CINCINNATI, OH —
OSHA Inspection: ANTONIO GARCIA
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ANTONIO GARCIA in 3587 SECTION RD., CINCINNATI, OH 45237 (NAICS 238160). OSHA activity number 345011811.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ANTONIO GARCIA
- Site address
- 3587 SECTION RD.
- City
- CINCINNATI
- State
- OH
- ZIP
- 45237
- Mailing
- 3737 GLENWAY AVE, CINCINNATI, OH 45205
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Jan 26, 2021
- Penalty
- Initial $4,096 · Current $4,096
General-duty citation text
29 CFR 1926.501(b)(13):"Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems. On November 4, 2020, located on a residential roof, employees were exposed to a fall hazard while performing roofing work on a low pitch roof not utilizing any fall protection system. Potential fall height measured to be 20'-7" with a roof pitch of 4 in 12.
Recent events (1)
- — Z (S) $4096
1926.502 A02
- Issued
- Jan 26, 2021
- Penalty
- Initial $4,096 · Current $4,096
General-duty citation text
29 CFR 1926.502(a)(2): Employers shall provide and install all fall protection systems required by this subpart for an employee, and shall comply with all other pertinent requirements of this subpart before that employee begins the work that necessitates the fall protection. (A) Guardrail systems; (B) Safety net systems; or (C) Personal fall protection systems, such as personal fall arrest, travel restraint, or positioning systems. On November 4, 2020, located on a residential roof, employees were exposed to a fall hazard installing shingles onto a low pitch roof, and that the employer failed to install a fall protection system prior to employees performing the roofing work. Potential fall height measured to be 20'-7" with a roof pitch of 4 in 12.
Recent events (1)
- — Z (S) $4096
More inspections at Antonio Garcia
View Antonio Garcia's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345011811.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.