ATLANTA, GA —
OSHA Inspection: AMWARE FULFILLMENT OF GEORGIA, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of AMWARE FULFILLMENT OF GEORGIA, LLC in 650 SELIG DR. SW UNIT B, ATLANTA, GA 30336 (NAICS 493110). OSHA activity number 344861794.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AMWARE FULFILLMENT OF GEORGIA, LLC
- Site address
- 650 SELIG DR. SW UNIT B
- City
- ATLANTA
- State
- GA
- ZIP
- 30336
- Mailing
- 650 SELIG DR. SW UNIT B, ATLANTA, GA 30336
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493110
- Employees
- 23
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.151 C
- Issued
- Jan 14, 2021
- Abate by
- Mar 4, 2021
- Penalty
- Initial $8,482 · Current $5,089 Reduced
General-duty citation text
29 CFR 1910.151(c):Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: a) Side A Warehouse Area: On or about July 31, 2020, quick drenching or flushing units were not provided for and/or to employees who work with corrosive chemicals. Chemicals used at the facility include but are not limited to, Morpholine (pH=11.0), Dynasylan 1189 (pH=10.9), Methane Sulphonic Acid (pH<0.5), and Lauryl Glucoside (pH=12.5).
Recent events (2)
- — I (S) $5089.2
- — Z (S) $8482
1910.178 M02
- Issued
- Jan 14, 2021
- Abate by
- Jan 27, 2021
- Penalty
- Initial $13,494 · Current $8,096 Reduced
General-duty citation text
29 CFR 1910.178(m)(2):Employee(s) stood under or passed under the elevated portion of a powered industrial truck(s) a) Side B Warehouse Area: On or about July 23, 2020, the employer exposed employees in the dock and/or warehouse areas to struck-by hazards in that employees were required to work under the uplifted forks of the the company's forklift trucks, including but not limited to, Toyota Forklift Truck (Model# 8FGCU25 S/N 66066) and Hyster Forklift Truck (Model# S50FT S/N H187V14942U).
Recent events (2)
- — I (O) $8096.4
- — Z (S) $13494
1910.1200 H01
- Issued
- Jan 14, 2021
- Abate by
- Jan 27, 2021
- Penalty
- Initial $6,361 · Current $0 Reduced
General-duty citation text
29 CFR 1910.1200(h)(1):Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a) Side A and Side B Warehouse Areas: On or before July 31, 2020, employees were not trained on the hazardous chemicals utilized in the workplace. Chemicals used at the site include; but are not limited to, Morpholine, Dynasylan 1189, and Lauryl Glucoside.
Recent events (2)
- — I (S) $0
- — Z (S) $6361
1910.1200 H03 IV
- Issued
- Jan 14, 2021
- Abate by
- Jan 27, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(3)(iv): The details of the hazard communication program developed by the employer, did not include an explanation of the labels received on shipped containers and the workplace labeling system used by their employer; the safety data sheet, including the order of information and how employee could obtain and use the appropriate hazard information: a) Side A and Side B Warehouse Areas: On or before July 31, 2020, the employer failed to provide training or information to employees working with hazardous chemicals on the details of outline in the new hazard communication standard which encompass the Global Harmonization System (GHS).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.37 A03
- Issued
- Jan 14, 2021
- Penalty
- Initial $42,411 · Current $13,653 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit routes were not kept free and unobstructed: a) Side A Dock Area: On or about July 31, 2020, employees who worked in A Side warehouse and dock area were potentially exposed to fire hazards in that, a chain-linked fence blocked an exit door. b) Side B Dock Area: On or about July 31, 2020, employees who worked in B Side warehouse and dock area were potentially exposed to fire hazards in that, a chain-linked fence blocked an exit door. Amware Fulfillment of Georgia, LLC DBA Amware Fulfillment was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.37(a)(3), which was contained in OSHA inspection number 1449013, citation number 1, item number 2 and was affirmed as a final order on 05/26/2020 with respect to a workplace located at 650 Selig Drive SW unit B, Atlanta, GA 30336.
Recent events (2)
- — I (S) $13653
- — Z (R) $42411
1910.134 C01
- Issued
- Jan 14, 2021
- Abate by
- Feb 10, 2021
- Penalty
- Initial $53,015 · Current $0 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a) Side A Warehouse Area: On or about July 31, 2020, the employer failed to establish and implement an adequate written respiratory protection program to protect employees from acute respiratory inhalation problems. Chemicals used at the site include, but not limited to; Styrene, Desmodur H (an Aliphatic Isocyanate), Desmodur W (an Aliphatic Diisocyanate), and Desmodur I (an Cycloaliphatic Diisocyanate). The employees were required to wear the 3M 60922 full-face piece masks for chemical spills and/or clean up. Amware Fulfillment of Georgia, LLC DBA Amware Fulfillment was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.134(c)(1), which was contained in OSHA inspection number 1449013, citation number 2, item number 1 and was affirmed as a final order on 05/26/2020 with respect to a workplace located at 650 Selig Drive SW unit B, Atlanta, GA 30336.
Recent events (2)
- — I (R) $0
- — Z (R) $53015
1910.157 C01
- Issued
- Jan 14, 2021
- Abate by
- Jan 27, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(1):Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: a) Side B Dock Area: On or about July 31, 2020, employees were exposed to fire hazards because a portable fire extinguisher was placed on floor and not mounted as required.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Amware Fulfillment of Georgia, LLC