Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MANUEL MORQUECHO

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MANUEL MORQUECHO in 7903 GENOVA COURT, WESTERVILLE, OH 43082 (NAICS 238130). OSHA activity number 345061279.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Manuel Morquecho — free Get an email when a new federal OSHA severe-injury report for Manuel Morquecho is published. One employer, no account, unsubscribe in one click.
Establishment
MANUEL MORQUECHO
Site address
7903 GENOVA COURT
City
WESTERVILLE
State
OH
ZIP
43082
Mailing
893 DERRER ROAD, COLUMBUS, OH 43204
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
5
Ownership type
A

5 citations on file for this inspection.

1926.20 B01

Serious Gravity 10 1 instance 5 exposed
Issued
Jan 28, 2021
Abate by
Feb 9, 2021
Penalty
Initial $4,096 · Current $2,048 Reduced
29 CFR  1926.20(b)(1):It shall be the responsibility of the employer to initiate and maintain such programs as may be necessary to comply with this part.  a. Located at 7903 Genova Court in Westerville, Ohio: On or about December 10, 2020, the employer did not develop and maintain an effective safety and health program to ensure hazards were identified and corrected onsite while employees performed framing work.
Recent events (2)
  • — I (S) $2048
  • — Z (S) $4096

1926.21 B02

Serious Gravity 10 1 instance 5 exposed
Issued
Jan 28, 2021
Abate by
Feb 9, 2021
Penalty
Initial $0 · Current $0
29 CFR  1926.21(b)(2):The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.  a. Located at 7903 Genova Court in Westerville, Ohio: On or about December 10, 2020, the employer did not train employees on the recognition and avoidance of unsafe conditions while performing framing work onsite.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 28, 2021
Penalty
Initial $4,096 · Current $2,048 Reduced
29 CFR  1926.501(b)(13):"Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502.  a. Located at 7903 Genova Court in Westerville, Ohio: On or about December 10, 2020, employees were performing framing work from the roof trusses without fall protection, thereby exposing employees to fall hazards from approximately twenty foot.
Recent events (2)
  • — I (S) $2048
  • — Z (S) $4096

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 28, 2021
Abate by
Feb 9, 2021
Penalty
Initial $3,511 · Current $1,756 Reduced
29 CFR  1926.1053(b)(1):When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.  a. Located at 7903 Genova Court in Westerville, Ohio: On or about December 10, 2020, a six foot fiberglass stepladder was used to access the roof. The ladder did not extend to and above the access point, thereby exposing employees to a fall hazard.
Recent events (2)
  • — I (S) $1755.5
  • — Z (S) $3511

1926.1053 B13

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 28, 2021
Abate by
Feb 9, 2021
Penalty
Initial $0 · Current $0
29 CFR  1926.1053(b)(13):The top or top step of a stepladder shall not be used as a step.  a. Located at 7903 Genova Court in Westerville, Ohio: On or about December 10, 2020, employees were using the top of a six-foot fiberglass stepladder to climb up in the roof trusses to access the roof, thereby exposing employees to a fall hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Manuel Morquecho's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345061279.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.