OSHA Inspection: MICHAEL BETKE DBA BETKE CONSTRUCTION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MICHAEL BETKE DBA BETKE CONSTRUCTION, INC. in 1933 W GREENLEAF AVE, CHICAGO, IL 60626 (NAICS 238160). OSHA activity number 345025902.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Michael Betke DBA Betke Construction, INC. — free Get an email when a new federal OSHA severe-injury report for Michael Betke DBA Betke Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1933 W GREENLEAF AVE
City
CHICAGO
State
IL
ZIP
60626
Mailing
3202 WHIRLAWAY CT, GRAYSLAKE, IL 60030
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

6 citations on file for this inspection.

1926.100 A

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 28, 2021
Abate by
May 10, 2021
Penalty
Initial $2,341 · Current $1,405 Reduced
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:  a)  On November 16, 2020, employees working below roofing operations exposed to struck-by hazards were not wearing hard hats.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1404.6
  • — Z (S) $2341

1926.102 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 28, 2021
Abate by
May 10, 2021
Penalty
Initial $2,926 · Current $1,756 Reduced
29 CFR 1926.102(a)(1): Employees were not provided with eye and face protection equipment when machines or operations present potential eye or face injury from physical, chemical, or radiation agents:     a) On November 16, 2020, employees were exposed to eye injury while operating a pneumatic nail gun without eye protection during roofing work.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1755.6
  • — Z (S) $2926

1926.451 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 28, 2021
Abate by
May 10, 2021
Penalty
Initial $2,926 · Current $1,756 Reduced
29 CFR 1926.451(e)(1):  Portable ladder, hook-on ladder, attachable ladder, stair tower, stairway-type ladder, ramp, runway, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was not used to access scaffold platforms more than 2 feet above or below a point of access:   a)  On November 16, 2020, employees were exposed to a fall hazards while accessing and egressing the work platform of a ladder jack scaffold.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1755.6
  • — Z (S) $2926

1926.451 G01 I

Serious Gravity 10 1 instance 2 exposed
Issued
Apr 28, 2021
Abate by
May 10, 2021
Penalty
Initial $4,096 · Current $2,458 Reduced
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system:  a)  On November 16, 2020, employees working from a ladder jack scaffold were exposed to a fall hazard of approximately 20 feet.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $2457.6
  • — Z (S) $4096

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Apr 28, 2021
Abate by
May 10, 2021
Penalty
Initial $0 · Current $0
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   a)  On November 16, 2020, employees performing roofing work were exposed to fall hazards from the roof of a two story home.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.503 A01

Other-than-serious Gravity 5 1 instance 4 exposed
Issued
Apr 28, 2021
Abate by
Aug 13, 2021
Penalty
Initial $2,926 · Current $0 Reduced
29 CFR 1926.503(a)(1):  The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:   a)  On or about November 16, 2020, employees were exposed to fall hazards while performing roofing work and the employer did not provide a training program to recognize fall hazards and the procedures to be followed in order to minimize those hazards.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2926

View Michael Betke DBA Betke Construction, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345025902.