Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ADVANCED AMERICAN CONSTRUCTION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ADVANCED AMERICAN CONSTRUCTION, INC. in PORT OF VANCOUVER 100 COLUMBIA ST., VANCOUVER, WA 98660 (NAICS 237990). OSHA activity number 345167498.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Advanced American Construction, INC. — free Get an email when a new federal OSHA severe-injury report for Advanced American Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
PORT OF VANCOUVER 100 COLUMBIA ST.
City
VANCOUVER
State
WA
ZIP
98660
Mailing
P.O. BOX 83599, PORTLAND, OR 97231
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237990
Employees
50
Ownership type
A

5 citations on file for this inspection.

1926.605 B02

Serious Gravity 1 1 instance 8 exposed
Issued
May 28, 2021
Penalty
Initial $3,481 · Current $2,611 Reduced
29 CFR  1926.605(b)(2): Unless employees can step safely to or from the wharf, float, barge, or river towboat, either a ramp, meeting the requirements of paragraph (b)(1) of this section, or a safe walkway, was not provided.  (a) Port of Vancouver - Robishaw Flexifloat sectional barge crane access - On or about February 25, 2021 and at times prior thereto, employees were exposed to falling into the water while transiting from the pier to the barge crane (Manitowoc model 4100W serial 413419) in that the wooden decking had standing water and was slippery. The wooden platform was affected by the tide and river traffic, which also made the platform unstable.
Recent events (2)
  • — I (S) $2610.75
  • — Z (S) $3481

1926.151 D03

Serious Gravity 1 1 instance 8 exposed
Issued
May 28, 2021
Abate by
Jun 21, 2021
Penalty
Initial $3,481 · Current $2,611 Reduced
29 CFR  1926.151(d)(3): Noncompatible materials, which may create a fire hazard, were not segregated by a barrier having a fire resistance of at least 1 hour.  (a) Robishaw Flexifloat Sectional Barge - Fuel storage room - On or about February 25, 2021 and at times prior thereto, employees were exposed to fire and smoke inhalation in that sodium hypochlorite was stored in the fuel storage room where numerous flammables are located to include, but not limited to: diesel, gasoline, motor oil, automatic transmission fluid, aerosol paints etc.
Recent events (2)
  • — I (S) $2610.75
  • — Z (S) $3481

1926.152 B04 VII

Serious Gravity 1 1 instance 8 exposed
Issued
May 28, 2021
Abate by
Jun 21, 2021
Penalty
Initial $0 · Current $0
29 CFR  1926.152(b)(4)(vii): In every inside storage room, one clear aisle at least 3 feet wide was not maintained.  Containers over 30 gallons capacity shall not be stacked one upon the other.  (a) Robishaw Flexifloat Sectional Barge- Fuel storage room - On or about February 25, 2021 and at times prior thereto, employees were exposed to fire and smoke inhalation in that there was not a 3' wide clear aisle to egress from the fuel storage room in the event of an emergency.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1412 D01 XII

Other-than-serious 1 instance 1 exposed
Issued
May 28, 2021
Abate by
Jun 21, 2021
Penalty
Initial $0 · Current $0
29 CFR  1926.1412(d)(1)(xii): Operator cab overhead window had significant cracks, breaks, or other deficiencies that would hamper the operator's view.  (a) DW4100 Manitowoc crane (Serial No. 413419)  - On or about February 25, 2021 and at times prior thereto, the overhead operator cab window had a large crack that was likely to hamper the operator's view.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.403 B02

Other-than-serious 1 instance 8 exposed
Issued
May 28, 2021
Abate by
Jun 21, 2021
Penalty
Initial $0 · Current $0
29 CFR  1926.403(b)(2): Installation and use. Listed, labeled, or certified equipment were not installed and used in accordance with instructions included in the listing, labeling, or certification.  (a) DB 4100 derrick barge  (Robishaw Flexifloat) - Lunch Room - On or about February 25, 2021 and at times prior thereto, employees were exposed to electrical shock, fire and smoke inhalations from the improper installation and usage of  a Bilkin relocatable power tap (RPT) 15 Amps in that the Magic Chef Microwave 13.5 Amps (model: MCM990ST, serial no: 0629890800454)  UL Listed 54NJ and the Toastmaster Toaster 8.5 amps (model T2020WT) UL Listed 485F were both connected to the Bilkin RPT.
Recent events (2)