses had been X-rayed prior to putting the tooling in service, per the procedure established at the facility. Tooling used on press 8 jammed resulting in a deflagration.
Recent events (2)
  • — I (S) $8015.4
  • — Z (S) $13359

1910.147 C06 I B

Serious Gravity 10 1 instance 20 exposed
Issued
Oct 2, 2020
Abate by
Nov 20, 2020
Penalty
Initial $13,359 · Current $8,015 Reduced
29 CFR 1910.147(c)(6)(i)(B): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.  On or about 6/19/20, at the Byron facility, the employer did not ensure a periodic inspection of the Lockout program was conducted to ensure deficiencies were corrected. Deficiencies included:   a - Employees who were servicing and maintaining presses at the site did not know or understand the magnitude of energy for the equipment they were charged with maintaining. Specific procedures did not indicate what the magnitudes of energy were and the employees interviewed indicated they did not know.    b - Procedures did not indicate what piece of equipment the procedure was for and instead addressed all presses despite the fact the presses are on different disconnects.    c - A specific statement of the intended use of the procedure.   d - Specific requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures.  e - The certification did not identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection.
Recent events (2)
  • — I (S) $8015.4
  • — Z (S) $13359

1910.147 C07 I A

Serious Gravity 10 1 instance 10 exposed
Issued
Oct 2, 2020
Abate by
Nov 20, 2020
Penalty
Initial $13,359 · Current $8,015 Reduced
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation.  On 6/19/20, at the Byron facility, the employer did not train press operators who were providing service and maintenance to presses as Authorized employees.
Recent events (2)
  • — I (S) $8015.4
  • — Z (S) $13359

View Pyrotechnic Specialties, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344796271.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.