Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SUPER BUILDERS, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SUPER BUILDERS, LLC in 1116 PETRUS CT., DAYTON, OH 45458 (NAICS 238130). OSHA activity number 345165377.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Super Builders, LLC — free Get an email when a new federal OSHA severe-injury report for Super Builders, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
SUPER BUILDERS, LLC
Site address
1116 PETRUS CT.
City
DAYTON
State
OH
ZIP
45458
Mailing
2702 TYLERSVILLE ROAD #65, INDIAN SPRINGS, OH 45015
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
4
Ownership type
A

2 citations on file for this inspection.

1926.502 A02

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Apr 9, 2021
Penalty
Initial $4,505 · Current $0 Reduced
29 CFR 1926.502(a)(2): Employers shall provide and install all fall protection systems required by this subpart for an employee, and shall comply with all other pertinent requirements of this subpart before that employee begins the work that necessitates the fall protection. (A)  Guardrail systems;  (B)  Safety net systems; or  (C)  Personal fall protection systems, such as personal fall arrest, travel restraint, or positioning systems.  On February 23, 2021, located on the north side of a residential roof structure, an employee was exposed to a fall hazard while standing on a steep pitch roof installing sheathing and framing and that the employer failed to install a fall protection system before the employee performed the framing work. Potential fall height was measured 13'-5" with a roof pitch of 12 in 12.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4505

1926.501 B13

Deleted Repeat Gravity 10 1 instance 1 exposed
Issued
Apr 9, 2021
Penalty
Initial $9,011 · Current $0 Reduced
29 CFR  1926.501(b)(13):"Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.  On February 23, 2021, located on the north side of a residential structure, an employee was exposed to a fall hazard installing sheathing and framing onto a steep pitch roof not utilizing any fall protection system. Potential fall height measured 13'-5" with a roof pitch of 12/12.   The Super Builders, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR  1926.501(b)(13), which was contained in OSHA inspection number 1191924 citation number 2, item number 2 and was affirmed as a final order on 1/31/2017, with respect to a workplace located at 1322 Bourdeaux Way, Centerville, OH 45458.
Recent events (2)
  • — I (R) $0
  • — Z (R) $9011

View Super Builders, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345165377.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.