BRADENTON, FL —
OSHA Inspection: A&A MASONRY AND WATERPROOF, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of A&A MASONRY AND WATERPROOF, INC. in 11740 S.R. 64 EAST, BRADENTON, FL 34212 (NAICS 238140). OSHA activity number 345181754.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- A&A MASONRY AND WATERPROOF, INC.
- Site address
- 11740 S.R. 64 EAST
- City
- BRADENTON
- State
- FL
- ZIP
- 34212
- Mailing
- 5348 JUBILOSO DRIVE, SAINT CLOUD, FL 34771
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 6
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.1053 B01
- Issued
- Jun 23, 2021
- Penalty
- Initial $2,926 · Current $2,926
General-duty citation text
29 CFR 1926.1053(b)(1): Where a portable ladder was used for access to an upper level landing surface the ladders length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder. a) For employees working at the location as observed on or about 3 March, 2021. Employees were accessing the upper working level by a single ladder that did not have the side rails extended at least 3 feet above the upper landing surface and the grasping device in use was a 5/8 inch piece of rebar that was approximately 36 inches in height. The grasping device was not sufficient in strength to prevent the employees from a fall.
Recent events (1)
- — Z (S) $2926
1926.1060 A
- Issued
- Jun 23, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1060(a): The employer shall provide a training program for each employee using ladders and stairways, as necessary. The program shall enable each employee to recognize hazards related to ladders and stairways, and shall train each employee in the procedures to be followed to minimize these hazards. a) For employees working at the location as observed on or about 3 March, 2021. Employees were accessing the upper working level by a single ladder that did not have the side rails extended at least 3 feet above the upper landing surface and the grasping device in use was a 5/8 inch piece of rebar that was approximately 36 inches in height. The grasping device was not sufficient in strength to prevent the employees from a fall. The employer failed to provide proof of required training.
Recent events (1)
- — Z (S) $0
More inspections at A&A Masonry and Waterproof, INC.
View A&A Masonry and Waterproof, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345181754.