MARIETTA, GA —
OSHA Inspection: FBS MANUFACTURING CORP.
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of FBS MANUFACTURING CORP. in 560 WEBB INDUSTRIAL DRIVE, MARIETTA, GA 30062 (NAICS 423310). OSHA activity number 345147748.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FBS MANUFACTURING CORP.
- Site address
- 560 WEBB INDUSTRIAL DRIVE
- City
- MARIETTA
- State
- GA
- ZIP
- 30062
- Mailing
- 3655 ATLANTA INDUSTRIAL DRIVE NW SUITE 200, ATLANTA, GA 30331
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423310
- Employees
- 25
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.37 B06
- Issued
- Aug 6, 2021
- Abate by
- Sep 1, 2021
- Penalty
- Initial $5,461 · Current $1,320 Reduced
General-duty citation text
29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color: (a) K&B Solutions Warehouse, front office area: On or about 02/16/2021, employees were not protected from potential smoke inhalation and/or other fire related hazards, in that exit signs above the only exit from the offices were damaged, inoperable, and not illuminate and lighting was not available in the event of a fire or power loss. (b) K&B Solutions Warehouse, paint shop: On or about 02/16/2021, employees were not protected from potential smoke inhalation and other fire related hazards, in that exit signs in a room full of flammable liquids were not illuminated at the only exit, and lighting was not available in the event of a fire or power loss. (c) K&B Solutions Warehouse, warehouse entrance from the lobby/showroom: On or about 02/16/2021, employees were exposed to trip hazards or potential smoke inhalation, in that an exit sign above the entrance to the front of the building was not illuminated in the event of a fire or loss of power.
Recent events (3)
- — J (S) $1320.25
- — C (S) $5461
- — Z (S) $5461
1910.178 L01 I
- Issued
- Aug 6, 2021
- Abate by
- Aug 18, 2021
- Penalty
- Initial $9,557 · Current $2,389 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i):The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): K&B Solutions Warehouse: On or about 02/16/2021, the employer did not ensure employees tasked with filling cabinetry orders were allowed to operate the company's Mitsubishi fork truck (Model #:FGCZ5N) and Mitsubishi (EOP) Order Picker at the facility were trained. This condition exposed employees to a industrial vehicle struck-by hazards.
Recent events (3)
- — J (S) $2389.25
- — C (S) $9557
- — Z (S) $9557
1910.178 P01
- Issued
- Aug 6, 2021
- Abate by
- Sep 1, 2021
- Penalty
- Initial $5,461 · Current $1,365 Reduced
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition: (a) K&B Solutions Warehouse: On or about 02/16/2021, the employer did not ensure that the Mitsubishi (Model FGCZ5N) Forklift Truck which was in need of repair due to defective or non-operable horns, was not taken out of service until it had been restored to safe operating conditions. This condition exposed employees to a struck-by hazard. (b) K&B Solutions Warehouse: On or about 02/16/2021, the employer did not ensure that the Mitsubishi EOP Order Picker Forklift Truck which was in need of repair due to defective or non-operable horns and strobe lights, was not taken out of service until it had been restored to safe operating conditions. This condition exposed employees to a struck-by hazard.
Recent events (3)
- — J (S) $1365.25
- — C (S) $5461
- — Z (S) $5461
1910.178 Q07
- Issued
- Aug 6, 2021
- Penalty
- Initial $0 · Current $1,365
General-duty citation text
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service: (a) K&B Solutions Warehouse: On or about 02/16/2021, the employer did not ensure that industrial trucks were examined before being placed in service. Employees operated a Mitsubishi fork truck (Model #:FGCZ5N) with a horn that was inoperable. The powered industrial trucks was not inspected before being placed into service. This condition exposed employees to a struck-by hazards. (b) K&B Solutions Warehouse: On or about 02/16/2021, the employer did not ensure that industrial trucks were examined before being placed in service. Employees operated a Mitsubishi EOP Order Picker Forklift with a horn that was inoperable and strobe light which was inoperable. The powered industrial trucks was not inspected before being placed into service. This condition exposed employees to a struck-by hazards.
Recent events (3)
- — J (S) $1365.25
- — C (S) $0
- — Z (S) $0
1910.305 B02 I
- Issued
- Aug 6, 2021
- Abate by
- Aug 18, 2021
- Penalty
- Initial $5,461 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: a) K&B Solutions Warehouse, Sanding Area: On or about 02/16/2021, the employer exposed employees to electrical shock hazards, in that 120-volt duplex outlets were not provided with a cover as employees used this outlet to plug in a fan. b) K&B Solutions Warehouse, Paint Room #1 and #2: On or about 02/16/2021, the employer exposed an employee to electrical shock hazards, in that wall outlets used to plug in tools, including dryers and portable lights, were not provided with covers while employees were engaged in painting activities.
Recent events (3)
- — J (S) $0
- — C (S) $5461
- — Z (S) $5461
1910.304 G05
- Issued
- Aug 6, 2021
- Abate by
- Sep 1, 2021
- Penalty
- Initial $5,461 · Current $1,365 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: K&B Solutions Warehouse, sanding department/area: On or about 02/16/2021, the employer exposed employees to electrical shock hazards, in that a 50-foot extension cord used to power lighting fixtures was missing the ground pin. Employees tasked with plugging and unplugging the extension cord at the start and end of shift.
Recent events (3)
- — J (S) $1365.25
- — C (S) $5461
- — Z (S) $5461
1910.305 G01 IV A
- Issued
- Aug 6, 2021
- Abate by
- Sep 1, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: K&B Solutions Warehouse, sanding area: On or about 02/16/2021, the employer exposed employees to electrical shock hazards, in that an extension cord used as a substitute for fixed wiring to power light fixtures, was missing the ground pin.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.305 G02 III
- Issued
- Aug 6, 2021
- Abate by
- Sep 1, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: K&B Solutions Warehouse, fabricating area: On or about 02/16/2021, the employer exposed employees electrical shock hazards, in that adequate strain relief was not provided for an extension cord used to power equipment such as, but not limited to; the company's router. The casing of the extension cord used in the cabinet fabrication/customizing area was taped together as a temporary repair.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.28 B01 I C
- Issued
- Aug 6, 2021
- Abate by
- Sep 1, 2021
- Penalty
- Initial $136,532 · Current $34,133 Reduced
General-duty citation text
29 CFR 1910.28(b)(1)(i)(C): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by a personal fall protection systems, such as personal fall arrest, travel restraint, or positioning systems: K&B Solutions Warehouse, warehouse area Aisle #13 - Row K: On 02/13/2021, the employer failed to ensure that fall protection was used by employees exposed to fall hazards of approximately 15 feet while working from a Mitsubishi Electric Order Picker (EOP).
Recent events (3)
- — J (W) $34133
- — C (W) $136532
- — Z (W) $136532
More inspections at FBS Manufacturing Corp.
View FBS Manufacturing Corp.'s full OSHA safety record →
More inspections in this industry (NAICS 423310)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345147748.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.