Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: U.S. DEPT OF THE INTERIOR - NATIONAL PARK SERVICE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of U.S. DEPT OF THE INTERIOR - NATIONAL PARK SERVICE in 189 MERIWETHER LEWIS PARK ROAD, HOHENWALD, TN 38462 (NAICS 712190). OSHA activity number 344960679.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Dept of the Interior - National Park Service — free Get an email when a new federal OSHA severe-injury report for U.S. Dept of the Interior - National Park Service is published. One employer, no account, unsubscribe in one click.
Site address
189 MERIWETHER LEWIS PARK ROAD
City
HOHENWALD
State
TN
ZIP
38462
Mailing
189 MERIWETHER LEWIS PARK ROAD, HOHENWALD, TN 38462
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
712190
Employees
6
Ownership type
D

6 citations on file for this inspection.

1910.243 E01 I

Serious Gravity 10 3 instances 1 exposed
Issued
Dec 8, 2020
Abate by
Dec 18, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.243(e)(1)(i): Power lawnmowers of the walk-behind, riding-rotary, and reel power lawnmowers were not guarded in accordance with the machine guarding requirements in 29 CFR 1910.212, General requirements for all machines:  a) On or about October 6, 2020 on the John Deere tractor, the HX15 Flex-Wing the power take-off shafts were unguarded from contact exposing employees to rotational caught-in hazards and the employer did not ensure spinning shaft guarding was installed.
Recent events (1)
  • — Z (S) $0

1910.253 B05 II G

Serious Gravity 5 2 instances 5 exposed
Issued
Dec 8, 2020
Abate by
Dec 18, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(5)(ii)(G): Cylinder valves were not closed when work was finished:  a) On or about October 6, 2020 in the maintenance garage the valves of an oxygen and acetylene cylinder were open exposing employees to fire hazards and the employer did not ensure valves were closed after work was finished.
Recent events (1)
  • — Z (S) $0

1910.303 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 8, 2020
Abate by
Dec 18, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled equipment was not installed and used in accordance with any instructions included in the listing or labeling:  a) On or about September 7, 2020 in the maintenance garage a metal junction box was used on the end of a flexible electrical cable to power a 240 volt welder exposing employees to electrical shock hazards and the employer did not ensure electrical equipment was installed and used in accordance with any instructions including in the listing and labeling.
Recent events (1)
  • — Z (S) $0

1910.334 A02 II

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 8, 2020
Abate by
Dec 18, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(ii): If there was a defect or evidence of damage that might have exposed an employee to injury, the defective or damaged item was not removed from service, and an employee was able to use it until repairs and tests necessary to render the equipment safe had been made:  a) On or about September 7, 2020 in the maintenance garage the Millermatic welder had a damaged section of outer insulation at the plug head exposing employees to electrical hazards and the employer did not remove the welder from service until repairs had been made.
Recent events (1)
  • — Z (S) $0

1910.334 A03 II

Serious Gravity 1 1 instance 3 exposed
Issued
Dec 8, 2020
Abate by
Dec 18, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(3)(ii): Attachment plugs and receptacles were connected or altered in a manner which prevented proper continuity of the equipment grounding conductor at the point where plugs were attached to receptacles:  a) On or about July 1, 2020 in the maintenance garage the Patton floor air circulation fan (Model: 1010MP, StyleSFE-74SP) was missing the grounding pin conductor from the plug exposing employees to electrical hazards and the employer did not ensure plugs were connected in a manner to provide continuity of the equipment grounding at the point where the plug was attached to the receptacle.
Recent events (1)
  • — Z (S) $0

1960.25 C

Other-than-serious 4 instances 5 exposed
Issued
Dec 8, 2020
Abate by
Jan 5, 2021
Penalty
Initial $0 · Current $0
29 CFR 1960.25(c): All areas and operations of each workplace, including office operations, did not inspected at least annually. More frequent inspections were not conducted in all workplaces where there was an increased risk of accident, injury, or illness due to the nature of the work performed. Sufficient unannounced inspections and unannounced follow-up inspections were not conducted by the agency to ensure the identification and abatement of hazardous conditions:  a) On or about October 6, 2020 at the facility safety and health hazards were found exposing employees to electrical, fire, and amputation hazards and the employer did not ensure inspections were being completed and inspections were frequent enough where there was an increased risk of accident, injury, or illness due to the nature of the work performed.
Recent events (1)
  • — Z (O) $0

View U.S. Dept of the Interior - National Park Service's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344960679.