ARKANSAW, WI —
OSHA Inspection: J.F. AHERN CO.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of J.F. AHERN CO. in N5585 COUNTY ROAD N, ARKANSAW, WI 54721 (NAICS 238220). OSHA activity number 345219729.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- J.F. AHERN CO.
- Site address
- N5585 COUNTY ROAD N
- City
- ARKANSAW
- State
- WI
- ZIP
- 54721
- Mailing
- 5315 FREITAG DRIVE, MENOMONIE, WI 54751
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238220
- Employees
- 4
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.451 B02 II
- Issued
- Jun 21, 2021
- Abate by
- Jul 13, 2021
- Penalty
- Initial $3,949 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(b)(2)(ii): Where scaffolds must be used in areas that the employer can demonstrate are so narrow that platforms and walkways cannot be at least 18 inches (46 cm) wide, such platforms and walkways were not as wide as feasible: (a) In the vehicle storage garage; Employees were using the 1.25 inch wide midrail of a SkyJack Model SJ6826RJ scissor lift as a work platform to access overhead areas in order to install hangers for ventilation piping. The work platform was not as wide as feasible due to alternative equipment and/or methods available.
Recent events (2)
- — I (S) $0
- — Z (S) $3949
1926.451 F01
- Issued
- Jun 21, 2021
- Abate by
- Jul 13, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(1): Scaffold and/or scaffold components were loaded in excess of their maximum intended loads or rated capacities, whichever was less: (a) In the newly constructed vehicle storage garage; Employees were using the 1.25 inch wide midrail of a SkyJack Model SJ6826RJ scissor lift as a work platform to install hangers for ventilation piping. According to the manufacturer, Skyjack scissor lifts guardrails are not intended or rated for supporting personnel.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at J.F. Ahern CO.