MARION, WI —
OSHA Inspection: GREAT LAKES VENEER INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of GREAT LAKES VENEER INC. in 222 S PARKVIEW AVE, MARION, WI 54950 (NAICS 321211). OSHA activity number 345086359.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GREAT LAKES VENEER INC.
- Site address
- 222 S PARKVIEW AVE
- City
- MARION
- State
- WI
- ZIP
- 54950
- Mailing
- 222 S PARKVIEW AVE, MARION, WI 54950
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321211
- Employees
- 165
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C04 II
- Issued
- Apr 2, 2021
- Abate by
- Apr 30, 2021
- Penalty
- Initial $7,461 · Current $7,461
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): a. The energy control procedure for the Paul Saw (Equipment # 249.00) did not identify all sources of potentially hazardous energy, such as but not limited to hydraulic and kinetic energies, exposing employees who were performing servicing and/or maintenance operations, to struck by and caught between or under hazards. b. The energy control procedure for the Paul Saw (Equipment # 249.00) did not describe the magnitudes of energies associated with the machine. The saw operated on 480VAC, and the Lockout Procedure created by the employer did not describe that magnitude of energy.
Recent events (1)
- — Z (S) $7461
1910.305 G01 IV A
- Issued
- Apr 2, 2021
- Penalty
- Initial $3,805 · Current $3,805
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Unless specifically permitted, flexible cords and cables may not be used as a substitute for the fixed wiring of a structure. Adjacent to the Moore Dryer, the employer did not ensure that a flexible cord was not used as a substitute for the fixed wiring of a structure, exposing employees to electrical and trip hazards. A flexible cord in use was affixed to electrical conduit and connected to a floor scale.
Recent events (1)
- — Z (S) $3805
More inspections at Great Lakes Veneer INC.
View Great Lakes Veneer INC.'s full OSHA safety record →
More inspections in this industry (NAICS 321211)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345086359.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.