Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AMERIDGE POLYMER, INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of AMERIDGE POLYMER, INC in 906 EAST HERMITAGE ROAD NORTHEAST, ROME, GA 30161 (NAICS 325211). OSHA activity number 345136725.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ameridge Polymer, INC — free Get an email when a new federal OSHA severe-injury report for Ameridge Polymer, INC is published. One employer, no account, unsubscribe in one click.
Site address
906 EAST HERMITAGE ROAD NORTHEAST
City
ROME
State
GA
ZIP
30161
Mailing
906 EAST HERMITAGE RD. NE, ROME, GA 30161
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325211
Employees
18
Ownership type
A

12 citations on file for this inspection.

1910.30 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 30, 2021
Abate by
Aug 25, 2021
Penalty
Initial $3,901 · Current $3,901
29 CFR 1910.30(a)(1): The employer did not provide training for each employee who uses personal fall protection systems or who is required to be trained as specified elsewhere in this subpart before any employee is exposed to a fall hazard. The employer did not that ensure employees are trained in the requirements of this paragraph:  a) Baler Area: On or about 02/04/2021, an employee(s) tasked with completing service and maintenance activities on (Lummus Double Box) baler unit was potentially exposed to a fall hazard. Although the employee used a lanyard when accessing the catwalk on the third level of the baler, the employer failed to provide training in the use of lanyard with harness or conventional fall protection.  The third level baler measured approximately 20 feet from top of the catwalk to ground level.
Recent events (1)
  • — Z (S) $3901

1910.101 B

Serious Gravity 10 2 instances 10 exposed
Issued
Jul 30, 2021
Abate by
Aug 25, 2021
Penalty
Initial $5,461 · Current $5,461
29 CFR  1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6:  a) Maintenance Shop Area, Acetylene Storage Area - On or about 02/04/2021, employees are potentially exposed to struck-by and/or fire hazards, in that the employer failed to ensure that compressed gas cylinders containing argon, oxygen, propane, and acetylene were properly stored. Employees who worked in the proximity to unchained cylinders were not protected should a cylinder rupture or fall and become a projectile.  b) Back of the Facility- Propane Storage Tanks Area-  On or about 02/04/2021, employees are potentially exposed to struck-by and/or fire hazards, in that the employer failed to ensure that a compressed gas cylinder containing propane was properly stored. This tank was outdoors, unchained, near two large horizontal propane storage tanks.
Recent events (1)
  • — Z (S) $5461

1910.147 C01

Serious Gravity 5 1 instance 7 exposed
Issued
Jul 30, 2021
Abate by
Sep 16, 2021
Penalty
Initial $3,121 · Current $3,121
29 CFR  1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:   a) Entire Facility: On or about 02/04/2021, the employer failed to developed, and implemented a program for the control of hazardous energy use at the facility. Employees who service and/or maintain equipment such as, but not limited to, the Lummus Double Box Baler (model # unknown, S/N 17-545-5101), the Densifier #1 (model # unknown, S/N #1 JB/T 10391-2002) and the Gardner Denver Compressor (Model GD-D50) were not protected from unintentional start-up/re-energization of the energy sources. Energy sources used at the facility include, but are not limited to, electricity, pneumatic and hydraulics.
Recent events (1)
  • — Z (S) $3121

1910.147 F03 II D

Serious Gravity 5 1 instance 7 exposed
Issued
Jul 30, 2021
Abate by
Aug 11, 2021
Penalty
Initial $3,901 · Current $3,901
29 CFR  1910.147(f)(3)(ii)(D): Each authorized employee did not affix a personal lockout or tagout device to the group lockout device before working on the machine or equipment:  a). Baler Area: On or about 02/04/2021, employees were not protected from potential struck-by and/or caught in hazards, in that the employer did not ensure that each member of a three (3) man crew, applied their own lockout device(s) while working on equipment such as, but not limited to, the Lummus Double Box Baler (model # unknown, S/N 17-545-5101).
Recent events (1)
  • — Z (S) $3901

1910.253 B04 III

Serious Gravity 5 1 instance 10 exposed
Issued
Jul 30, 2021
Abate by
Aug 11, 2021
Penalty
Initial $3,121 · Current $3,121
29 CFR  1910.253(b)(4)(iii):Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet:  a) Maintenance Shop Area, Acetylene Storage Area - On or about 02/04/2021, the employer failed to ensure that cylinders containing compressed gases such as; but not limited to, oxygen, acetylene, propane were properly stored. Employees who worked in the proximity to unchained compressed gases were exposed fire and/or other hazards should a cylinders rupture/fall or inadvertently be exposed to a heat source.
Recent events (1)
  • — Z (S) $3121

1910.303 E01 II

Serious Gravity 1 4 instances 5 exposed
Issued
Jul 30, 2021
Abate by
Aug 25, 2021
Penalty
Initial $2,340 · Current $2,340
29 CFR  1910.303(e)(1)(ii):Other markings giving voltage, current, wattage, or other ratings as necessary.  On or about 02/04/2021, labeling to identify the voltage, current, wattage, and other required ratings was not marked on electrical equipment located throughout the facility. The electrical equipment includes, but is not limited to:  a) Employees were exposed to potential electrical hazards, in that the electrical panel (Labeled #DB1, DBC) located in the baler area near the air receiver/ expansion tank was not marked and/or labeled with the voltage, current, wattage, or other ratings as required.  b) Employees were exposed to potential electrical hazards, in that the electrical panel (Unlabeled) located in the baler area near the baler controller was not marked and/or labeled with the voltage, current, wattage, or other ratings as required.  c) Employees were exposed to potential electrical hazards, in that the electrical panel (V1) and (shut-off labeled WEF) located on side wall in the baler area was not marked and/or labeled with the voltage, current, wattage, or other ratings as required.  d) Employees were exposed to potential electrical hazards, in that the electrical panel (Labeled #LP 1)  and (shut-off labeled 20) located outside of the new compressor room in the densifier area was not marked and/or labeled with the voltage, current, wattage, or other ratings as required.
Recent events (1)
  • — Z (S) $2340

