Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AAT OMEGA LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of AAT OMEGA LLC in 6670 SPRING LAKE ROAD, KEYSTONE HEIGHTS, FL 32656 (NAICS 332322). OSHA activity number 344982988.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch AAT Omega LLC — free Get an email when a new federal OSHA severe-injury report for AAT Omega LLC is published. One employer, no account, unsubscribe in one click.
Establishment
AAT OMEGA LLC
Site address
6670 SPRING LAKE ROAD
City
KEYSTONE HEIGHTS
State
FL
ZIP
32656
Mailing
6670 SPRING LAKE ROAD, KEYSTONE HEIGHTS, FL 32656
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
31
Ownership type
A

5 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 3 exposed
Issued
Jan 12, 2021
Abate by
Feb 8, 2021
Penalty
Initial $9,446 · Current $9,446
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  a)  On or about October 19, 2020, in the fabrication shop, the employer did not have written specific energy control procedures that precisely outline the scope, rules and steps for the control of hazardous energy for the HAAS CNC VF-3, among other equipment with potential to store energy, exposing employees to caught-in and amputation hazards.
Recent events (1)
  • — Z (S) $9446

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 12, 2021
Abate by
Feb 8, 2021
Penalty
Initial $5,398 · Current $5,398
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a.  On or about October 19, 2020, at the metal fabrication area, the Scotchman band saw was being used without a protective guard at the blade, exposing employees to amputation hazards.
Recent events (1)
  • — Z (S) $5398

1904.29 A

Other-than-serious 3 instances 30 exposed
Issued
Jan 12, 2021
Abate by
Feb 8, 2021
Penalty
Initial $1,350 · Current $1,350
29 CFR  1904.29(a):A log of all Work-Related Injuries and Illnesses (OSHA Form 300), and/or the Summary of Work-Related Injuries and Illnesses, (OSHA Form 300A) and/or the Injury and Illness Incident Report (OSHA Form 301) or equivalent forms were not kept by the establishment:  a)  On or about October 19, 2020, throughout the fabrication plant, the employer did not use the OSHA-300 form, OSHA 301 form or equivalent forms to document recordable injuries and illnesses for current calendar year 2020.  b)  On or about October 19, 2020, throughout the fabrication plant, a copy of the OSHA-300, or equivalent form for all work related injuries and illnesses for years 2017, 2018 and 2019 were not kept for review as required by the standard.
Recent events (1)
  • — Z (O) $1350

1910.147 C06 I

Other-than-serious 1 instance 10 exposed
Issued
Jan 12, 2021
Abate by
Mar 2, 2021
Penalty
Initial $757 · Current $757
29 CFR  1910.147(c)(6)(i):The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  a)  On or about October 19, 2020, at the fabrication shop, periodic inspections of the energy control procedures were not being conducted as required, exposing employees to amputation hazards.
Recent events (1)
  • — Z (O) $757

1910.303 F02

Other-than-serious 1 instance 1 exposed
Issued
Jan 12, 2021
Abate by
Feb 8, 2021
Penalty
Initial $0 · Current $0
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  a.  On or about October 19, 2020, at the south wall of the fabrication building, the 480-V electric panel had circuit breakers being used that were not marked to indicate their purpose, exposing employees to electrical hazards.
Recent events (1)
  • — Z (O) $0

View AAT Omega LLC's full OSHA safety record →