OSHA Inspection: ALDI INC. (CONNECTICUT)

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ALDI INC. (CONNECTICUT) in 360 TALCOTTVILLE ROAD, VERNON, CT 06066 (NAICS 445110). OSHA activity number 345135818.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Aldi INC. (Connecticut) — free Get an email when a new federal OSHA severe-injury report for Aldi INC. (Connecticut) is published. One employer, no account, unsubscribe in one click.
Site address
360 TALCOTTVILLE ROAD
City
VERNON
State
CT
ZIP
06066
Mailing
295 RYE STREET, SOUTH WINDSOR, CT 06074
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
445110
Employees
30
Ownership type
A

6 citations on file for this inspection.

1910.304 F01 IV

Serious Gravity 1 1 instance 30 exposed
Issued
Apr 8, 2021
Penalty
Initial $3,730 · Current $2,250 Reduced
29 CFR  1910.304(f)(1)(iv):  Overcurrent devices for circuits rated 600 volts, nominal, or less, were not readily accessible to each employee or authorized building management personnel:  Sprinkler Room:  On, or about, January 25, 2021, items such as a ladder, tote, boxes and a floor cleaner were stored in front of a GE Spectra Series panelboard and a Siemens PowerWall panelboard, limiting access to the overcurrent devices.
Recent events (2)
  • — I (S) $2250
  • — Z (S) $3730

1910.305 G01 IV A

Other-than-serious Gravity 5 2 instances 30 exposed
Issued
Apr 8, 2021
Penalty
Initial $4,974 · Current $2,250 Reduced
29 CFR  1910.305(g)(1)(iv)(A):  Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  A.  Sprinkler Room:  On, or about, January 25, 2021, a green extension cord was used to charge the Tennant floor cleaner. B.  Back Room:  On, or about, January 25, 2021, an orange extension cord was used to charge a Raymond pallet jack.
Recent events (2)
  • — I (O) $2250
  • — Z (S) $4974

1910.334 A02 II

Other-than-serious Gravity 5 3 instances 30 exposed
Issued
Apr 8, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.334(a)(2)(ii):  There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service:  Back Room:  On, or about, January 25, 2021, flexible cords were damaged: A.	Orange extension cord used to energize the Raymond pallet jack was damaged in three locations, exposing the inner coated conductors. B.	Black charging cord provided for the middle Raymond pallet jack had a crushed/split male end, exposing the inner components. C.	Black charging cord provided for the right Raymond pallet jack had a split out jacket, exposing the inner coated conductors.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.303 B07 IV

Other-than-serious 1 instance 30 exposed
Issued
Apr 8, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.303(b)(7)(iv):  There were damaged parts that adversely affected safe operation or mechanical strength of the equipment:  Back Room:  On, or about, January 25, 2021, electrical conduit that contained two receptacles boxes was pulled from the wall and was no longer supported.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.304 B04 II B

Other-than-serious 1 instance 30 exposed
Issued
Apr 8, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.304(b)(4)(ii)(B):  Where connected to a branch circuit supplying two or more receptacles or outlets, a receptacle supplied a total cord- and plug-connected load in excess of the maximum specified in Table S-4:  Breakroom:  On, or about, January 25, 2021, a GE microwave oven and a Cuisinart toaster oven were energized through the same wall receptacle.  The combined load on the receptacle was 17.8 amperes, which exceeded the maximum load allowed of 16 amperes.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 B02 I

Other-than-serious 1 instance 8 exposed
Issued
Apr 8, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:   Office:  On, or about, January 25, 2021, a wall mounted receptacle located under the Main Computer desk was not provided with a faceplate.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0