2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: DRYWALL SYSTEMS PLUS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DRYWALL SYSTEMS PLUS, INC. in BLDG 2702 SOLDIER SUPPORT CENTER, FORT CAMPBELL, KY 42223 (NAICS 238310). OSHA activity number 345124697.

Watch Drywall Systems Plus, INC. — free Get an email when a new federal OSHA severe-injury report for Drywall Systems Plus, INC. is published. One employer, no account, unsubscribe in one click.
Site address
BLDG 2702 SOLDIER SUPPORT CENTER
City
FORT CAMPBELL
State
KY
ZIP
42223
Mailing
102 MAX HURT DRIVE, MURRAY, KY 42071
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238310
Employees
4
Ownership type
A

1 citation on file for this inspection.

1926.405 G02 III

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $5461.00 · Current $0.00 Reduced
29 CFR  1926.405(g)(2)(iii):Splices. Flexible cords shall be used only in continuous lengths without splice or tap. Hard service flexible cords No. 12 or larger may be repaired if spliced so that the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced.  a)	Building 2702, Soldier Support Center, Remodeling office space, North Side. On or about January 26, 2021, the wiring for temporary lighting was improperly spliced exposing employees to electrical shock hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5461

View DRYWALL SYSTEMS PLUS, INC.'s full OSHA safety record →