SAN ANTONIO, TX —
OSHA Inspection: KENCON CONSTRUCTORS, LTD
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of KENCON CONSTRUCTORS, LTD in 10170 KRIEWALD RD, SAN ANTONIO, TX 78245 (NAICS 236220). OSHA activity number 345052724.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KENCON CONSTRUCTORS, LTD
- Site address
- 10170 KRIEWALD RD
- City
- SAN ANTONIO
- State
- TX
- ZIP
- 78245
- Mailing
- 4823 WHIRLWIND ST, SAN ANTONIO, TX 78217
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 2
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.1052 B01
- Issued
- Feb 12, 2021
- Penalty
- Initial $7,802 · Current $3,500 Reduced
General-duty citation text
29 CFR 1926.1052(b)(1):Foot traffic was not prohibited on stairways where the treads and/or landings of pan stairs were to be filled in with concrete or other material at a later date and stairs were not temporarily fitted with wood or other solid material at least to the top edge of each pan: On or about November 13, 2020, and times prior thereto, workers accessing the second level were exposed to a trip and fall hazard due to stairway landings were not temporarily filled with solid material.
Recent events (2)
- — I (O) $3500
- — Z (S) $7802
1926.1052 C01 II
- Issued
- Feb 12, 2021
- Penalty
- Initial $7,802 · Current $3,500 Reduced
General-duty citation text
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge: The main building: On or about November 13, 2020 and at times prior thereto, workers were exposed to a fall hazard while using a stairway to access the second floor that lacked a guardrail.
Recent events (2)
- — I (O) $3500
- — Z (S) $7802
1926.1052 C12
- Issued
- Feb 12, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1052(c)(12): Unprotected sides and edges of stairway landings were not provided with guardrail systems that meet the criteria contained in Subpart M of 29 CFR 1926: The main building: On or about November 13, 2020, and at times prior thereto, workers were exposed to a fall hazard while using a stairway to access the second floor whose landing did not have a guardrail.
Recent events (2)
- — I (O) $0
- — Z (S) $0
More inspections at Kencon Constructors, LTD
View Kencon Constructors, LTD's full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345052724.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.