Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DEPARTMENT OF NAVY-NAVAL SURFACE WARFARE CENTER CORONA

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of DEPARTMENT OF NAVY-NAVAL SURFACE WARFARE CENTER CORONA in REWS-T-100-109 NAVAL BASE CORONADO-SAN CLEMENTE, CORONADO, CA 92155 (NAICS 928110). OSHA activity number 345154678.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Department of Navy-Naval Surface Warfare Center Corona — free Get an email when a new federal OSHA severe-injury report for Department of Navy-Naval Surface Warfare Center Corona is published. One employer, no account, unsubscribe in one click.
Site address
REWS-T-100-109 NAVAL BASE CORONADO-SAN CLEMENTE
City
CORONADO
State
CA
ZIP
92155
Mailing
1999 FOURTH STREET, NORCO, CA 92860
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
Yes
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
928110
Employees
80
Ownership type
D

8 citations on file for this inspection.

1910.142 B11

Serious Gravity 5 3 instances 13 exposed
Issued
Jul 15, 2021
Abate by
Oct 8, 2021
Penalty
Initial $0 · Current $0
29 CFR 1910.142(b)(11): All heating, cooking, and water heating equipment used in the temporary labor camp site was not installed in accordance with State and local ordinances, codes, and regulations governing such installations.  (a) San Clemente Island SCORE Berthing REWS T-100, 101, 102 south side exterior utility closets: The Controlling Employer did not ensure that water heaters were equipped with required earthquake straps per applicable California Plumbing Code Section 507.2 which requires that all water heaters be supported and strapped to prevent movement during an earthquake. Two metal straps, not less than 22 gauge, nor less than 5/8-inch wide shall be used. This potentially exposed employees living in each unit to fire and explosion hazards.
Recent events (1)
  • — Z (S) $0

1910.142 B04

Serious Gravity 5 4 instances 18 exposed
Issued
Jul 15, 2021
Abate by
Nov 17, 2021
Penalty
Initial $0 · Current $0
29 CFR 1910.142(b)(4): Wooden floors of temporary labor camp shelter(s) were not of smooth and tight construction. The floors of temporary labor camp shelter(s) were not kept in good repair.  (a) San Clemente Island SCORE Berthing REWS T-101 and T-104 south end interior side of back doors by Washing Machines and T-106, 108 at front doors: The Controlling Employer did not ensure that floors were in good repair. Unsecured plywood was placed over structurally unsound deck and elevated higher than surrounding floor. This exposed employees living in each unit to slips and trips.
Recent events (2)
  • — P (S) $0
  • — Z (S) $0

1910.157 E02

Serious Gravity 5 9 instances 40 exposed
Issued
Jul 15, 2021
Abate by
Oct 8, 2021
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2): The controlling employer did not ensure that portable fire extinguishers were visually inspected at least monthly.  (a) San Clemente Island SCORE Berthing REWS-T-100 through108: The Controlling Employer did not ensure that fire extinguishers were inspected monthly which exposed employees living in each unit to potential injury from fire hazards.
Recent events (1)
  • — Z (S) $0

1910.157 E03

Serious Gravity 5 9 instances 40 exposed
Issued
Jul 15, 2021
Abate by
Oct 8, 2021
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check:  (a) San Clemente Island SCORE Berthing REWS-T-100 through108: The Controlling Employer did not ensure that portable fire extinguishers were subjected to an annual maintenance check. This potentially exposed employees living in each unit to injury from fire hazards.
Recent events (1)
  • — Z (S) $0

1910.28 B11 II

Serious Gravity 5 1 instance 9 exposed
Issued
Jul 15, 2021
Abate by
Nov 17, 2021
Penalty
Initial $0 · Current $0
29 CFR 1910.28(b)(11)(ii):29 CFR 1910.28(b)(11)(ii): The controlling employer did not ensure that each flight of stairs having at least 3 treads and at least 4 risers were equipped with stair rail systems and handrails as described in 29 CFR 1910.28 Table D-2-Stairway Handrail Requirements.  (a) San Clemente Island SCORE Berthing REWS T-103 and T-104 west end of conjoined porch steps with 3 treads and 4 risers were not equipped with a stair rail system as required by applicable standard which could lead to employees falling off of steps and sustaining injury.
Recent events (2)
  • — P (S) $0
  • — Z (S) $0

1910.142 B08

Other-than-serious 18 instances 40 exposed
Issued
Jul 15, 2021
Abate by
Nov 17, 2021
Penalty
Initial $0 · Current $0
29 CFR 1910.142(b)(8): Screen doors of temporary labor camp shelter(s) were not equipped with self-closing devices:  (a) San Clemente Island SCORE Berthing REWS T-100 through T-108: Screen doors were not equipped with self closing devices. Each trailer is equipped with two screen doors one on the north side and one on the south side of the building totaling 18 doors . Many of these screen doors are used by employees on a daily basis. In the absence of self closing devices, screen door may not close completely after use. Unclosed screen doors can allow rodents and other vermin to enter trailer units which can expose employees to rodent and mosquito borne diseases such as Hantavirus and West Nile Virus.
Recent events (2)
  • — P (O) $0
  • — Z (O) $0

1910.29 B05

Other-than-serious 1 instance 5 exposed
Issued
Jul 15, 2021
Abate by
Oct 8, 2021
Penalty
Initial $0 · Current $0
29 CFR 1910.29(b)(5): The controlling employer did not ensure that guardrails met the requirement that mid rails, screens, mesh, intermediate vertical members, solid panels, and other equivalent intermediate members are capable of withstanding, without failure, a force of at least 150 pounds (667 N) applied in any downward or outward direction at any point along the intermediate member.  (a) San Clemente Island SCORE Berthing REWS T-108 the top of a stairway leading to the trailer a mid rail has rusted through and broken free of the railing on one end. The break easily reduces the mid rails ability to withstand forces of 150 pounds without failure. Workers could potentially get cut on rusted end or fall through between the mid and top rail.
Recent events (1)
  • — Z (O) $0

1910.29 F04

Other-than-serious 1 instance 9 exposed
Issued
Jul 15, 2021
Abate by
Oct 8, 2021
Penalty
Initial $0 · Current $0
29 CFR 1910.29(f)(4): Openings in stair rails. The controlling employer did not ensure that no opening in a stair rail system exceeds 19 inches (48 cm) at its least dimension.  (a) San Clemente Island SCORE Berthing REWS-T-101 and T-102 conjoined porch: The controlling employer allowed employees to use steps to access living quarters which had gaps larger than 19 inches. This condition potentially exposed employees to injury which could result from slips, trips and falls while using steps.
Recent events (1)
  • — Z (O) $0

View Department of Navy-Naval Surface Warfare Center Corona's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345154678.