YOUNGSTOWN, OH —
OSHA Inspection: HIGH TECH MOLDING & DESIGN, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of HIGH TECH MOLDING & DESIGN, INC. in 27 WEST INDIANOLA AVENUE, YOUNGSTOWN, OH 44507 (NAICS 333511). OSHA activity number 345260855.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HIGH TECH MOLDING & DESIGN, INC.
- Site address
- 27 WEST INDIANOLA AVENUE
- City
- YOUNGSTOWN
- State
- OH
- ZIP
- 44507
- Mailing
- 27 WEST INDIANOLA AVENUE, YOUNGSTOWN, OH 44507
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333511
- Employees
- 8
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.147 C01
- Issued
- Jul 1, 2021
- Abate by
- Aug 18, 2021
- Penalty
- Initial $4,096 · Current $2,458 Reduced
General-duty citation text
29 CFR 1910.147(c)(1):Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative. On or about April 19, 2021, the employer did not establish an energy control program consisting of energy control procedures, employee training, and periodic inspections to ensure employees performing servicing and maintenance activities on the plastic injection molding machine, saws, orbit former machines, grinders, and other machines and equipment at the facility were protected from unexpected energizing, startup, or release of stored energy. Machines and equipment used throughout the facility are powered by electric, pneumatic, and hydraulic power.
Recent events (2)
- — I (S) $2458
- — Z (S) $4096
1910.178 L01 II
- Issued
- Jul 1, 2021
- Penalty
- Initial $2,341 · Current $1,405 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(ii):Prior to permitting an employee to operate a powered industrial truck (except for training purposes), the employer shall ensure that each operator has successfully completed the training required by this paragraph (l), except as permitted by paragraph (l)(5). On or about April 19, 2021, the employer did not ensure employees operating powered industrial trucks (forklifts) had successfully completed powered industrial truck safe operation training.
Recent events (2)
- — I (S) $1405
- — Z (S) $2341
1910.212 A01
- Issued
- Jul 1, 2021
- Abate by
- Aug 18, 2021
- Penalty
- Initial $2,341 · Current $1,405 Reduced
General-duty citation text
29 CFR 1910.212(a)(1):Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. On or about April 19, 2021, the employer did not ensure all portions of a Tannewitz, Type GH, Vertical Band Saw blade, except the working portion of the blade between the bottom of the guide rolls and the table, were guarded to protect operators from contacting the rotating blade.
Recent events (2)
- — I (S) $1405
- — Z (S) $2341
1910.303 F04
- Issued
- Jul 1, 2021
- Abate by
- Aug 30, 2021
- Penalty
- Initial $2,926 · Current $1,754 Reduced
General-duty citation text
29 CFR 1910.303(f)(4):Capable of accepting a lock. Disconnecting means required by this subpart shall be capable of being locked in the open position. On or about April 19, 2021, the employer did not ensure the Farrel Plastic Injection Molding Press No. 3 was equipped with a disconnecting means capable of being locked in the open position. The electrical disconnect lever was broken and/or missing from the machine.
Recent events (2)
- — I (S) $1754
- — Z (S) $2926
1910.28 B11 II
- Issued
- Jul 1, 2021
- Abate by
- Aug 18, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.28(b)(11)(ii):(ii) Each flight of stairs having at least 3 treads and at least 4 risers is equipped with stair rail systems and handrails as follows: (see TABLE D-2) On or about April 19, 2021, the employer did not ensure a flight of stairs located at the HPM Plastic Injection Molding Machine, consisting of 5 treads and 5 risers, was equipped with a stair rail system on each open side.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at High Tech Molding & Design, INC.
View High Tech Molding & Design, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 333511)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345260855.