On , OSHA opened a follow-up health inspection of YC52 LLC in 2947 FELTON ROAD, EAST NORRITON, PA 19401 (NAICS 321219). OSHA activity number 345167456.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch YC52 LLC — free Get an email when a new federal OSHA severe-injury report for YC52 LLC is published. One employer, no account, unsubscribe in one click.
Establishment
YC52 LLC
Site address
2947 FELTON ROAD
City
EAST NORRITON
State
PA
ZIP
19401
Mailing
2947 FELTON ROAD, EAST NORRITON, PA 19401
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321219
Employees
8
Ownership type
A

14 citations on file for this inspection.

1910.107 B01

Repeat Gravity 5 1 instance 2 exposed
Issued
May 25, 2021
Abate by
Jun 21, 2021
Penalty
Initial $7,802 · Current $7,802
29 CFR 1910.107(b)(1): The spray booth was not substantially constructed of steel, securely and rigidly supported, or of concrete or masonry.  a) Spray Booth: On or about February 26, 2021, employees that spray paint wooden baseball bats with flammable stains and coatings were exposed to a fire hazard in that the booth was constructed of wood framing covered by particle board.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.  Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photograph or video evidence of abatement or other written records.  YC52 LLC, WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD 29 CFR 1910.107(b)(1) WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 1469277, CITATION NUMBER 1, ITEM NUMBER 1a, AND WAS AFFIRMED AS A FINAL ORDER ON SEPTEMBER 30, 2020, WITH RESPECT TO A WORKPLACE LOCATED AT 2497 FELTON RD, EAST NORRITON PA.
Recent events (1)
  • — Z (R) $7802

1910.107 B02

Repeat Gravity 5 1 instance 2 exposed
Issued
May 25, 2021
Abate by
Jun 21, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.107(b)(2):The interior surface of spray booth(s) were not smooth and continuous without edges and otherwise designed to prevent pocketing of residues and to facilitate cleaning and washing without injury:  a) Spray Booth: On or about February 26, 2021, employees that spray paint wooden baseball bats with flammable stains and coatings were exposed to a fire hazard in that the interior walls on the spray booth were not smooth to prevent residue buildup and facilitate cleaning and washing.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.  Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photograph or video evidence of abatement or other written records.  YC52 LLC, WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD 29 CFR 1910.107(b)(2) WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 1469277, CITATION NUMBER 1, ITEM NUMBER 1b, AND WAS AFFIRMED AS A FINAL ORDER ON SEPTEMBER 30, 2020, WITH RESPECT TO A WORKPLACE LOCATED AT 2497 FELTON RD, EAST NORRITON PA.
Recent events (1)
  • — Z (R) $0

1910.107 B05 I

Repeat Gravity 5 1 instance 2 exposed
Issued
May 25, 2021
Abate by
Jun 21, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.107(b)(5)(i):There were no visible gauges, audible alarms or pressure activated devices installed in paint spray booths to indicate or ensure that the required air speed was maintained.  a) Spray Booth: On or about February 26, 2021,  employees that spray paint wooden baseball bats with flammable stains and coatings were exposed to a fire hazard as well as over exposure to the stains and coatings in that the booth was not equipped with devices that would ensure that the ventilation in the booth was meeting a minimum of 100 linear feet per minute.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.  Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photograph or video evidence of abatement or other written records.  YC52 LLC, WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD 29 CFR 1910.107(b)(5)(i) WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 1469277, CITATION NUMBER 1, ITEM NUMBER 1c, AND WAS AFFIRMED AS A FINAL ORDER ON SEPTEMBER 30, 2020, WITH RESPECT TO A WORKPLACE LOCATED AT 2497 FELTON RD, EAST NORRITON PA.
Recent events (1)
  • — Z (R) $0

1910.107 B05 IV

Repeat Gravity 5 1 instance 2 exposed
Issued
May 25, 2021
Abate by
Jun 21, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.107(b)(5)(iv):Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers:  a) Spray Booth: On or about February 26, 2021, employees that spray paint wooden baseball bats with flammable stains and coatings were exposed to a fire hazard in that the booth was not equipped with an automatic suppression system both in the booth and in the ductwork.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.  Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photograph or video evidence of abatement or other written records.  YC52 LLC, WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD 29 CFR 1910.107(b)(5)(iv) WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 1469277, CITATION NUMBER 1, ITEM NUMBER 1d, AND WAS AFFIRMED AS A FINAL ORDER ON SEPTEMBER 30, 2020, WITH RESPECT TO A WORKPLACE LOCATED AT 2497 FELTON RD, EAST NORRITON PA.
Recent events (1)
  • — Z (R) $0

