PAYSON, AZ —
OSHA Inspection: MAZATZAL HOTEL & CASINO
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of MAZATZAL HOTEL & CASINO in HWY 87 MILEPOST 25, PAYSON, AZ 85541 (NAICS 721120). OSHA activity number 345151765.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MAZATZAL HOTEL & CASINO
- Site address
- HWY 87 MILEPOST 25
- City
- PAYSON
- State
- AZ
- ZIP
- 85541
- Mailing
- P.O. BOX 1820, PAYSON, AZ 85547
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 721120
- Employees
- 200
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.140 C16
- Issued
- Apr 14, 2021
- Abate by
- Jun 1, 2021
- Penalty
- Initial $8,778 · Current $8,778
General-duty citation text
29 CFR 1910.140(c)(16): The employer did not ensure that personal fall protection systems and their components are used exclusively for employee fall protection and not for any other purpose, such as hoisting equipment or materials. MAINTENANCE SHOP: Employees performing scheduled maintenance on ventilation equipment are anchoring personal fall arrest systems to ventilation equipment not designed exclusively for fall protection, exposing them to fall hazards.
Recent events (2)
- — P (S) $8778
- — Z (S) $8778
1910.147 C01
- Issued
- Apr 14, 2021
- Abate by
- Jun 1, 2021
- Penalty
- Initial $8,778 · Current $8,778
General-duty citation text
29 CFR 1910.147(c)(1):The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: FACILITY WIDE: Employees perform maintenance on HVAC and boiler equipment that require lock out tag out procedures. The employer had not established a program consisting of energy control procedures, employee training and inspections to ensure the startup or release of stored energy could not occur while servicing or maintenance, exposing employees to stored energy hazards.
Recent events (2)
- — P (S) $8778
- — Z (S) $8778
1910.101 A
- Issued
- Apr 14, 2021
- Abate by
- Apr 26, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.101(a):The employer did not determine that compressed gas cylinders under his control were in a safe condition to the extent that can be determined by visual or other inspections conducted as prescribed in the Hazardous Materials Regulations: SHOP No. 4: The glass covers to two regulator gauges on a carbon dioxide cylinder were broken, exposing employees to hazards associated with compressed gas cylinders.
Recent events (1)
- — Z (O) $0
1910.178 L04 III
- Issued
- Apr 14, 2021
- Abate by
- May 10, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: MAINTENANCE SHOP: The employer did not ensure that employees operating a forklift were evaluated at least once every three years, exposing employees to struck-by hazards..
Recent events (2)
- — P (O) $0
- — Z (O) $0
1910.253 B02 IV
- Issued
- Apr 14, 2021
- Abate by
- Apr 26, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(2)(iv):Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use: MAINTENANCE SHOP: Two compressed gas cylinders were stored without protective caps, exposing employees to struck-by and fire hazards.
Recent events (2)
- — P (O) $0
- — Z (O) $0
1910.334 A01
- Issued
- Apr 14, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(1):Flexible electric cords were fastened with staples or otherwise hung in such a fashion as could damage the outer jacket or insulation: MAINTENANCE SUPERVISORS OFFICE: The flexible cord to a drop pendant light hung over a workbench was fixed in location by staples, exposing employees to electrical and fire hazards.
Recent events (1)
- — Z (O) $0
More inspections at Mazatzal Hotel & Casino
View Mazatzal Hotel & Casino's full OSHA safety record →
More inspections in this industry (NAICS 721120)
More inspections in AZ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345151765.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.