OSHA Inspection: INTERNATIONAL EQUIPMENT SOLUTIONS

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of INTERNATIONAL EQUIPMENT SOLUTIONS in 820 GLASER PARKWAY, AKRON, OH 44306 (NAICS 333120). OSHA activity number 345070833.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch International Equipment Solutions — free Get an email when a new federal OSHA severe-injury report for International Equipment Solutions is published. One employer, no account, unsubscribe in one click.
Site address
820 GLASER PARKWAY
City
AKRON
State
OH
ZIP
44306
Mailing
820 GLASER PARKWAY, AKRON, OH 44306
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333120
Employees
99
Ownership type
A

4 citations on file for this inspection.

1910.95 B01

Other-than-serious Gravity 5 1 instance 65 exposed
Issued
Mar 12, 2021
Abate by
Nov 15, 2021
Penalty
Initial $9,753 · Current $9,753
29 CFR  1910.95(b)(1):When employees were subjected to sound exceeding those listed in Table G-16, feasible administrative or engineering controls were not utilized:  On or about January 27, 2021, an employee who was performing welding work was exposed to continuous noise levels at 273% of the permissible daily exposure (8-hour, time-weighted average sound level of 90 dbA or equivalently, a dose of 100 percent), during the 440 minute sampling period.   Exposure calculations include a zero increment for the 40 minutes not sampled.
Recent events (3)
  • — P (O) $9753
  • — I (O) $9753
  • — Z (S) $9753

1910.179 J02 III

Other-than-serious Gravity 5 1 instance 65 exposed
Issued
Mar 12, 2021
Abate by
Apr 7, 2021
Penalty
Initial $9,753 · Current $4,876 Reduced
29 CFR  1910.179(j)(2)(iii) and (iv): Certification records that included the date of inspection, the signature of the person who performed the inspection and identified the hook or hoist chain inspected, were not created for monthly inspections of hooks and hoist chains:  On or about December 16, 2020, the employer did not possess certification records for monthly inspections of the hooks and hoist chains of the overhead cranes in the burn table area and welding bay, which are used daily to move material onto and off of the burn tables, as well as, move products to be welded in the welding bay.
Recent events (2)
  • — I (O) $4876
  • — Z (S) $9753

1904.10 A

Deleted Other-than-serious 2 instances 65 exposed
Issued
Mar 12, 2021
Abate by
Apr 7, 2021
Penalty
Initial $1,951 · Current $0 Reduced
29 CFR  1904.10(a): Where an employee's hearing test (audiogram) revealed that the employee had experienced a work-related Standard Threshold Shift (STS) in hearing in one or both ears, and the employee's total hearing level was 25 decibels (dB) or more above audiometric zero (averaged at 2000, 3000, and 4000 Hz) in the same ear(s) as the STS, the employer did not record the case on the OSHA 300 Log:  On or about December 16, 2020, the employer did not record OSHA recordable hearing loss on their 300 Log.   a). An employee had a STS in their right ear of 20 db and the employee's total hearing level was 46 db above audiometric zero in the same ear as the STS.   b). An employee had a STS in their right ear of 10 db and the employee's total hearing level was 51 db above audiometric zero in the same ear as the STS.
Recent events (2)
  • — I (O) $0
  • — Z (O) $1951

1910.157 E03

Other-than-serious 1 instance 99 exposed
Issued
Mar 12, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.157(e)(3):Portable fire extinguishers were not subjected to an annual maintenance check:  On or about December 16, 2020,  the Protegis Fire Safety portable fire extinguisher #34 in the welding bay did not receive an annual maintenance inspection.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View International Equipment Solutions's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345070833.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.