VANCOUVER, WA —
OSHA Inspection: ADVANCED AMERICAN CONSTRUCTION, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ADVANCED AMERICAN CONSTRUCTION, INC. in PORT OF VANCOUVER 100 COLUMBIA ST., VANCOUVER, WA 98660 (NAICS 237990). OSHA activity number 345167498.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ADVANCED AMERICAN CONSTRUCTION, INC.
- Site address
- PORT OF VANCOUVER 100 COLUMBIA ST.
- City
- VANCOUVER
- State
- WA
- ZIP
- 98660
- Mailing
- P.O. BOX 83599, PORTLAND, OR 97231
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237990
- Employees
- 50
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.605 B02
- Issued
- May 28, 2021
- Penalty
- Initial $3,481 · Current $2,611 Reduced
General-duty citation text
29 CFR 1926.605(b)(2): Unless employees can step safely to or from the wharf, float, barge, or river towboat, either a ramp, meeting the requirements of paragraph (b)(1) of this section, or a safe walkway, was not provided. (a) Port of Vancouver - Robishaw Flexifloat sectional barge crane access - On or about February 25, 2021 and at times prior thereto, employees were exposed to falling into the water while transiting from the pier to the barge crane (Manitowoc model 4100W serial 413419) in that the wooden decking had standing water and was slippery. The wooden platform was affected by the tide and river traffic, which also made the platform unstable.
Recent events (2)
- — I (S) $2610.75
- — Z (S) $3481
1926.151 D03
- Issued
- May 28, 2021
- Abate by
- Jun 21, 2021
- Penalty
- Initial $3,481 · Current $2,611 Reduced
General-duty citation text
29 CFR 1926.151(d)(3): Noncompatible materials, which may create a fire hazard, were not segregated by a barrier having a fire resistance of at least 1 hour. (a) Robishaw Flexifloat Sectional Barge - Fuel storage room - On or about February 25, 2021 and at times prior thereto, employees were exposed to fire and smoke inhalation in that sodium hypochlorite was stored in the fuel storage room where numerous flammables are located to include, but not limited to: diesel, gasoline, motor oil, automatic transmission fluid, aerosol paints etc.
Recent events (2)
- — I (S) $2610.75
- — Z (S) $3481
1926.152 B04 VII
- Issued
- May 28, 2021
- Abate by
- Jun 21, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.152(b)(4)(vii): In every inside storage room, one clear aisle at least 3 feet wide was not maintained. Containers over 30 gallons capacity shall not be stacked one upon the other. (a) Robishaw Flexifloat Sectional Barge- Fuel storage room - On or about February 25, 2021 and at times prior thereto, employees were exposed to fire and smoke inhalation in that there was not a 3' wide clear aisle to egress from the fuel storage room in the event of an emergency.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1412 D01 XII
- Issued
- May 28, 2021
- Abate by
- Jun 21, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1412(d)(1)(xii): Operator cab overhead window had significant cracks, breaks, or other deficiencies that would hamper the operator's view. (a) DW4100 Manitowoc crane (Serial No. 413419) - On or about February 25, 2021 and at times prior thereto, the overhead operator cab window had a large crack that was likely to hamper the operator's view.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.403 B02
- Issued
- May 28, 2021
- Abate by
- Jun 21, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.403(b)(2): Installation and use. Listed, labeled, or certified equipment were not installed and used in accordance with instructions included in the listing, labeling, or certification. (a) DB 4100 derrick barge (Robishaw Flexifloat) - Lunch Room - On or about February 25, 2021 and at times prior thereto, employees were exposed to electrical shock, fire and smoke inhalations from the improper installation and usage of a Bilkin relocatable power tap (RPT) 15 Amps in that the Magic Chef Microwave 13.5 Amps (model: MCM990ST, serial no: 0629890800454) UL Listed 54NJ and the Toastmaster Toaster 8.5 amps (model T2020WT) UL Listed 485F were both connected to the Bilkin RPT.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Advanced American Construction, INC.
View Advanced American Construction, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 237990)
More inspections in WA
Source