Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: UNITED CHESTER INDUSTRIES

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of UNITED CHESTER INDUSTRIES in 2000 ROBOTICS PLACE, FORT WORTH, TX 76118 (NAICS 238220). OSHA activity number 344957170.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch United Chester Industries — free Get an email when a new federal OSHA severe-injury report for United Chester Industries is published. One employer, no account, unsubscribe in one click.
Site address
2000 ROBOTICS PLACE
City
FORT WORTH
State
TX
ZIP
76118
Mailing
11540 PLANO ROAD, DALLAS, TX 75243
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
200
Ownership type
A

2 citations on file for this inspection.

1910.28 B09 I A

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Jan 11, 2021
Abate by
Feb 9, 2021
Penalty
Initial $8,675 · Current $0 Reduced
29 CFR 1910.28(b)(9)(i)(A): For fixed ladders that extend more than 24 feet (7.3 m) above a lower level, the employer did not ensure that each fixed ladder installed before November 19, 2018 is equipped with a personal fall arrest system, ladder safety system, cage, or well.   On or about October 02, 2020 and at times prior thereto, at a workplace located at 2000 Robotics Place, Fort Worth, Texas; the employer did not ensure that an approximately 36 feet fixed ladder attached to the building for employee use during RTU replacement had ladder safety system and did not have fall arrest system to protect employees from falling more than 16 to 30 feet to the lower level.
Recent events (3)
  • — F (S) $0
  • — C (S) $8675
  • — Z (S) $8675

1910.132 D01 I

Other-than-serious Gravity 10 1 instance 2 exposed
Issued
Jan 11, 2021
Abate by
Jul 20, 2022
Penalty
Initial $12,145 · Current $6,073 Reduced
29 CFR 1910.132(d)(1)(i):  The employer did not select, and have each affected employee use, the type of PPE that will protect the affected employee from the hazards identified in the hazard assessment:  On or about October 02, 2020 and at times prior thereto, at a workplace located at 2000 Robotics Place, Fort Worth, Texas; the employer did not perform any hazard assessment to protect employees of the hazards associated with falling more 16 feet to the lower level while climbing the fixed ladder without fall protection causing an employee's fractured pelvic and ribs.
Recent events (3)
  • — F (O) $6072.5
  • — C (S) $12145
  • — Z (S) $12145

View United Chester Industries's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344957170.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.