Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JELD-WEN, INCORPORATED

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of JELD-WEN, INCORPORATED in 825 SHINER ROAD, TOWANDA, PA 18848 (NAICS 321219). OSHA activity number 345104889.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Jeld-Wen, Incorporated — free Get an email when a new federal OSHA severe-injury report for Jeld-Wen, Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
825 SHINER ROAD
City
TOWANDA
State
PA
ZIP
18848
Mailing
PO BOX 311 825 SHINER ROAD, TOWANDA, PA 18848
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321219
Employees
450
Ownership type
A

2 citations on file for this inspection.

1910.147 D03

Other-than-serious Gravity 5 1 instance 1 exposed
Issued
Mar 9, 2021
Abate by
Apr 2, 2021
Penalty
Initial $6,583 · Current $5,266 Reduced
29 CFR  1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):  a) Line #1: Energy isolating devices for the downhill conveyor (19M1) were not operated in such a manner as to isolate the conveyor system from its energy source, on or about January 13, 2021.  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (O) $5266
  • — Z (S) $6583

1910.147 D04 I

Other-than-serious Gravity 5 1 instance 1 exposed
Issued
Mar 9, 2021
Abate by
Apr 2, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:  a) Line #1: Lockout or tagout devices were not affixed to energy isolating devices for the downhill conveyor (19M1), on or about January 13, 2021.  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

View Jeld-Wen, Incorporated's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345104889.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.