1910.303 G02 I A

Serious Gravity 5 4 instances 10 exposed
Issued
Jul 30, 2021
Abate by
Sep 16, 2021
Penalty
Initial $3,121 · Current $3,121
29 CFR  1910.303(g)(2)(i)(A): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or by location in a room, vault, or similar enclosure that is accessible only to qualified persons:  a) Employees were exposed to potential electrical hazards, in that the electrical panel (Labeled #DB1, DBC) located in the baler area near the air receiver/ expansion tank (480 V) 3-phase was not locked.  b) Employees were exposed to potential electrical hazards, in that the electrical panel (Unlabeled) located in the baler area near the baler controller (480 V) 3-phase was not locked.  The panel door was kept closed with a piece of electrical wire.  c) Employees were exposed to potential electrical hazards, in that the electrical panel (Labeled #V1) located on side wall in the baler area was not fully closed and locked.  d) Employees were exposed to potential electrical hazards, in that the electrical controller box door to the baler door could not close due to an abundance of wires.  e) Employees were exposed to potential electrical hazards, in that the electrical box with the door off (Labeled #LP 2)  was located in the new compressor room which had an unlocked and open door.
Recent events (1)
  • — Z (S) $3121

1910.304 F01 IV

Serious Gravity 1 2 instances 3 exposed
Issued
Jul 30, 2021
Abate by
Aug 11, 2021
Penalty
Initial $2,340 · Current $2,340
29 CFR  1910.304(f)(1)(iv):Overcurrent devices for circuits rated 600 volts, nominal, or less, were not readily accessible to each employee or authorized building management personnel:   a) Side Wall in the Baler Area- On or about 02/04/2021, employees were exposed to potential shock and/or fire hazards, in that demolition debris was blocking an electrical panel (480 volts) and an electrical On/Off switch on the side wall in the baler area. This blocked access to the electrical shut-offs used to power fans (ceiling and exhaust).  b) Area Outside of New Compressor Room- On or about 02/04/2021, employees were exposed to potential shock and/or fire hazards, in that a rail, storage items and miscellaneous parts of other equipment were placed approximately ten (10) - thirteen (13) inches or less in front of an electrical panel (LP 1) and an electrical On/Off switch (20) (120 volts)  with a rail, storage items and miscellaneous parts of other equipment. The electrical equipment  power lights and wall sockets.
Recent events (1)
  • — Z (S) $2340

1910.1200 E01

Serious Gravity 10 1 instance 10 exposed
Issued
Jul 30, 2021
Abate by
Sep 16, 2021
Penalty
Initial $5,461 · Current $5,461
29 CFR  1910.1200(e)(1):The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  (a) Facility-wide: On or about 02/04/2021, the employer did not develop, implement or maintain a written hazard communication program which described how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training would be met.   Chemicals used at the site includes, but is not limited to, polypropylene, acetylene, oxygen, and propane used for fork trucks and heating purposes.
Recent events (1)
  • — Z (S) $5461

1910.132 D02

Other-than-serious 1 instance 10 exposed
Issued
Jul 30, 2021
Abate by
Sep 16, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.132(d)(2):The employer did not verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated, the person certifying that the evaluation has been performed, the date(s) of the hazard assessment, and, which identifies the document as a certification of hazard assessment:  a) Entire Facility: On or about 02/04/2021, the employer exposed employees to fire, struck-by, thermal, and chemical hazards associated with the manufacturing operations dealing plastic recycling in that the employer did not certify that a workplace hazard assessment had been completed. 29 CFR  1910.132(d)(2):The employer did not verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated, the person certifying that the evaluation has been performed, the date(s) of the hazard assessment, and, which identifies the document as a certification of hazard assessment:  a) Entire Facility: On or about 02/04/2021, the employer exposed employees to fire, struck-by, thermal, and chemical hazards associated with the manufacturing operations dealing plastic recycling in that the employer did not certify that a workplace hazard assessment had been completed.
Recent events (1)
  • — Z (O) $5461

1910.157 C01

Other-than-serious 2 instances 10 exposed
Issued
Jul 30, 2021
Abate by
Aug 11, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:   a) Baler Area: On or about  02/04/2021 the employer exposed employees to fire hazards in that a (ABC) portable fire extinguisher was placed on floor and not mounted as required.  b) Maintenance Shop - near Entrance: On or about  02/04/2021 the employer exposed employees to fire hazards in that a (ABC) portable fire extinguisher was placed on floor and not mounted as required.
Recent events (1)
  • — Z (O) $0

1910.305 G01 IV A

Other-than-serious 1 instance 4 exposed
Issued
Jul 30, 2021
Abate by
Aug 25, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.305(g)(1)(iv)(A):Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a) Baler Area: On or about  02/04/2021 the employer exposed employees to electrical shock hazards in that an extension cord was used with a Receiver/ Expansion Tank(model # unknown) and solenoid as a permanent source for wiring.  b) Baler Area:
Recent events (1)
  • — Z (O) $0

View Ameridge Polymer, INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345136725.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.