Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: IKO INDUSTRIES LTD.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of IKO INDUSTRIES LTD. in 120 HAY ROAD, WILMINGTON, DE 19809 (NAICS 324122). OSHA activity number 344900063.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch IKO Industries LTD. — free Get an email when a new federal OSHA severe-injury report for IKO Industries LTD. is published. One employer, no account, unsubscribe in one click.
Establishment
IKO INDUSTRIES LTD.
Site address
120 HAY ROAD
City
WILMINGTON
State
DE
ZIP
19809
Mailing
120 HAY ROAD, WILMINGTON, DE 19809
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
324122
Employees
52
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 II

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Feb 24, 2021
Abate by
Mar 22, 2021
Penalty
Initial $13,653 · Current $0 Reduced
29 CFR  1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this section:   a) 120 Hay Road, Wilmington, DE 19809: North End of FPL - On or about August 31, 2020, the employer failed to ensure that the energy control plan identified specific steps to be followed in order to control hazardous energy for employees who serviced or performed maintenance on energized equipment within the production facility.  Note: The procedure must contain information which authorized employees must know to safely control hazardous energy. Over generalization can result in a document which has little or no utility to the employee who must follow procedure. However, while the procedure is required to be written in detail this does not mean that a separate procedure must be written for each and every machine or piece equipment. Similar machines and/or equipment (those using the same type and magnitude energy) that has the same or similar types of control can be covered with a single procedure.
Recent events (2)
  • — I (S) $0
  • — Z (S) $13653

1910.147 C06 I

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Feb 24, 2021
Abate by
Mar 22, 2021
Penalty
Initial $13,653 · Current $0 Reduced
29 CFR  1910.147(c)(6)(i):The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed:  a) 120 Hays Road Wilmington, DE: North End of FPL - On or about August 31, 2020, the employer failed to ensure an inspection of the developed written energy control procedure was conducted at least annually.  Abatement Note:  1. Where lockout should be used to energy control, the periodic inspection shall include a review, between the inspector and each authorized employee of the that employee's responsibilities under the energy control procedure being inspected. 1910.147(c) (6)(i)(D)  2. Where tagout should be used for energy control. the periodic inspection shall include a review, between the inspections and each authorized and affected employee, of that employee's responsibilities under the energy control procedure being inspected, and the elements set forth in paragraph (c) (7) (ii) of this section. 1910.147 (c) (6) (ii)
Recent events (2)
  • — I (S) $0
  • — Z (S) $13653

1910.219 F03

Other-than-serious Gravity 10 1 instance 1 exposed
Issued
Feb 24, 2021
Penalty
Initial $13,653 · Current $13,653
29 CFR  1910.219(f)(3): Sprocket wheels and chains which were seven (7) feet or less above floors or platforms were not enclosed:  a) 120 Hays Street Wilmington, DE: North end of FPL - On or about August 31, 2020, the employer failed to fully enclose the finish product line drive mechanism chains and sprockets, exposing employees who attempted to conduct cleaning and jam clearing of the plastic the plastic raw material to amputation hazards.
Recent events (2)
  • — I (O) $13653
  • — Z (S) $13653

View IKO Industries LTD.'s full OSHA safety record →