FREDERICK, CO —
OSHA Inspection: DIAMOND SPAS, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of DIAMOND SPAS, INC. in 4409 CORIOLIS WAY, FREDERICK, CO 80504 (NAICS 332510). OSHA activity number 345243323.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DIAMOND SPAS, INC.
- Site address
- 4409 CORIOLIS WAY
- City
- FREDERICK
- State
- CO
- ZIP
- 80504
- Mailing
- 4409 CORIOLIS WAY, FREDERICK, CO 80504
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- Yes
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332510
- Employees
- 47
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.22 A01
- Issued
- Aug 12, 2021
- Abate by
- Aug 24, 2021
- Penalty
- Initial $4,096 · Current $2,458 Reduced
General-duty citation text
29 CFR 1910.22(a)(1):Floor aisles and passageways were not kept clear creating trip hazards in the workplace. a) Diamond Spas, Inc. 4409 Coriolis Way, Frederick, CO 80504: On and before April 9, 2021, the employer did not ensure the walking/working area in the production area were free from tripping and slipping hazards, in that electrical cords are not kept in an orderly manner. Employees are exposed to slip and trip hazards. This condition exposed employees to broken bones.
Recent events (2)
- — I (S) $2457.6
- — Z (S) $4096
1910.144 A01 III
- Issued
- Aug 12, 2021
- Abate by
- Aug 24, 2021
- Penalty
- Initial $5,461 · Current $3,277 Reduced
General-duty citation text
29 CFR 1910.144(a)(1)(iii):Emergency stop bars, stop buttons or switches which letters or other markings appear, used for emergency stopping of machinery were not red: a) Diamond Spas, Inc. 4409 Coriolis Way, Frederick, CO 80504: On and before April 9, 2021, the employer did not ensure that the estop on the Cincinnati CNC Laser cutter was red and in working order. This condition exposed employees to broken arms, hands and fingers.
Recent events (2)
- — I (S) $3276.6
- — Z (S) $5461
1910.147 C01
- Issued
- Aug 12, 2021
- Abate by
- Aug 24, 2021
- Penalty
- Initial $5,461 · Current $3,277 Reduced
General-duty citation text
29 CFR 1910.147(c)(1):The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) Diamond Spas, Inc. 4409 Coriolis Way, Frederick, CO 80504: On and before February 23, 2021, the employer did not establish a program consisting of energy control procedures and employee training to ensure that before any employee performed any servicing or maintenance machinery including but not limited to the Maxiem Waterjet Model 1530. The condition exposed employees to caught in, struck-by and electrical hazards.
Recent events (2)
- — I (S) $3276.6
- — Z (S) $5461
1910.147 C04 I
- Issued
- Aug 12, 2021
- Abate by
- Aug 24, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(i):Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Diamond Spas, Inc. 4409 Coriolis Way, Frederick, CO 80504: On and before February 23, 2021, machine specific, step-by-step procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in maintenance on machinery including but not limited to the Maxiem Waterjet Model 1530. The condition exposed employees to caught in, struck-by and electrical hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 G01 II
- Issued
- Aug 12, 2021
- Abate by
- Aug 24, 2021
- Penalty
- Initial $8,192 · Current $4,915 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: a) Diamond Spas, Inc. 4409 Coriolis Way, Frederick, CO 80504: On and before April 9, 2021, the employer did not maintain a workspace of at least 3 feet in front of an electrical panel located on the wall in the welding department. Hand tools and welding equipment were located in front of electrical panels in the welding area. This condition exposed employees to electrical hazards.
Recent events (2)
- — I (S) $4915.2
- — Z (S) $8192
More inspections at Diamond Spas, INC.
View Diamond Spas, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332510)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345243323.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.