Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SAMUEL LEDESMA SANCHEZ

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SAMUEL LEDESMA SANCHEZ in (LOT #53) 2216 SWANSEA WAY, SMYRNA, GA 30080 (NAICS 238130). OSHA activity number 345197776.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Samuel Ledesma Sanchez — free Get an email when a new federal OSHA severe-injury report for Samuel Ledesma Sanchez is published. One employer, no account, unsubscribe in one click.
Site address
(LOT #53) 2216 SWANSEA WAY
City
SMYRNA
State
GA
ZIP
30080
Mailing
1090 WHITE HEAD CIRCLE, SUGAR HILL, GA 30518
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
3
Ownership type
A

4 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 15, 2021
Abate by
Apr 27, 2021
Penalty
Initial $2,341 · Current $2,341
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles.  New residential construction located on Lot #53, Top plates: On or about 03/15/2021, the employer exposed employees to struck-by hazards while operating pneumatic nail guns, in that protective eyewear was not provided to employees engaged in roof truss installation.
Recent events (1)
  • — Z (S) $2341

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Apr 15, 2021
Penalty
Initial $4,096 · Current $4,096
29 CFR  1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m)  or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501(b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:    New residential construction located on Lot #53, Top plates: On or about 03/15/2021, the employer exposed employees to fall hazards of 22-feet, 1-inch to the lower level, in that a fall protection system was not provided to employees using the top plates as a walking/working surface to set new roof trusses.
Recent events (1)
  • — Z (S) $4096

1926.1053 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 15, 2021
Penalty
Initial $2,341 · Current $2,341
29 CFR  1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:   New residential construction located on Lot #53, Rough opening for stairwell between first and second floors: On or about 03/15/2021, the employer exposed employees to fall hazards of 11-feet, 3-inches to the lower concrete slab, in that a ladder which extended at least 3-feet past the second floor landing was not provided to allow safe access on and off the second level.
Recent events (1)
  • — Z (S) $2341

1926.403 B01

Other-than-serious 1 instance 1 exposed
Issued
Apr 15, 2021
Abate by
Apr 27, 2021
Penalty
Initial $0 · Current $0
29 CFR  1926.403(b)(1): Employer did not ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees:ALLEGED VIOLATION DESCRIPTION (A.V.D.):    New residential construction located on Lot #53,  Temporary electrical service box: On or about 03/15/2021, the employer failed to inspect electrical equipment including extension cords and electric air compressor, in that flexible cords were missing ground pins and the compressor used had live circuits protruding from the motor compartment creating a potential shock hazard if not removed or repaired.