SARATOGA SPRINGS, NY —
OSHA Inspection: CTPS LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of CTPS LLC in 3 GRANDE BOULEVARD, SARATOGA SPRINGS, NY 12866 (NAICS 561910). OSHA activity number 345255376.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CTPS LLC
- Site address
- 3 GRANDE BOULEVARD
- City
- SARATOGA SPRINGS
- State
- NY
- ZIP
- 12866
- Mailing
- 810 HIDDEN CAVE ROAD, MADISON, WI 53717
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561910
- Employees
- 223
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.147 C04 I
- Issued
- Aug 24, 2021
- Abate by
- Aug 30, 2021
- Penalty
- Initial $7,461 · Current $4,850 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Pallet Area of Machine 2 - On or about April 14, 2021 an employee was exposed to caught-in hazards due to performing cleaning operations when going into the machine with a Shop Vac to clean out dirt and debris without utilizing the lockout/tagout procedure.
Recent events (2)
- — I (S) $4849.65
- — Z (S) $7461
1910.212 A01
- Issued
- Aug 24, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Light Curtain Area on Machine 1 - On or prior to April 16, 2021, employees operating Machine 1 (Make: Canconex, Model: Sort Pro Series 2 Model # SP017, Serial Number: 1620) were exposed to caught-in hazards due there being no guarding installed next to the light curtain area. b) Light Curtain Area on Machine 2 - On or prior to April 16, 2021, employees operating Machine 2 (Make: Canconex, Model: Sort Pro Series 2 Model # SP017, Serial Number: 2751) were exposed to caught-in hazards due there being no guarding installed next to the light curtain area.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 H01
- Issued
- Aug 24, 2021
- Penalty
- Initial $8,953 · Current $5,819 Reduced
General-duty citation text
29 CFR 1910.219(h)(1):Projecting key(s), setscrew(s), or other projections in revolving part(s) were not removed, made flush, or guarded by metal cover(s): a) Machine 2 in area where operator primarily stands to operate machine - On or about April 16, 2021, Machine 2 (Make: Canconex, Model: Sort Pro Series 2 Model # SP017, Serial Number: 2751) had a rotating bearing with projecting setscrews or other projections that were not adequately guarded exposing the operator employee to caught-in hazards.
Recent events (2)
- — I (S) $5819.45
- — Z (S) $8953
1910.305 B01 II
- Issued
- Aug 24, 2021
- Abate by
- Oct 12, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii):Unused openings in boxes, cabinets, or fittings were not effectively closed: a) Facility - On or about April 16, 2021, there were missing knockout plugs on the control panels for Machine 1 and Machine 2, as well as missing knockout plugs on the electrical panels and boxes on the wall near Machine 1 and 2.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G01 IV A
- Issued
- Aug 24, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A):Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) Machine 2 - On or prior to April 16, 2021, an extension cord was being used as permanent wiring to power a light for Machine 2 (Make: Canconex, Model: Sort Pro Series 2 Model # SP017, Serial Number: 2751).
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Ctps LLC
View Ctps LLC's full OSHA safety record →
More inspections in this industry (NAICS 561910)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345255376.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.