Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GONZALEZ ROOFING, INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GONZALEZ ROOFING, INC in 3025 LAKE ELLEN DRIVE, TAMPA, FL 33606 (NAICS 238160). OSHA activity number 345148233.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Gonzalez Roofing, INC — free Get an email when a new federal OSHA severe-injury report for Gonzalez Roofing, INC is published. One employer, no account, unsubscribe in one click.
Site address
3025 LAKE ELLEN DRIVE
City
TAMPA
State
FL
ZIP
33606
Mailing
22 JETT LOOP, APOPKA, FL 32712
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
8
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 3 exposed
Issued
Mar 11, 2021
Penalty
Initial $4,096 · Current $4,096
29 CFR  1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   a) 3025 Lake Ellen Drive, Tampa, FL Job Site - Three employees were observed installing shingles on a 6 in 12 sloped roof without any type of fall protection, on or about February 12, 2021. The eave to ground height was 11 feet 3 inches.
Recent events (1)
  • — Z (S) $4096

1926.1053 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 11, 2021
Penalty
Initial $2,926 · Current $2,926
29 CFR  1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support:    a) 3025 Lake Ellen Drive, Tampa, FL Job Site - The portable extension ladder , used to gain access to the roof, only extended approximately 1.5 feet past the edge of the roof, on or about February 12, 2021.
Recent events (1)