Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NEVADA ARMY NATIONAL GUARD, AVIATION SUPPORT FACILITY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NEVADA ARMY NATIONAL GUARD, AVIATION SUPPORT FACILITY in 20000 ARMY AVIATION DRIVE, RENO, NV 89506 (NAICS 488190). OSHA activity number 345031173.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Nevada Army National Guard, Aviation Support Facility — free Get an email when a new federal OSHA severe-injury report for Nevada Army National Guard, Aviation Support Facility is published. One employer, no account, unsubscribe in one click.
Site address
20000 ARMY AVIATION DRIVE
City
RENO
State
NV
ZIP
89506
Mailing
20000 ARMY AVIATION DRIVE, RENO, NV 89506
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
488190
Employees
55
Ownership type
D

2 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 22, 2020
Abate by
Jan 20, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by flying chips or pieces of project parts.    (a) On or about November 19, 2020 and at times prior, for the employees exposed to struck-by hazards where a H-Frame bottle jack press was used to press out bears in the structural repair shop located at 20000 Army Aviation Drive, Reno, Nevada.
Recent events (1)
  • — Z (S) $0

1910.305 J02 IV

Serious Gravity 1 2 instances 4 exposed
Issued
Dec 22, 2020
Abate by
Jan 20, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.305(j)(2)(iv): A receptacle installed in a wet or damp location was not suitable for the location:  (a) On or about November 19, 2020 and at times prior, for the employees exposed to electrical hazards where an electric drinking water cooler was used without a ground fault circuit interrupter in the south aircraft hangar located at 20000 Army Aviation Drive, Reno, Nevada.  (b) On or about November 19, 2020 and at times prior, for the employees exposed to electrical hazards where an electric drinking water cooler was used without a ground fault circuit interrupter (GFCI) in the north aircraft hangar located at 20000 Army Aviation Drive, Reno, Nevada.
Recent events (1)
  • — Z (S) $0

View Nevada Army National Guard, Aviation Support Facility's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345031173.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.