Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GREAT LAKES VENEER INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of GREAT LAKES VENEER INC. in 222 S PARKVIEW AVE, MARION, WI 54950 (NAICS 321211). OSHA activity number 345086359.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Great Lakes Veneer INC. — free Get an email when a new federal OSHA severe-injury report for Great Lakes Veneer INC. is published. One employer, no account, unsubscribe in one click.
Site address
222 S PARKVIEW AVE
City
MARION
State
WI
ZIP
54950
Mailing
222 S PARKVIEW AVE, MARION, WI 54950
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321211
Employees
165
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 2, 2021
Abate by
Apr 30, 2021
Penalty
Initial $7,461 · Current $7,461
29 CFR  1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):  a.  The energy control procedure for the Paul Saw (Equipment # 249.00) did not identify all sources of potentially hazardous energy, such as but not limited to hydraulic and kinetic energies, exposing employees who were performing servicing and/or maintenance operations, to struck by and caught between or under hazards.  b.  The energy control procedure for the Paul Saw (Equipment # 249.00) did not describe the magnitudes of energies associated with the machine.  The saw operated on 480VAC, and the Lockout Procedure created by the employer did not describe that magnitude of energy.
Recent events (1)
  • — Z (S) $7461

1910.305 G01 IV A

Serious Gravity 1 1 instance 7 exposed
Issued
Apr 2, 2021
Penalty
Initial $3,805 · Current $3,805
29 CFR  1910.305(g)(1)(iv)(A): Unless specifically permitted, flexible cords and cables may not be used as a substitute for the fixed wiring of a structure.  Adjacent to the Moore Dryer, the employer did not ensure that a flexible cord was not used as a substitute for the fixed wiring of a structure, exposing employees to electrical and trip hazards. A flexible cord in use was affixed to electrical conduit and connected to a floor scale.
Recent events (1)
  • — Z (S) $3805

View Great Lakes Veneer INC.'s full OSHA safety record →