OSHA Inspection: SPEARS CANEY INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SPEARS CANEY INC in 1609 CR 1900, CANEY, KS 67333 (NAICS 326122). OSHA activity number 345010102.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Spears Caney INC — free Get an email when a new federal OSHA severe-injury report for Spears Caney INC is published. One employer, no account, unsubscribe in one click.
Establishment
SPEARS CANEY INC
Site address
1609 CR 1900
City
CANEY
State
KS
ZIP
67333
Mailing
1609 CR 1900, CANEY, KS 67333
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326122
Employees
460
Ownership type
A

5 citations on file for this inspection.

1910.212 A05

Serious Gravity 5 2 instances 5 exposed
Issued
Jan 12, 2021
Abate by
Feb 8, 2021
Penalty
Initial $8,482 · Current $4,665 Reduced
29 CFR 1910.212(a)(5): Fan blade guard(s) were not provided where the periphery of the blades was less than seven feet from the floor or working level. Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch:  In the Subgated area, the Portacool 46 inches diameter fans had an approximately two inches opening on the blade guard, exposing employees to an amputation and laceration hazards.  29 CFR 1903.19(c)(1) requires certification that the abatement of the above violation is complete.
Recent events (2)
  • — I (S) $4665.1
  • — Z (S) $8482

1910.212 B

Serious Gravity 1 1 instance 5 exposed
Issued
Jan 12, 2021
Abate by
Feb 8, 2021
Penalty
Initial $6,361 · Current $3,499 Reduced
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:  In the Welding Shop, employees engaged in maintenance activities, were exposed to struck-by hazards in that the Jet 10 inch bench grinder was not securely anchored to prevent walking or moving.  29 CFR 1903.19(c)(1) requires certification that the abatement of the above violation is complete.
Recent events (2)
  • — I (S) $3498.55
  • — Z (S) $6361

1910.215 A04

Serious Gravity 5 1 instance 5 exposed
Issued
Jan 12, 2021
Abate by
Feb 8, 2021
Penalty
Initial $8,482 · Current $4,665 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:  In the Welding Shop, the Jet 10 inch bench grinder work rest was adjusted to approximately 1/2 inch from the wheel, increasing the potential for a part to become lodged against the wheel during grinding, exposing employees to a struck by and caught in hazard.  29 CFR 1903.19(c)(1) requires certification that the abatement of the above violation is complete.
Recent events (2)
  • — I (S) $4665.1
  • — Z (S) $8482

1910.215 B09

Serious Gravity 5 1 instance 5 exposed
Issued
Jan 12, 2021
Abate by
Feb 8, 2021
Penalty
Initial $8,482 · Current $4,665 Reduced
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  In the Welding Shop, the Jet 10 Bench Grinder tongue guard was adjusted to approximately one  inch from the grinding wheel, exposing employees to struck by and caught in hazards.  29 CFR 1903.19(c)(1) requires certification that the abatement of the above violation is complete.
Recent events (2)
  • — I (S) $4665.1
  • — Z (S) $8482

1910.1200 F06 II

Serious Gravity 1 4 instances 15 exposed
Issued
Jan 12, 2021
Abate by
Feb 8, 2021
Penalty
Initial $6,361 · Current $3,499 Reduced
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical.  In the gated and subgated areas, employee engaged in manufacturing and maintenance activities were exposed to chemical hazard which including eye irritation, skin irritation, and vision loss in that the employer did not maintain label, tag, or mark the container with the product identifier in the following instances:  a) Unlabeled cleaner in line 2 of Subgated area  b) Unlabeled chemical in AGV Maintenance area  C) Two containers of unlabeled chemicals in the Welding Shop  29 CFR 1903.19(c)(1) requires certification that the abatement of the above violation is complete.
Recent events (2)
  • — I (S) $3498.55
  • — Z (S) $6361

View Spears Caney INC's full OSHA safety record →