BYRON, GA —
OSHA Inspection: PYROTECHNIC SPECIALTIES, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of PYROTECHNIC SPECIALTIES, INC. in 1661 JUNIPER CREEK ROAD, BYRON, GA 31008 (NAICS 325920). OSHA activity number 345731236.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PYROTECHNIC SPECIALTIES, INC.
- Site address
- 1661 JUNIPER CREEK ROAD
- City
- BYRON
- State
- GA
- ZIP
- 31008
- Mailing
- 1661 JUNIPER CREEK ROAD, BYRON, GA 31008
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325920
- Employees
- 110
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.119 F01
- Issued
- Jun 24, 2022
- Abate by
- Aug 4, 2022
- Penalty
- Initial $10,256 · Current $7,692 Reduced
General-duty citation text
29 CFR 1910.119(f)(1):The employer did not develop and implement written operating procedures that provided clear instructions for safely conducting activities involved in each covered process consistent with the process safety information and that addressed at least the following elements. 29 CFR 1910.119(f)(1)(ii): Operating limits. 29 CFR 1910.119(f)(1)(iii)(A): Properties of, and hazards presented by, the chemicals used in the process. 29 CFR 1910.119(f)(1)(iii)(B): Precautions necessary to prevent exposure, including engineering controls, administrative controls, and personal protective equipment. a) Plant, Test Tunnel for Light Intensity area; on or about January 13, 2022, and at times prior to, employees were exposed to thermal radiation skin burns, in that the employer did not develop and implement an operating procedure for testing/demonstration of the energy content of pyrotechnic materials that addressed at least the maximum safe amounts, the hazardous properties, and the controls on electrical matches to prevent accidental ignition. b) Plant, Test Tunnel for Light Intensity area; on or about January 13, 2022, and at times prior to, employees were exposed to thermal radiation skin burns, in that the employer did not ensure that the light intensity measurement procedure PSI-P-0886 addressed controls on electrical matches to prevent accidental ignition of the samples.
Recent events (2)
- — I (S) $7692
- — Z (S) $10256
1910.147 C04 I
- Issued
- Jun 24, 2022
- Abate by
- Aug 4, 2022
- Penalty
- Initial $10,256 · Current $7,692 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i):Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Plant, Test Tunnel for Light Intensity area; on or about January 13, 2022 and at times prior to, employees conducting tests/demonstrations on high energy materials were exposed to thermal radiation burn and overpressure hazards, in that the employer did not develop, implement, and utilize lockout/tagout procedures to control the electric power supply to the electric matches to prevent accidental ignition. b) Plant, Test Tunnel for Light Intensity area; on or about January 13, 2022 and at times prior to, employees conducting light intensity tests on candle samples were exposed to thermal radiation burns, in that the employer did not develop, implement, and utilize lockout/tagout procedures to control the electric power supply to the electric matches to prevent accidental ignition.
Recent events (2)
- — I (S) $7692
- — Z (S) $10256
More inspections at Pyrotechnic Specialties, INC.
View Pyrotechnic Specialties, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 325920)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345731236.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.