Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: COFFEYVILLE SEKTAM INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of COFFEYVILLE SEKTAM INC in 509 N CLINE RD, COFFEYVILLE, KS 67337 (NAICS 332710). OSHA activity number 344982871.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Coffeyville Sektam INC — free Get an email when a new federal OSHA severe-injury report for Coffeyville Sektam INC is published. One employer, no account, unsubscribe in one click.
Site address
509 N CLINE RD
City
COFFEYVILLE
State
KS
ZIP
67337
Mailing
509 N CLINE RD, COFFEYVILLE, KS 67337
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
35
Ownership type
A

10 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 29, 2020
Abate by
Jan 26, 2021
Penalty
Initial $5,398 · Current $2,699 Reduced
29 CFR  1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  In the Mill Turn Area, employees engaged in production activities at the Chicago Drill press were exposed to struck-by hazards in that the point of operation was not guarded.  29 CFR 1903.19(c)(1) requires certification that the abatement of the above violation is complete
Recent events (2)
  • — I (S) $2699
  • — Z (S) $5398

1910.212 B

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 29, 2020
Abate by
Jan 26, 2021
Penalty
Initial $8,096 · Current $4,048 Reduced
29 CFR  1910.212(b):Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:  At the Mill Terminal, employees engaged in milling activities at the Clausing drill press, were exposed to struck-by hazards in that the drill press was not securely anchored to prevent walking or moving.  29 CFR 1903.19(c)(1) requires certification that the abatement of the above violation is complete
Recent events (2)
  • — I (S) $4048
  • — Z (S) $8096

1910.215 B09

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 29, 2020
Abate by
Jan 26, 2021
Penalty
Initial $8,096 · Current $4,048 Reduced
29 CFR  1910.215(b)(9):The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  At the Tooling Department, employees engaged in production activities at the Dayton Bench grinder in that the tongue guard was adjusted to approximately 5/8 of a inch from the grinding wheel, exposing employees to struck by and caught in hazards.  29 CFR 1903.19(c)(1) requires certification that the abatement of the above violation is complete
Recent events (2)
  • — I (S) $4048
  • — Z (S) $8096

1910.242 B

Serious Gravity 1 1 instance 1 exposed
Issued
Dec 29, 2020
Abate by
Jan 26, 2021
Penalty
Initial $4,048 · Current $2,024 Reduced
29 CFR  1910.242(b):Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  In the Induction and Heat Treat Area, employee used approximately 100 psi air pressure for cleaning purposes, exposing employees to struck-by and impalement hazards.  29 CFR 1903.19(c)(1) requires certification that the abatement of the above violation is complete
Recent events (2)
  • — I (S) $2024
  • — Z (S) $4048

1910.303 G01

Serious Gravity 1 1 instance 1 exposed
Issued
Dec 29, 2020
Abate by
Jan 26, 2021
Penalty
Initial $4,048 · Current $2,024 Reduced
29 CFR  1910.303(g)(1):Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  At the Deburr Department, employees engaged in maintenance activities were exposed to struck by, electrical, and fire hazards in that the service disconnect switches were obstructed by equipment.  29 CFR 1903.19(c)(1) requires certification that the abatement of the above violation is complete
Recent events (2)
  • — I (S) $2024
  • — Z (S) $4048

1910.305 B01 II

Serious Gravity 1 1 instance 1 exposed
Issued
Dec 29, 2020
Abate by
Jan 26, 2021
Penalty
Initial $4,048 · Current $2,024 Reduced
29 CFR  1910.305(b)(1)(ii):Unused openings in boxes, cabinets, or fittings were not effectively closed:  In the Deburr Area, employees were exposed to an electrical shock/burn hazards when using breaker switches on a breaker box with unused openings.  29 CFR 1903.19(c)(1) requires certification that the abatement of the above violation is complete
Recent events (2)
  • — I (S) $2024
  • — Z (S) $4048

1910.305 G01 IV A

Serious Gravity 1 1 instance 1 exposed
Issued
Dec 29, 2020
Abate by
Jan 26, 2021
Penalty
Initial $4,048 · Current $2,024 Reduced
29 CFR  1910.305(g)(1)(iv)(A):Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  At the Yoke Cell, employees engaged in manufacturing activities were exposed to fire and electrical shock hazards in that the flexible cord used to supply power to the skimmer attached to the Mori Seiki CNC lathe was used in lieu of fixed wiring exposing employees to fire and electrical shock hazards.  29 CFR 1903.19(c)(1) requires certification that the abatement of the above violation is complete
Recent events (2)
  • — I (S) $2024
  • — Z (S) $4048

1910.305 G01 IV D

Serious Gravity 1 1 instance 1 exposed
Issued
Dec 29, 2020
Abate by
Jan 26, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.305(g)(1)(iv)(D):Flexible cords and cables were attached to building surfaces:  At Yoke Cell, employees engaged in manufacturing activities were exposed to fire and electrical shock hazards in that a 110 volt flexible cord suppling power to the skimmer attached to the Mori Seiki CNC lathe was secured to the building surface.  29 CFR 1903.19(c)(1) requires certification that the abatement of the above violation is complete.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 F06 II

Serious Gravity 1 1 instance 1 exposed
Issued
Dec 29, 2020
Abate by
Jan 26, 2021
Penalty
Initial $4,048 · Current $2,024 Reduced
29 CFR  1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical  At the Polishing Station and Mill Terminal, the employer exposed employees to chemical hazards in that the employer failed to ensure that the Anti-Rust Oil container were properly labeled with the appropriate hazard warnings, exposing employees to eye irritation or skin irritation.  29 CFR 1903.19(c)(1) requires certification that the abatement of the above violation is complete
Recent events (2)
  • — I (S) $2024
  • — Z (S) $4048

1904.40 A

Other-than-serious 1 instance 35 exposed
Issued
Dec 29, 2020
Abate by
Jan 26, 2021
Penalty
Initial $1,350 · Current $675 Reduced
29 CFR  1904.40(a): The employer did not provide an authorized government representative the records within the four business hours.  At Coffeyville SEKTAM Inc, copies of the records kept under Part 1904 were not provided to an authorized government representative as required.  29 CFR 1903.19(c)(1) requires certification that the abatement of the above violation is complete.
Recent events (2)
  • — I (O) $675
  • — Z (O) $1350

View Coffeyville Sektam INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344982871.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.