1910.107 B06

Repeat Gravity 5 1 instance 2 exposed
Issued
May 25, 2021
Abate by
Jun 21, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.107(b)(6):Spray booth(s)�having a�frontal area�larger than�9 square�feet did�not have�metal deflectors�or curtains�not less�than 2�1/2 inches�deep installed�at the�upper outer�edge of�the booth�over the�opening:  a) Spray Booth: On or about February 26, 2021, employees that spray paint wooden baseball bats with flammable stains and coatings were exposed to the hazards of over-exposure to hazardous chemicals, and ignition of those chemicals in that a deflector was not installed at the upper edge of the opening of the booth which could reduce the turbulence in the booth and provide for adequate ventilation.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.  Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photograph or video evidence of abatement or other written records.  YC52 LLC, WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD 29 CFR 1910.107(b)(6) WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 1469277, CITATION NUMBER 1, ITEM NUMBER 1e, AND WAS AFFIRMED AS A FINAL ORDER ON SEPTEMBER 30, 2020, WITH RESPECT TO A WORKPLACE LOCATED AT 2497 FELTON RD, EAST NORRITON PA.
Recent events (1)
  • — Z (R) $0

1910.107 C02

Repeat Gravity 5 1 instance 2 exposed
Issued
May 25, 2021
Abate by
Jun 21, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.107(c)(2):Open flame or spark producing equipment was located in the spraying area or within 20 feet thereof, and was not separated by a partition.  a) Spray Booth: On or about February 26, 2021, employees that spray paint wooden bats were exposed to ignition hazards due to the presence of electrical equipment not separated by an adequate partition or of proper classification within 20' of the spraying area.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.  Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photograph or video evidence of abatement or other written records.  YC52 LLC, WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD 29 CFR 1910.107(c)(2) WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 1469277, CITATION NUMBER 1, ITEM NUMBER 1f, AND WAS AFFIRMED AS A FINAL ORDER ON SEPTEMBER 30, 2020, WITH RESPECT TO A WORKPLACE LOCATED AT 2497 FELTON RD, EAST NORRITON PA.
Recent events (1)
  • — Z (R) $0

1910.107 C07

Repeat Gravity 5 1 instance 2 exposed
Issued
May 25, 2021
Abate by
Jun 21, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.107(c)(7):Electric lamps outside of but within 20 feet of spraying area(s), and not separated therefrom by partition(s), were not totally enclosed to prevent the falling of hot particles:  a) Spray Booth: On or about February 26, 2021, employees that spray paint wooden bats with flammable stains and coatings were exposed to the ignition of flammable vapors in that electrical lighting which was located above and within 20' of the face of the booth were not enclosed.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.  Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photograph or video evidence of abatement or other written records.  YC52 LLC, WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD 29 CFR 1910.107(c)(7) WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 1469277, CITATION NUMBER 1, ITEM NUMBER 1g, AND WAS AFFIRMED AS A FINAL ORDER ON SEPTEMBER 30, 2020, WITH RESPECT TO A WORKPLACE LOCATED AT 2497 FELTON RD, EAST NORRITON PA.
Recent events (1)
  • — Z (R) $0

1910.107 D04

Repeat Gravity 5 1 instance 2 exposed
Issued
May 25, 2021
Abate by
Jun 21, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.107(d)(4):The fan-rotating element was not nonferrous or nonsparking or such material did not comprise or line the casing:  a) Spray Booth: On or about February 26, 2021, employees spray paint wooden bats with flammable stains and coatings. The rotating fan blades for the ventilation system were made of a ferrous material thus exposing employees to a potential fire hazard.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.  Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photograph or video evidence of abatement or other written records.  YC52 LLC, WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD 29 CFR 1910.107(d)(4) WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 1469277, CITATION NUMBER 1, ITEM NUMBER 1h, AND WAS AFFIRMED AS A FINAL ORDER ON SEPTEMBER 30, 2020, WITH RESPECT TO A WORKPLACE LOCATED AT 2497 FELTON RD, EAST NORRITON PA.
Recent events (1)
  • — Z (R) $0

1910.107 D05

Repeat Gravity 5 1 instance 2 exposed
Issued
May 25, 2021
Abate by
Jun 21, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.107(d)(5):Electric motor(s) driving exhaust fan(s) for spray booth(s) were located inside the duct(s):  a) Spray Booth: On or about February 26, 2021, employees  spray paint wooden bats with flammable stains and coatings. An electrical motor was located in the duct work which was not of the correct classification for operation in a flammable environment.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.  Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photograph or video evidence of abatement or other written records.  YC52 LLC, WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD 29 CFR 1910.107(d)(5) WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 1469277, CITATION NUMBER 1, ITEM NUMBER 1i, AND WAS AFFIRMED AS A FINAL ORDER ON SEPTEMBER 30, 2020, WITH RESPECT TO A WORKPLACE LOCATED AT 2497 FELTON RD, EAST NORRITON PA.
Recent events (1)
  • — Z (R) $0

1910.107 D07

Repeat Gravity 5 1 instance 2 exposed
Issued
May 25, 2021
Abate by
Jun 21, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.107(d)(7):Exhaust ducts were not constructed of steel:  a) Spray Booth: On or about February 26, 2021, employees that spray paint wooden bats with flammable stains and coatings were exposed to a fire hazard in that the exhaust duct for the fans was constructed of plastic.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.  Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photograph or video evidence of abatement or other written records.  YC52 LLC, WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD 29 CFR 1910.107(d)(7) WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 1469277, CITATION NUMBER 1, ITEM NUMBER 1j, AND WAS AFFIRMED AS A FINAL ORDER ON SEPTEMBER 30, 2020, WITH RESPECT TO A WORKPLACE LOCATED AT 2497 FELTON RD, EAST NORRITON PA.
Recent events (1)
  • — Z (R) $0

