PERRY, GA —
OSHA Inspection: ADVANCED DRAINAGE SYSTEMS, INC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ADVANCED DRAINAGE SYSTEMS, INC in 1005 VALLEY DR, PERRY, GA 31069 (NAICS 326199). OSHA activity number 345261473.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ADVANCED DRAINAGE SYSTEMS, INC
- Site address
- 1005 VALLEY DR
- City
- PERRY
- State
- GA
- ZIP
- 31069
- Mailing
- 1005 VALLEY DRIVE, PERRY, GA 31069
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 79
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C04 I
- Issued
- Aug 23, 2021
- Abate by
- Sep 17, 2021
- Penalty
- Initial $13,653 · Current $8,192 Reduced
General-duty citation text
Standard cited changed to 1910.147(c)(i) and violation to read as follows: The employer did not provide adequate training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by the employees On or about 4/19/2021, at the Sock Tucker location in the facility located on 1005 Valley Dr. , Perry, GA 31069, Employees exposed to potential hazardous energy during production or equipment malfunctions were not provided adequate training that provided the employees knowledge and skills to recognize unsafe equipment.
Recent events (2)
- — I (O) $8191.8
- — Z (S) $13653
1910.212 A02
- Issued
- Aug 23, 2021
- Abate by
- Sep 17, 2021
- Penalty
- Initial $13,653 · Current $8,192 Reduced
General-duty citation text
29 CFR 1910.212(a)(2):Guards on machine were not affixed to the machine or secured elsewhere when attachment to the machine was not possible On or about 4/19/2021, at the Sock Tucker, located at 1005 Valley Dr. in the Perry, GA facility, employees were exposed to a an amputation hazard from moving parts, when the employer failed to ensure the metal gate/access door used as guarding around the equipment was securely affixed to the machine, where possible, or fastened by any method (e.g., bolts) that prevented the guard from being inadvertently dislodged or removed.
Recent events (2)
- — I (S) $8191.8
- — Z (S) $13653
More inspections at Advanced Drainage Systems, INC
View Advanced Drainage Systems, INC's full OSHA safety record →
More inspections in this industry (NAICS 326199)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345261473.