Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SOUTHERN FOREST PRODUCTS, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SOUTHERN FOREST PRODUCTS, LLC in 181 COUNTY RD 2012, NEWTON, TX 75966 (NAICS 321113). OSHA activity number 345223762.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Southern Forest Products, LLC — free Get an email when a new federal OSHA severe-injury report for Southern Forest Products, LLC is published. One employer, no account, unsubscribe in one click.
Site address
181 COUNTY RD 2012
City
NEWTON
State
TX
ZIP
75966
Mailing
181 COUNTY RD 2012, NEWTON, TX 75966
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321113
Employees
50
Ownership type
A

2 citations on file for this inspection.

1910.265 C26 IX

Serious Gravity 5 1 instance 2 exposed
Issued
May 3, 2021
Abate by
May 20, 2021
Penalty
Initial $9,011 · Current $5,407 Reduced
29 CFR  1910.265(c)(26)(ix):Every stacker and unstacker shall be inspected at frequent intervals and all defective parts shall be immediately repaired or replaced.  On or about March 30, 2021, and at times prior thereto, at the stacker where employees were exposed to a struck-by hazard when working without all known defective parts being immediately repaired or replaced.
Recent events (2)
  • — I (S) $5406.6
  • — Z (S) $9011

1910.303 G02 I

Serious Gravity 10 1 instance 1 exposed
Issued
May 3, 2021
Penalty
Initial $10,513 · Current $6,308 Reduced
29 CFR  1910.303(g)(2)(i):Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):  On or about March 30, 2021, and at times prior thereto, at the stacker where employees were exposed to an electrocution hazard when operating the unit without all live parts of the electrical breaker cabinet being guarded.
Recent events (2)
  • — I (S) $6307.8
  • — Z (S) $10513

View Southern Forest Products, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345223762.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.