BUDA, TX —
OSHA Inspection: RESIDENTIAL DESIGN SERVICES
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of RESIDENTIAL DESIGN SERVICES in 266 COMMERCIAL DRIVE, BUDA, TX 78610 (NAICS 327991). OSHA activity number 345214878.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RESIDENTIAL DESIGN SERVICES
- Site address
- 266 COMMERCIAL DRIVE
- City
- BUDA
- State
- TX
- ZIP
- 78610
- Mailing
- 266 COMMERCIAL DRIVE, BUDA, TX 78610
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327991
- Employees
- 30
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.147 C01
- Issued
- Jun 22, 2021
- Abate by
- Jul 19, 2021
- Penalty
- Initial $9,557 · Current $5,734 Reduced
General-duty citation text
29 CFR 1910.147(c)(1):The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative. On or about March 24, 2021, employees were performing maintenance on machines within the facility without the employer establishing and implementing a lockout tagout program, exposing employees to hazards such as, but not limited to the release of stored energy and unexpected startup.
Recent events (2)
- — I (S) $5734.2
- — Z (S) $9557
1910.147 D04 I
- Issued
- Jun 22, 2021
- Abate by
- Jul 19, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(4)(i):Lockout or tagout devices were not affixed to each energy isolating device by authorized employees. On or about March 24, 2021, employees were performing maintenance on machines within the facility without the use of locks or tags, exposing employees to hazards such as, but not limited to the release of stored energy and unexpected startup.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.179 J02
- Issued
- Jun 22, 2021
- Abate by
- Jul 19, 2021
- Penalty
- Initial $5,461 · Current $3,277 Reduced
General-duty citation text
29 CFR 1910.179(j)(2): Overhead cranes were not inspected for defects on a daily basis for items including but not limited to; all functional operating mechanisms for maladjustment, deterioration or leakage of air or hydraulic systems and hooks: On or about March 24, 2021, employees were operating multiple cranes on the production floor without the employer ensuring the cranes have been inspected for damage or malfunction on a daily basis, exposing employees to hazards such as, but not limited to being stuck by the cranes, crane attachments and by materials the crane is handling.
Recent events (2)
- — I (S) $3276.6
- — Z (S) $5461
1910.179 J03
- Issued
- Jun 22, 2021
- Abate by
- Jul 19, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.179(j)(3):A complete periodic inspection of crane(s) had not been conducted in the past 12 months:(a)(LOCATION OF CRANE)(IDENTIFICATION AND TYPE OF CRANE)(DESCRIBE SPECIFIC CONDITION(S) AND HAZARD(S)) On or about March 24, 2021, employees were operating multiple cranes on the production floor without the employer ensuring the cranes have been inspected for damage or malfunction on a annual basis, exposing employees to hazards such as, but not limited to being stuck by the cranes, crane attachments and by materials the crane is handling.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B02 I
- Issued
- Jun 22, 2021
- Penalty
- Initial $5,461 · Current $3,277 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i):Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy. On or about March 24, 2021, and at times prior thereto, employees were in close proximity to 120 volt electrical outlets that did not have faceplates, exposing the employees to the hazard of being electrically shocked.
Recent events (2)
- — I (S) $3276.6
- — Z (S) $5461
1910.334 A04
- Issued
- Jun 22, 2021
- Abate by
- Jun 28, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(4):Portable electric equipment and flexible cords used in highly conductive work locations, or in job locations where employees were likely to contact water or conductive liquids, were not approved for those locations: On or about March 24, 2021, and at times prior thereto, employees were working in close proximity to electric equipment with power cords that were in contact with water, exposing the employees to the hazard of being electrically shocked.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Residential Design Services
View Residential Design Services's full OSHA safety record →
More inspections in this industry (NAICS 327991)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345214878.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.