Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CTPS LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CTPS LLC in 3 GRANDE BOULEVARD, SARATOGA SPRINGS, NY 12866 (NAICS 561910). OSHA activity number 345255376.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ctps LLC — free Get an email when a new federal OSHA severe-injury report for Ctps LLC is published. One employer, no account, unsubscribe in one click.
Establishment
CTPS LLC
Site address
3 GRANDE BOULEVARD
City
SARATOGA SPRINGS
State
NY
ZIP
12866
Mailing
810 HIDDEN CAVE ROAD, MADISON, WI 53717
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561910
Employees
223
Ownership type
A

5 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 24, 2021
Abate by
Aug 30, 2021
Penalty
Initial $7,461 · Current $4,850 Reduced
29 CFR  1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  a) Pallet Area of Machine 2 - On or about April 14, 2021 an employee was exposed to caught-in hazards due to performing cleaning operations when going into the machine with a Shop Vac to clean out dirt and debris without utilizing the lockout/tagout procedure.
Recent events (2)
  • — I (S) $4849.65
  • — Z (S) $7461

1910.212 A01

Serious Gravity 5 2 instances 2 exposed
Issued
Aug 24, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a) Light Curtain Area on Machine 1 - On or prior to April 16, 2021, employees  operating Machine 1 (Make: Canconex, Model: Sort Pro Series 2 Model # SP017, Serial Number: 1620) were exposed to caught-in hazards due there being no guarding installed next to the light curtain area.   b) Light Curtain Area on Machine 2 - On or prior to April 16, 2021, employees  operating Machine 2 (Make: Canconex, Model: Sort Pro Series 2 Model # SP017, Serial Number: 2751) were exposed to caught-in hazards due there being no guarding installed next to the light curtain area.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 H01

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 24, 2021
Penalty
Initial $8,953 · Current $5,819 Reduced
29 CFR  1910.219(h)(1):Projecting key(s), setscrew(s), or other projections in revolving part(s) were not removed, made flush, or guarded by metal cover(s):  a) Machine 2 in area where operator primarily stands to operate machine - On or about  April 16, 2021,  Machine 2 (Make: Canconex, Model: Sort Pro Series 2 Model # SP017, Serial Number: 2751) had a rotating bearing with projecting setscrews or other projections that were not adequately guarded exposing the operator employee to caught-in hazards.
Recent events (2)
  • — I (S) $5819.45
  • — Z (S) $8953

1910.305 B01 II

Other-than-serious 1 instance 4 exposed
Issued
Aug 24, 2021
Abate by
Oct 12, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.305(b)(1)(ii):Unused openings in boxes, cabinets, or fittings were not effectively closed:  a) Facility - On or about April 16, 2021, there were missing knockout plugs on the control panels for Machine 1 and Machine 2, as well as missing knockout plugs on the electrical panels and boxes on the wall near Machine 1 and 2.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G01 IV A

Other-than-serious 1 instance 1 exposed
Issued
Aug 24, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.305(g)(1)(iv)(A):Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a) Machine 2 - On or prior to April 16, 2021, an extension cord was being used as permanent wiring to power a light for Machine 2 (Make: Canconex, Model: Sort Pro Series 2 Model # SP017, Serial Number: 2751).