Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: J.F. AHERN CO.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of J.F. AHERN CO. in N5585 COUNTY ROAD N, ARKANSAW, WI 54721 (NAICS 238220). OSHA activity number 345219729.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch J.F. Ahern CO. — free Get an email when a new federal OSHA severe-injury report for J.F. Ahern CO. is published. One employer, no account, unsubscribe in one click.
Establishment
J.F. AHERN CO.
Site address
N5585 COUNTY ROAD N
City
ARKANSAW
State
WI
ZIP
54721
Mailing
5315 FREITAG DRIVE, MENOMONIE, WI 54751
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
4
Ownership type
A

2 citations on file for this inspection.

1926.451 B02 II

Deleted Serious Gravity 1 1 instance 2 exposed
Issued
Jun 21, 2021
Abate by
Jul 13, 2021
Penalty
Initial $3,949 · Current $0 Reduced
29 CFR  1926.451(b)(2)(ii): Where scaffolds must be used in areas that the employer can demonstrate are so narrow that platforms and walkways cannot be at least 18 inches (46 cm) wide, such platforms and walkways were not as wide as feasible:  (a) In the vehicle storage garage; Employees were using the 1.25 inch wide midrail of a SkyJack Model SJ6826RJ scissor lift as a work platform to access overhead areas in order to install hangers for ventilation piping.  The work platform was not as wide as feasible due to alternative equipment and/or methods available.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3949

1926.451 F01

Deleted Serious Gravity 1 1 instance 2 exposed
Issued
Jun 21, 2021
Abate by
Jul 13, 2021
Penalty
Initial $0 · Current $0
29 CFR  1926.451(f)(1): Scaffold and/or scaffold components were loaded in excess of their maximum intended loads or rated capacities, whichever was less:  (a) In the newly constructed vehicle storage garage; Employees were using the 1.25 inch wide midrail of a SkyJack Model SJ6826RJ scissor lift as a work platform to install hangers for ventilation piping.  According to the manufacturer, Skyjack scissor lifts guardrails are not intended or rated for supporting personnel.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View J.F. Ahern CO.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345219729.