Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: WEPFER MARINE, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WEPFER MARINE, INC. in 2821 CHANNEL AVENUE, MEMPHIS, TN 38113 (NAICS 488310). OSHA activity number 344962204.

Watch Wepfer Marine, INC. — free Get an email when a new federal OSHA severe-injury report for Wepfer Marine, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
WEPFER MARINE, INC.
Site address
2821 CHANNEL AVENUE
City
MEMPHIS
State
TN
ZIP
38113
Mailing
POST OFFICE BOX 13363, MEMPHIS, TN 38113
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
488310
Employees
25
Ownership type
A

6 citations on file for this inspection.

1910.303 G01

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $5851.00 · Current $3511.00 Reduced
29 CFR  1910.303(g)(1):Space about electric equipment. Sufficient access and working space was not provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment.  a) Area on top of the Oil separation room: On or about October 7, 2020, the electrical panel was blocked by a pipe flange, 5 gallon bucket, and a rolling office chair.
Recent events (2)
  • — I (S) $3510.6
  • — Z (S) $5851

1910.303 G02 I

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $7802.00 · Current $4681.00 Reduced
29 CFR  1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):   (a) Wharf Barge, above the oil room.  On or about October 7, 2020, the door to the panel breaker panel box was removed exposing employees to electrical hazards.
Recent events (2)
  • — I (S) $4681.2
  • — Z (S) $7802

1910.305 B01 II

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings were not effectively closed:  (a) Wharf Barge, oil room.  On or about October 7, 2020, the electrical panel breaker box had three unused breaker openings exposing workers to electrical shock.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1915.55 H

Serious Gravity 5 3 instances 3 exposed
Issued
Abate by
Penalty
Initial $7802.00 · Current $4681.00 Reduced
29 CFR  1915.55(h):Pressure regulators. Oxygen and fuel gas pressure regulators including their related gauges were not in proper working order while in use.  a) On the wharf barge.  On or about Oct 7, 2020, employees were exposed to regulator gauges on the Oxygen and Acetylene tanks that were damages exposing employees to serious injury from over pressurization.  b)  On the dry dock vessel.  On or about Oct 7, 2020, employees were exposed to regulator gauges on the Oxygen and Acetylene tanks that were damages exposing employees to serious injury from over pressurization.  c) On the repair vessel.  On or about Oct 7, 2020, employees were exposed to regulator gauges on the Oxygen and Acetylene tanks that were damages exposing employees to serious injury from over pressurization.
Recent events (2)
  • — I (S) $4681.2
  • — Z (S) $7802

1915.89 F02

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $9753.00 · Current $5852.00 Reduced
29 CFR  1915.89(f)(2):   The employer did not ensure that the authorized employee affix a tag directly to the energy-isolating device that clearly indicated the removal of the device from a safe or off position was prohibited when using tags-plus systems.  (a) Wharf Barge.  On or about October 7, 2020, employees were exposed to hazards of electrical shock when the electrical panel that is used to provide shore power to barges that was being serviced, did not have the lock engaged to protect employees from power being reconnected and/or energized again.
Recent events (2)
  • — I (S) $5851.8
  • — Z (S) $9753

1915.87 D01

Other-than-serious 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1915.87(d)(1):  The employer did not ensure that the placement, content, and amount of first aid supplies were adequate for the size and location of each worksite.  a) On the wharf barge, in the employee breakroom.  On or about Oct 7, 2020, the first aid kit did not have alcohol wipes, triple antibiotic, antiseptic wipes, lubricating eye drops and wound closures to provide adequate first aid
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View WEPFER MARINE, INC.'s full OSHA safety record →