1910.134 C

Repeat Gravity 1 1 instance 2 exposed
Issued
May 25, 2021
Abate by
Jun 21, 2021
Penalty
Initial $4,681 · Current $4,681
29 CFR  1910.134(c):The employer did not develop and implement a written respiratory protection program with required worksite-specific procedures and elements for required respirator use:  a) Facility: On or about February 26, 2021, the employer did not develop a written respiratory protection program for employees wearing elastomeric 3M respirators while performing spray painting of wooden bats with flammable stains.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.  Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photograph or video evidence of abatement or other written records.  YC52 LLC, WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD 29 CFR 1910.134(c) WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 1469277, CITATION NUMBER 1, ITEM NUMBER 2a, AND WAS AFFIRMED AS A FINAL ORDER ON SEPTEMBER 30, 2020, WITH RESPECT TO A WORKPLACE LOCATED AT 2497 FELTON RD, EAST NORRITON PA.
Recent events (1)
  • — Z (R) $4681

1910.134 K

Repeat Gravity 1 1 instance 2 exposed
Issued
May 25, 2021
Abate by
Jun 21, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.134(k):The employer did not provide comprehensive, understandable training which did not occur annually and/or more often if necessary:  a) Facility: On or about February 26, 2021, the employer did not provide training to employees who wear 3M elastomeric respirators while performing spray painting of bats with flammable stains and coatings.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.  Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photograph or video evidence of abatement or other written records.  YC52 LLC, WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD 29 CFR 1910.134(k) WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 1469277, CITATION NUMBER 1, ITEM NUMBER 2b, AND WAS AFFIRMED AS A FINAL ORDER ON SEPTEMBER 30, 2020, WITH RESPECT TO A WORKPLACE LOCATED AT 2497 FELTON RD, EAST NORRITON PA.
Recent events (1)
  • — Z (R) $0

1910.1200 E01

Repeat Gravity 1 1 instance 2 exposed
Issued
May 25, 2021
Abate by
Jun 21, 2021
Penalty
Initial $4,681 · Current $4,681
29 CFR  1910.1200(e)(1):The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  a) Facility: On or about February 26, 2021, employees performed a variety of tasks where they were exposed to hazardous chemicals, such as, but not limited to flammable paints and finishes and the employer did not develop and implement a written hazard communication program in accordance with this section.  ABATEMENT NOTE: A written program shall include descriptions of how the criteria for the following will be met:  1.  Labeling and other forms of warning; 2.  Safety Data Sheets; 3.  Employee information and training.   Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.  Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photograph or video evidence of abatement or other written records.  YC52 LLC, WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD 29 CFR 1910.1200(e)(1) WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 1469277, CITATION NUMBER 1, ITEM NUMBER 3a, AND WAS AFFIRMED AS A FINAL ORDER ON SEPTEMBER 30, 2020, WITH RESPECT TO A WORKPLACE LOCATED AT 2497 FELTON RD, EAST NORRITON PA.
Recent events (1)
  • — Z (R) $4681

1910.1200 H01

Repeat Gravity 1 1 instance 2 exposed
Issued
May 25, 2021
Abate by
Jun 21, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.1200(h)(1):Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  a) Facility: On or about February 26, 2021, employees performed a variety of tasks where they were exposed to hazardous chemicals, such as, but not limited to flammable paints and finishes  and the employer did not properly train employees on the hazards of chemicals in accordance with this section.  ABATEMENT NOTE: Employees shall be informed of the following: 1.  The requirements of this section; 2.  Any operations where hazardous chemicals are present; 3.  The location and availability of the written Hazard Communication Program, list(s) of hazardous chemicals and Safety Data Sheets.  Employee training shall include at least: 1.  Methods and observations that may be used to detect the presence or release of hazardous chemical in the work area. 2.  The physical, health, simple asphyxiation, combustible dust, and pyrophoric gas hazards, as well as hazards not otherwise classified, of the chemicals in the work area. 3.  The measures employees can take to protect themselves such as specific procedures and personal, protective equipment to be used. 4.  The details of the employer's Hazard Communication Program including an explanation of the labels received on shipped containers and the workplace labeling system used by the employer; Safety Data Sheets, including the order of information and how employees can obtain and use the appropriate hazard information.    Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.  Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photograph or video evidence of abatement or other written records.  YC52 LLC, WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD 29 CFR 1910.1200(h)(1) WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 1469277, CITATION NUMBER 1, ITEM NUMBER 3b, AND WAS AFFIRMED AS A FINAL ORDER ON SEPTEMBER 30, 2020, WITH RESPECT TO A WORKPLACE LOCATED AT 2497 FELTON RD, EAST NORRITON PA.