ORLANDO, FL —
OSHA Inspection: HZ CONSTRUCTION, INC.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of HZ CONSTRUCTION, INC. in 4500 W SAND LAKE RD, ORLANDO, FL 32819 (NAICS 238320). OSHA activity number 345125371.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HZ CONSTRUCTION, INC.
- Site address
- 4500 W SAND LAKE RD
- City
- ORLANDO
- State
- FL
- ZIP
- 32819
- Mailing
- 220 N KIRKMAN RD., ORLANDO, FL 32811
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238320
- Employees
- 12
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.1153 D02 I
- Issued
- Apr 30, 2021
- Abate by
- Jun 17, 2021
- Penalty
- Initial $3,901 · Current $2,146 Reduced
90109015
General-duty citation text
29 CFR 1926.1153(d)(2)(i):The employer did not assess the exposure of each employee who was or may reasonably be expected to be exposed to respirable crystalline silica at or above the action level in accordance with either the performance option in paragraph (d)(2)(ii) or the scheduled monitoring option in paragraph (d)(2)(iii) of this section: a) At the Orange County Utilities' South Water Reclamation Facility, located at 4500 Sand Lake Rd. Orlando, Florida: On or about January 29, 2021, the Employer failed to assess the exposure of an employee who was exposed to concentrations of respirable crystalline silica, above the permissible exposure level, of 8-hour TWA of 85.3 micro-gr/m3, 1.7 times above the permissible exposure level of 50.0 micro-gr/m3. The employer failed to perform any exposure assessment. b) At the Orange County Utilities' South Water Reclamation Facility, located at 4500 Sand Lake Rd. Orlando, Florida: On or about January 29, 2021, the Employer failed to assess the exposure of an employee who was exposed to concentrations of respirable crystalline silica, above the action level, of 8-hour TWA of 45.4 micro-gr/m3, 1.8 times above the action level of 25.0 micro-gr/m3. The employer failed to perform any exposure assessment.
Recent events (2)
- — I (S) $2145.55
- — Z (S) $3901
1926.1153 G01
- Issued
- Apr 30, 2021
- Abate by
- Jun 17, 2021
- Penalty
- Initial $0 · Current $0
90109015
General-duty citation text
29 CFR 1926.1153(g)(1): The employer did not establish and implement a written exposure control plan: a) At the Orange County Utilities' South Water Reclamation Facility, located at 4500 Sand Lake Rd. Orlando, Florida: On or about January 29, 2021, the Employer exposed employees to respirable crystalline silica, in that the exposure control plan did not address sandblasting surface preparation operations.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1153 H01 I
- Issued
- Apr 30, 2021
- Abate by
- Jun 17, 2021
- Penalty
- Initial $0 · Current $0
90109015
General-duty citation text
29 CFR 1926.1153(h)(1)(i): The employer did not make medical surveillance available at no cost to the employee, and at a reasonable time and place, for each employee who was required under this section to use a respirator for 30 or more days per year: a) At the Orange County Utilities' South Water Reclamation Facility, located at 4500 Sand Lake Rd. Orlando, Florida: On or about January 29, 2021, an employee preparing the walls of Bay-A tank for lining application was expose to a 8-hour TWA of 85.3 micro-gr/m3 of respirable crystalline silica, 1.7 times above the permissible exposure level of 50.0 micro-gr/m3. The sampling was performed for 196 minutes on January 29, 2021. The employer did not make medical surveillance available to an employee that was or could be exposed to crystalline silica over the permissible exposure level. b) At the Orange County Utilities' South Water Reclamation Facility, located at 4500 Sand Lake Rd. Orlando, Florida: On or about January 29, 2021, an employee preparing the walls of Bay-A tank for lining application was expose to a 8-hour TWA of 45.3 micro-gr/m3 of respirable crystalline silica, 1.8 times above the action level of 25.0 micro-gr/m3. The sampling was performed for 198 minutes on January 29, 2021. The employer did not make medical surveillance available to an employee that was or could be exposed to crystalline silica over the permissible exposure level.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1153 I01
- Issued
- Apr 30, 2021
- Penalty
- Initial $0 · Current $0
90109015
General-duty citation text
29 CFR 1926.1153(i)(1): The employer did not ensure that each employee had access to safety data sheets labels on materials containing crystalline silica : a) At the Orange County Utilities' South Water Reclamation Facility, located at 4500 Sand Lake Rd. Orlando, Florida: On or about January 29, 2021, the employer exposed employees to respirable crystalline silica, in that the employer failed to provide access to safety data sheets on materials containing crystalline silica.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1153 E02
- Issued
- Apr 30, 2021
- Abate by
- May 26, 2021
- Penalty
- Initial $3,901 · Current $2,146 Reduced
056090109015
General-duty citation text
29 CFR 1926.1153(e)(2): Where respirator use is required by this section, the employer did not institute a respiratory protection program in accordance with 29 CFR 1910.134: a) At the Orange County Utilities' South Water Reclamation Facility, located at 4500 Sand Lake Rd. Orlando, Florida: On or about January 29, 2021, an employee engaged in surface preparation operation was exposed to Respirable Crystalline Silica at a Time Weighted Average (TWA) of 85.3 micrograms per cubic meter (�g/m3), 1.7 times above the permissible exposure level of 50.0 micro-gr/m3. The sampling was performed for 196 minutes on January 29, 2021. The employer did not include employees performing surface preparation operations into the company respiratory protection program. b) At the Orange County Utilities' South Water Reclamation Facility, located at 4500 Sand Lake Rd. Orlando, Florida: On or about January 29, 2021, an employee engaged in surface preparation operation was exposed to Respirable Crystalline Silica at a Time Weighted Average (TWA) of 45.4 micrograms per cubic meter (�g/m3), 1.8 times above the action level of 25.0 micro-gr/m3. The sampling was performed for 198 minutes on January 29, 2021. The employer did not include employees performing surface preparation operations into the company respiratory protection program.
Recent events (2)
- — I (S) $2145.55
- — Z (S) $3901
1910.134 F02
- Issued
- Apr 30, 2021
- Abate by
- May 26, 2021
- Penalty
- Initial $0 · Current $0
90109015
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: a) At the Orange County Utilities' South Water Reclamation Facility, located at 4500 Sand Lake Rd. Orlando, Florida: On or about January 29, 2021, the Employer failed to ensure that employees were fit-tested before they were required to use a tight-fit respirator.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 I07
- Issued
- Apr 30, 2021
- Abate by
- May 26, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(i)(7): Oil lubricated compressor(s) used to supply breathing air did not have a high-temperature or carbon monoxide alarm(s) or both: a) At the Orange County Utilities' South Water Reclamation Facility, located at 4500 Sand Lake Rd. Orlando, Florida: On or about January 29, 2021, the Employer failed to ensure that the air supplied from an oil-lubricated compressors to an employee's sandblaster hood was monitored to prevent carbon monoxide in the breathing air to exceed 10 ppm.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at HZ Construction, INC.
View HZ Construction, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238320)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345125371.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.